Comparison of setup accuracy between Catalyst HD and skin markers in stereotactic body radiotherapy of lung cancer
Yu Songmao, Zhou Shun, Du Yi, Li Junyu, Sheng Pengfei, Wu Hao, Yue Haizhen
Department of Radiation Oncology,Peking University Cancer Hospital & Institute,Key Laboratory of Carcinogenesis and Translational Research (Ministry of Education/Beijing),Beijing 100142,China
Abstract:Objective To compare the setup accuracy between Catalyst HD and skin markers in stereotactic body radiotherapy (SBRT) of lung cancer. Methods A total of 24 cases treated with SBRT were selected and all patients were fixed with vacuum pad in the supine position. Patients in group A were positioned by Catalyst HD and those in group B were positioned by shin markers. All patients were matched with the CT images after CBCT scan by rigid registration and the setup errors in six directions (x-, y-, z-axis, Rtn, Pitch and Roll) were obtained. Results The mean±SD in group A and B in the six directions were as follows:(0.13±0.12) cm,(0.25± 0.19) cm;(0.26±0.15) cm,(0.13±0.11) cm;(0.23±0.19) cm,(0.35±0.29) cm;(0.43°±0.40°),(0.80°±0.69°);(0.48°±0.47°),(0.79°±0.64°);(0.62°±0.60°) and (0.88°±0.70°), respectively. Except the x-axis data in group B, all the data in the six directions were not normally distributed. The obtained data significantly differed between two groups (all P<0.05). The out-of-tolerance errors (>0.5 cm/2°) also significantly differed between two groups (P<0.05). Conclusions The setup errors of Catalyst HD are less than those of the skin markers (except the y-axis). The setup accuracy of Catalyst HD is superior to that of traditional skin markers, which is worthy of application in clinical practice.
Yu Songmao,Zhou Shun,Du Yi et al. Comparison of setup accuracy between Catalyst HD and skin markers in stereotactic body radiotherapy of lung cancer[J]. Chinese Journal of Radiation Oncology, 2019, 28(10): 772-775.
[1] Nestle U,Guckenberger M. Stereotactic body radiotherapy for malignant nodules in the lung[J]. Zentralbl Chir,2013,138 Suppl 1:S25-31. DOI:10.1055/s-0033-1350866. [2] Mancini-Brandon R,Park-Henry S,Harder-Eileen M,et al. Elderly patients undergoing SBRT for inoperable early-stage NSCLC achieve similar outcomes to younger patients[J]. Lung Cancer,2016,97(1):22-27. DOI:10.1016/j.lungcan.2016.04.011. [3] 董百强,徐裕金,孙晓江,等.200例肺部肿瘤SBRT的经验和疗效[J]. 中华放射肿瘤学杂志,2017,26(6):627-630. DOI:10.3760/cma.j.issn.1004-4221.2017.06.004. Dong BQ,Xu YJ,Sun XJ,et al. Experience and efficacy of SBRT for lung cancer:an analysis of 200 patients[J]. Chin J Radiat Oncol,2017,26(6):627-630. DOI:10.3760/cma.j.issn.1004-4221.2017.06.004. [4] 王昌民,胡伟刚,彭佳元,等. IGRT技术在肺癌SBRT治疗靶区位置误差测定中的应用[J]. 中国临床医学,2016,23(06):841-845. DOI:10.12025/j.issn.1008-6358.2016.20160115. Wang CM,Hu WG,Peng JY,et al. The use of IGRT technique to measure the target position errors in SBRT treatment for lung cancer[J]. Chin J Clin Med,2016,23(06):841-845. DOI:10.12025/j.issn.1008-6358.2016.20160115. [5] 刘晖,张俊,钟亚华,等. 自制体部固定装置在SBRT放疗中的应用分析[J]. 中华放射肿瘤学杂志,2013,22(6):501-503. DOI:10.3760/cma.j.issn.1004-4221.2013.06.021. Liu H,Zhang J,Zhong YH,et al. The analysis of clinical application of.home-made immobilization device in SBRT[J]. Chin J Radiat Oncol,2013,22(6):501-503. DOI:10.3760/cma.j.issn.1004-4221.2013.06.021. [6] 邱健健,吕博,黄莹,等. 基于容积旋转弧形调强放疗技术的肝癌立体定向放疗方案评估与位置误差分析[J]. 