乳腺托架固定下全乳调强放疗摆位误差兆伏X线验证平片测定分析
王健仰,王淑莲,黄鹏,张涛,李晔雄,金晶,王维虎,刘新帆,余子豪,刘跃平,宋永文,房辉,任骅,李宁
100021 北京协和医学院中国医学科学院肿瘤医院肿瘤研究所放疗科
Assessment of setup error in orthogonal megavoltage X-ray film for whole breast radiation with breast bracket immobilized
WANG Jian-yang, WANG Shu-lian, HUANG Peng, ZHANG Tao, LI Ye-xiong,JIN Jing, WANG Wei-hu, LIU Xin-fan, YU Zi-hao, LIU Yue-ping, SONG Yong-wen, FANG Hui, REN Hua, LI Ning.
Department of Radiation Oncology, Cancer Hospital (Institute), Chinese Academy of Medical Sciences,Peking Union Medical College, Beiiing 100021, China
Objective To quantify the setup errors measured with orthogonal megavoltage X-ray film in breast cancer patients immobilized in breast bracket. To probe into the margins from clinical target volume (CTV) to planning target volume (PTV) in 3 directions. Methods Repeat orthogonal megavoltage X-ray films were acquired for routine of fine setup verification in 29 breast cancer patients after conserving surgery, 17 received whole breast radiation and 12 received both whole breast and supraclavicular node radiation. All patients were immobilized in the supine position with both arms raised over their heads, using a personalized α-cradle (breast bracket). Registrations of the bony anatomy for megavoltage X-ray films to digitally reconstructed-radiographs from the planning CT were compared. Systematic and random setup errors were quantified, and the differences between groups with and without supraclavicular node radiation were compared by independent two-sample t-test. Results The mean set up deviation, systematic error and random error were (0.9±3.1) mm,(0.7±3.0) mm,(1.2±2.1) mm and 3.1 mm, 3.0 mm, 2.1 mm and 2.7 mm, 3.3 mm, 3.5 mm in the mediolateral, superoinferior and anteroposterior dimensions. There is no difference of set up deviation between patients received supraclavicular node radiation and those did not (t=0.02,0.20,0.20, P=0.98,0.85,0.85). The margins from CTV to PTV were 9.6 mm, 9.8 mm, 7.7 mm in mediolateral, superoinferior and anteroposterior directions. Conclusion For whole breast irradiation patients immobilized with breast bracket, the margins from CTV to PTV were recommended as 9.6 mm, 9.8 mm, 7.7 mm in mediolateral, superoinferior and anteroposterior directions.
WANG Jian-yang,WANG Shu-lian,HUANG Peng et al. Assessment of setup error in orthogonal megavoltage X-ray film for whole breast radiation with breast bracket immobilized[J]. Chinese Journal of Radiation Oncology, 2013, 22(3): 239-242.
[1] Pignol JP, Olivotto I, Rakovitch E, et al. A multicenter randomized trial of breast intensity-modulated radiation therapy to reduce acute radiation dermatitis. J Clin Oncol,2008,26:2085-2092. [2] Donovan E, Bleakley N, Denholm E, et al. Randomised trial of standard 2D radiotherapy (RT) versus intensity modulated radiotherapy (IMRT) in patients prescribed breast radiotherapy. Radiother Oncol,2007,82:254-264. [3] Remeijer P, Geerlof E, Ploeger L, et al. 3-D portal image analysis in clinical practice:an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients. Int J Radiat Oncol Biol Phys,2000,46:1281-1290. [4] van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage:dose-population histograms for deriving treatment margins in radiotherapy. Int J Radiat Oncol Biol Phys,2000,47:1121-1135. [5] Bel A, van Herk M, Bartelink H, et al. A verification procedure to improve patient set-up accuracy using portal images. Radiother Oncol,1993,29:253-260. [6] Lirette A, Pouliot J, Aubin M, et al. The role of electronic portal imaging in tangential breast irradiation:a prospective study. Radiother Oncol,1995,37:241-245. [7] Fein DA, McGee KP, Schultheiss TE, et al. Intra-and interfractional reproducibility of tangential breast fields:a prospective on-line portal imaging study. Int J Radiat Oncol Biol Phys,1996,34:733-740. [8] Kim LH, Wong J, Yan D. On-line localization of the lumpectomy cavity using surgical clips. Int J Radiat Oncol Biol Phys,2007,69:1305-1309. [9] Topolnjak R, van Vliet-Vroegindeweij C, Sonke JJ, et al. Breast- conserving therapy:radiotherapy margins for breast tumor bed boost. Int J Radiat Oncol Biol Phys,2008,72:941-948. [10] Topolnjak R, Sonke JJ, Nijkamp J, et al. Breast patient setup error assessment:comparison of electronic portal image devices and cone-beam computed tomography matching results. Int J Radiat Oncol Biol Phys,2010,78:1235-1243. [11] Dutreix J, Tubiana M, Dutreix A. An approach to the interpretation of clinical data on the tumour control probability-dose relationship. Radiother Oncol,1988,11:239-248. [12] Dische S, Saunders MI, Williams C, et al. Precision in reporting the dose given in a course of radiotherapy. Radiother Oncol,1993,29:287-293. [13] Remouchamps VM, Letts N, Yan D, et al. Three-dimensional evaluation of intra-and interfraction immobilization of lung and chest wall using active breathing control:a reproducibility study with breast cancer patients. Int J Radiat Oncol Biol Phys,2003,57:968-978. [14] Chopra S, Dinshaw KA, Kamble R, et al. Breast movement during normal and deep breathing, respiratory training and set up errors:implications for external beam partial breast irradiation. Br J Radiol,2006,79:766-773. [15] 刘翠翠,李建彬,范廷勇,等.锥形束CT引导自主呼吸控制保乳术后三维适形部分乳腺外照射术腔中银夹位移的研究.中华放射肿瘤学杂志,2008,17:43-46. [16] 李建彬,王巾帼,卢洁,等.自主呼吸控制对保乳术后全乳调强放疗靶区剂量分布的影响.中华放射肿瘤学杂志,2009,31:617-621. [17] Furuya T, Sugimoto S, Kurokawa C, et al. The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniques. J Radiat Res,2013,In press. [18] Topolnjak R, Borst GR, Nijkamp J, et al. Image-guided radiotherapy for left-sided breast cancer patients:geometrical uncertainty of the heart. Int J Radiat Oncol Biol Phys,2012,82:647-655. [19] Gagel B, Demirel C, Kientopf A, et al. Active breathing control (ABC):determination and reduction of breathing-induced organ motion in the chest. Int J Radiat Oncol Biol Phys,2007,67:742-749.