Abstract:Objective To analyze geometrical uncertainties of the target and provide the margin enlarging from clinic target volume (CTV) to planning target volume (PTV) with HT. Methods Analysis set-up data of 220 cases include 97 cases of head and neck,45 cases of chest and 78 cases of abdomen and pelvic, calculating the systematic error (Σ) and the random error (σ) in the three-dimension and check whether the set-up data accord with the normal distribution or not, then acquire the values expand in the three directions based on formula 2.0Σ+0.7σand μ±2.58σ. Results The systematic error (Σ) and random error (σ) of head and neck, the chest and abdomen and pelvic were (0.7-1.9 mm,1.1-1.4 mm),(0.8-4.2 mm,1.5-3.2 mm),(1.1-4.1 mm,1.8-4.1 mm),respectively, and the margin that expand in the direction of x, y, z were (5.2,6.5,7.7 mm),(7.5,16.2,10.3 mm),(7.6,17.1,15.7 mm),respectively. Conclusions The curative effect of this task need prove with a large sample during HT, but other should establish data of margin by yourself.
Wang Zhiwei,Duan Jimei,Yue Qi et al. Analysis geometrical uncertainties of 220 cases in helical tomotherapy (HT)[J]. Chinese Journal of Radiation Oncology, 2014, 23(5): 415-417.
[1] International Commission on Radiation Units and Measurements. ICRU Report 50:Prescribing,recording,and reporting photon beam therapy[R]. Bethesda:ICRU Publications,1993. [2] Stroom JC, de Boer HCJ, Huizinga H, et al. Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability[J]. Int J Radiat Oncol Biol Phys,1999,43:905-919. [3] van Herk M, Remeijer P, Rasch C, et al. The probability of correct target dosage:dose-population histograms for deriving treatment margins in radiotherapy[J].Int J Radiat Oncol Biol Phys,2000,47:1121-1135. [4] McKenzie AL, van Herk M, Mijnheer B. The width of margins in radiotherapy treatment plans[J]. Phys Med Biol,2000,45:3331-3342. [5] van Herk M, Remeijer P, Lebesque JV. Inclusion of geometric uncertainties in treatment plan evaluation[J]. Int J Radiat Oncol Biol Phys,2002,52:1407-1442. [6] McKenzie A, van Herk M, Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy[J].Radiother Oncol,2002,62:299-307. [7] van Herk M. Errors and margins in radiotherapy[J].Semin Radiat Oncol,2004,14:52-64. [8] 王鑫,胡超苏,应红梅.放射治疗中的摆位误差[J].肿瘤防治杂志,2004,11:1221-1224. [9] 王鑫,胡超苏,应红梅,等.摆位系统误差对鼻咽癌放疗剂量分布的影响[J].中国癌症杂志,2008,18:620-625. [10] Hurkmans CW, Remeijer P, Lebesque JV, et al. Set-up verification using portal imaging;review of current clinical practice[J].Radiather Oncol,2001,58:105-120.