中华放射医学与防护杂志,2017,37(2):143-148. DOI:10.3760/cma.j.issn.0254-5098.2017.02.011. Qiu JJ,Lyu B,Huang Y,et al. The feasibility of breath control management guided stereotactic ablation body radiotherapy of liver tumor by volumetric modulated arc therapy[J]. Chin J Radiol Med Prot,2017,37(2):143–148. DOI:10.3760/cma.j.issn.0254-5098.2017.02.011. [7] 颜桂明,方临明,毛佳伟,等. 非小细胞肺癌立体定向放疗的两种体位固定方式比较[J]. 中国现代医生,2014,52(34):148–150+153. Yan GM,Fang LM,Mao JW,et al. Comparison of fixations at two kinds of positions in non-small cell lung cancer stereotactic radiotherapy[J]. Chin Mode Doctor,2014,52(34):148–150+153. [8] 王焱,蔡钢,陆维,等. 肺部肿瘤立体定向放疗技术中基于锥形束CT影像的摆位误差分析[J]. 中国癌症杂志,2017,27(06):501-504. DOI:10.19401/j.cnki.1007-3639.2017.06.017. Wang Y,Cai G,Lu W,et al. Analysis of setup errors in lung stereotactic body radiotherapy with cone-beam CT-based image guidance[J]. Chin Oncol,2017,27(06):501-504. DOI:10.19401/j.cnki.1007-3639.2017.06.017. [9] 张英婷,刘炳忠,陈文芬,等. 聚氨酯发泡胶结合翼板个体化塑形与负压真空袋固定肺癌放疗摆位精度比较[J]. 中华放射肿瘤学杂志,2018,27(3):299-302. DOI:10.3760/cma.j.issn.1004-4221.2018.03.014. Zhang YT,Liu BZ,Chen WF,et al. Comparison of positioning accuracy between personalized polyurethane foam with wing boards and negative pressure vacuum bag in radiotherapy for lung cancer[J]. Chin J Radiat Oncol,2018,27(3):299-302. DOI:10.3760/cma.j.issn.1004-4221.2018.03.014. [10] 高丽娟,黄嘉敏,黄峻,等. Orfit架和真空袋对宫颈癌放疗摆位误差比较[J]. 中华放射肿瘤学杂志,2017,26(9):1080-1083. DOI:10.3760/cma.j.issn.1004-4221.2017.09.020. Gao LJ,Huang JM,Huang J,et al. Setup error of Orfit versus vacuum bag in radiotherapy for cervical cancer[J]. Chin J Radiat Oncol,2017,26(9):1080-1083. DOI:10.3760/cma.j.issn.1004-4221.2017.09.020. [11] 罗焕丽,彭海燕,靳富,等. Catalyst系统在乳腺癌患者放疗摆位应用及影响因素分析[J]. 中华放射肿瘤学杂志,2018,27(2):190-194. DOI:10.3760/cma.j.issn.1004-4221.2018.02.014. Luo HL,Peng HY,Jin F,et al. Catalyst system in patient positioning during.breast cancer radiotherapy:clinical application and influencing factors[J]. Chin J Radiat Oncol,2018,27(2):190-194. DOI:10.3760/cma.j.issn.1004-4221.2018.02.014. [12] Kügele M,Edvardsson A,Berg L,et al. Dosimetric effects of intrafractional isocenter variation during deep inspiration breath-hold for breast cancer patients using surface-guided radiotherapy[J]. J Appl Clin Med Phys,2018,19(1):25-38. DOI:10.1002/acm2.12214. [13] 孙新臣,孙向东,马建新. 肿瘤放射治疗技术学[M]. 南京:东南大学出版社,2015:231-238. Sun XC,Sun XD,Ma JX. Radiation oncology treatment techniques[M]. Nanjing:Southeast university press,2015:231-238. [14] Ruggieri R,Stavrev P,Naccarato S,et al. Optimal dose and fraction number in SBRT of lung tumors:a radiobiological analysis[J]. Phys Med,2017;44:188-195. DOI:10.1016/j.ejmp.2016.12.012. [15] 罗焕丽,靳富,王颖,等. 肿瘤放疗中体外误差与体内误差的关联性[J]. 中国医学物理学杂志,2016,33(1):10-15. DOI:10.3969/j.issn.1005-202X.2016.01.003. Luo HL,Jin F,Wang Y,et al. Correlation between couch errors and target displacements in radiotherapy[J]. Chin J Med Phys,2016,33(01):10-15. DOI:10.3969/j.issn.1005-202X.2016.01.003. [16] Walter F,Freislederer P,Belka C,et al. Evaluation of daily patient positioning for radiotherapy with a commercial 3D surface-imaging system (CatalystTM)[J]. Radiat Oncol,2016,11(1):154. DOI:10.1186/s13014-016-0728-1. [17] Gaisberger C,Steininger P,Mitterlechner B,et al. Three-dimensional surface scanning for accurate patient positioning and monitoring during breast cancer radiotherapy[J]. Strahlenther Onkol,2013,189(10):887-893. DOI:10.1007/s00066-013-0358-6.