Objective To study the accuracy of collapsed cone convolution (CCC) and anisotropic analytical algorithm (AAA) in dosimetric calculation on the air cavity interface. Methods A BEAMnrc/EGSnrc Monte Carlo (MC) simulation was performed on a Varian Trilogy linear accelerator. The IBA Dosimetry “blue phantom” 3D scanning system was used to verify the accuracy and reliability of the MC simulation. Central axis depth dose distribution and lateral dose profile in a water-equivalent phantom with variously sized air cavities were calculated by CCC and AAA. The obtained depth dose distribution and lateral dose profile were compared with those by MC simulation and EBT2 film, respectively. Results Both CCC and AAA overestimated the dose on the air cavity interface. In spite of some errors, CCC had a higher accuracy than AAA. The errors were mainly related to computational grid, field size, photon energy, cavity size, and the number of fields. Conclusion Electronic disequilibrium on the air cavity interface should be taken into account when CCC and AAA are used for dosimetric calculation in treatment planning system.
Chen Hua,Xu Yiguo,Zhuang Zhimiao et al. Dose accuracy research on air cavity interface in treatment planning system[J]. Chinese Journal of Radiation Oncology, 2017, 26(1): 69-73.
Chen Hua,Xu Yiguo,Zhuang Zhimiao et al. Dose accuracy research on air cavity interface in treatment planning system[J]. Chinese Journal of Radiation Oncology, 2017, 26(1): 69-73.
[1] Papanikolaou N,Battista JJ,Boyer AL,et al. Tissue inhomogeneity corrections for megavoltage photon beams[R].AAPM Report No.85,2004.
[2] Behrens CF.Dose build-up behind air cavities for Co-60,4,6 and 8 MV.Measurements and Monte Carlo simulations[J].Phys Med Biol,2006,51(22):5937-5950.DOI:10.1088/0031-9155/51/22/015.
[3] Petoukhova AL,Terhaard CHJ,Welleweerd H.Does 4 MV perform better compared to 6 MV in the presence of air cavities in the head and neck region[J].Radiother Oncol,2006,79(2):203-207.DOI:10.1016/j.radonc.2006.04.002.
[4] Lynch BD,Kozelka J,Ranade MK,et al. Important considerations for radiochromic film dosimetry with flatbed CCD scanners and EBT GAFCHROMICfilm[J].Med Phys,2006,33(12):4551.DOI:10.1118/1.2370505.
[5] Fuss M,Sturtewagen E,De Wagter C,et al. Dosimetric characterization of GafChromic EBT film and its implication on film dosimetry quality assurance[J].Phys Med Biol,2007,52(14):4211-4225.DOI:10.1088/0031-9155/52/14/013.
[6] Niemierko A,Goitein M.The influence of the size of the grid used for dose calculation on the accuracy of dose estimation[J].Med Phys,1989,16(2):239.DOI:10.1118/1.596419.
[7] 李建,康盛伟,祁国海,等.空腔和非均匀组织对不同照射技术的剂量学影响[J].中华放射肿瘤学杂志,2014,23(5):437-440.DOI:10.3760/cma.j.issn.1004-4221.2014.05.019.
Li J,Kang SW,Qi GH,et al. Dosimetry influence of different radiotherapy technologies caused by cavity and inhomogeneous tissues[J].Chin J Radit Oncol,2014,23(5):437-440.DOI:10.3760/cma.j.issn.1004-4221.2014.05.019.