Abstract: Objective To analyze the setup errors of external-beam and intracavitary radiotherapy for cervical cancer based on the data of cone-beam computed tomography (CBCT), and to provide a basis for clinical practice. Methods Sixty patients with stage ⅡA-ⅢB cervical cancer who were admitted to our hospital and underwent external-beam and intracavitary radiotherapy from March to June, 2015 were enrolled as subjects. Sixty patients with stage ⅡA-ⅢB cervical cancer undergoing conventional external-beam radiotherapy within the same period were also enrolled. The CBCT-based setup errors, containing setup errors in x, y, and z directions and three-dimensional vector deviation, in the initial treatment were obtained from each patient. Comparison of errors between the two treatment approaches was made by independent-samples t test. Results Fitting the data to a linear model revealed that the setup errors in x, y, and z directions increased with the increase in the distance between the position reference point and the center point of the target volume. External-beam radiation combined with intracavitary radiation had significantly reduced setup errors in x, y, and z directions than the conventional external-beam radiation (0.13±0.12 vs. 0.31±0.24, P=0.000;0.23±0.18 vs. 0.47±0.36, P=0.001;0.18±0.11 vs. 0.27±0.18, P=0.001). Conclusions In order to reduce the setup errors, CT scan needs not only a reference marker as close as possible to the center of the tumor, but also a reliable and accurate approach for postural fixation.
Peng Qian,Wang Pei,Wang Xianliang et al. Setup errors of external-beam and intracavitary radiotherapy for cervical cancer:an analysis based on cone-beam computed tomography[J]. Chinese Journal of Radiation Oncology, 2016, 25(10): 1113-1116.
[1] Sheng K,Chow MCJ,Hunter G,et al. Is daily CT image guidance necessary for nasal cavity and nasopharyngeal radiotherapy:an invigation based on helical tomotherapy MVCT Data[J].J Appl Clin Med Phys,2008,9(1):2686.DOI:10.1120/jacmp.v9i1.2686. [2] Hurkmans CW,Remeijer P,Lebesque JV,et al. Set-up verification using portal imaging;review of current clinical practice[J].Radiother Oncol,2001,58(2):105-120.DOI:10.1016/S0167-8140(00)00260-7. [3] Beltran C,Pegram A,Merchant TE.Dosimetric consequences of rotational errors in radiation therapy of pediatric brain tumor patients[J].Radiother Oncol,2012,102(2):206-209.DOI:10.1016/j.radonc.2011.06.013. [4] Perks J,Turnbull H,Liu TX,et al. Vector analysis of prostate patient setup with image-guided radiation therapy via kV cone beam computed tomography[J].Int J Radiat Oncol Biol Phys,2011,79(3):915-919.DOI:10.1016/j.ijrobp.2010.04.008. [5] Nielsen M,Bertelsen A,Wberg J,et al. Cone beam CT evaluation of patient set-up accuracy as a QA tool[J].Acta Oncol,2009,48(2):271-276.DOI:10.1080/02841860802245155. [6] 赵永亮,储开岳,吴建亭,等.胸腹部肿瘤患者放疗体位固定参考等中心与治疗等中心空间距离与后续治疗时摆位误差关系[J].中华放射肿瘤学杂志,2015,24(1):53-54.DOI:10.3760/cma.j.issn.1004-4221.2015.01.015. Zhao Y,Chu KY,Wu JT,et al.The relationship between the position error of the central space and the follow-up treatment of thoracic and abdominal tumor patients after radiotherapy[J].Chin J Radiat Oncol,2015,24(1):53-54.DOI:10.3760/cma.j.issn.1004-4221.2015.01.015. [7] 王多明,秦永辉,古丽娜·库尔班,等.宫颈癌在图像引导调强放疗中摆位误差的分析[J].新疆医科大学学报,2012,35(3):288-292,296.DOI:10.3969/j.issn.1009-5551.2012.03.005. Wang DM,Qin YH,Gulina K,et al. Study in the setup srrors with image guided radiation therapy for uterine cervix cancer[J].J Xinjiang Med Univer,2012,35(3):288-292,296.DOI:10.3969/j.issn.1009-5551.2012.03.005. [8] 徐刚,方临明,吴美书.宫颈癌在图像引导调强放疗中摆位误差的分析[J].中国现代医生,2014,52(21):58-60. Xu G,Fang LM,Wu MS.The analysis of bit errors for patients sith cervicaf cancer by IGRT[J].China Mod Doctor,2014,52(21):58-60. [9] 洪卫,汪莹,陈征,等.用锥形束CT技术测量三维后装与外照射调强融合放疗中施源器位置及外照射摆位误差[J].肿瘤预防与治疗,2012,25(4):224-229.DOI:10.3969/j.issn.1674-0904.2012.04.005. Hong W,Wang Y,Chen Z,et al. Measuring the applicator position and the interfraction setting-up errors by cone beam CT in brachytherapy combined intensity-modulated radiation therapy[J].J Cancer Control Treat,2012,25(4):224-229.DOI:10.3969/j.issn.1674-0904.2012.04.005. [10] Gilbeau L,Octave-Prignot M,Loncol T,et al. Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors[J].Radiother Oncol,2001,58(2):155-162.DOI:10.1016/S0167-8140(00)00280-2.