Abstract:Objective To study the role of KV CBCT on the geometrical accuracy of three-dimensional conformal radiotherapy (3DCRT) and to evaluate the margin of targets and peripheral OAR for thoracic carcinoma. Methods 34 patients with thoracic carcinoma were enrolled. Varian-IX liuac with OBI system was used to acquire CBCT scans before delivery in 3DCRT. The left-right (x), superior-inferior (y), anterior-posterior (z) setup errors of patients can be obtained from the tomography images automatically restructured by the system. Results According to 279 CBCT scans the systemic ±random error on x, y, z directions were (-0.16± 3.25) mm,(-1.36±5.43) mm,(-2.43±2.14) mm and (2.41±2.18) mm,(4.27±3.60) mm,(2.71±1.77) mm respectively if we do not consider the direction of setup errors. The margins of targets were calculated as 2.68 mm, 7.19 mm and 7.57 mm respectively. Conclusions Setup errors are unavoidable in thoracic carcinoma irradiation.We suggest a PTV margin of 2.68 mm, 7.19 mm and 7.57 mm in the left-right, superior-inferior and anterior-posterior directions respectively in our department.
Cao Xiaohui,Liu Ming,Zhai Fushan et al. Analysis of setup errors and margin for thoracic carcinoma radiotherapy with cone-beam CT-based image guidance[J]. Chinese Journal of Radiation Oncology, 2014, 23(1): 53-55.
[1] 杨树松,王凡,孙维浚,等.治疗床面下垂导致的系统摆位误差分析及对策[J].中华放射肿瘤学杂志,2001,10:55-60. [2] Wang L, Jacob R, Chen L, et al. Stereotactic IMRT for prostate cancer:setup accuracy of a new stereotactic body localization system[J]. J Appl Clin Med Phys,2004,5:18-28. [3] van Herk M. Errors and margins in radiotherapy[J]. Semin Radiat Oncol,2004,14:52-64. [4] McKenzie A, Van Herk M, Mijnheer B. Margins for geometric uncertainty around organs at risk in radiotherapy[J]. Radiother Oncol,2002,62:299-307. [5] Mackie TR, Kapatoes J, Ruchala K, et al. Image guidance for precise conformal radiotherapy[J]. Int J Radiat Oncol Biol Phys,2003,56:89-105. [6] 戴建荣,胡逸民.图像放疗的引导方式[J].中华放射肿瘤学杂志,2006,15:132-135. [7] 于金明,袁双虎.图像引导放射治疗研究及其发展[J].中华肿瘤杂志,2006,28:81-83. [8] 吴钦宏,李高峰,王婵,等. 基于锥形束CT体部肿瘤图像引导放疗的摆位误差分析[J].中华放射肿瘤学杂志,2012,21:68-71. [9] 张连胜,张寅,李明辉,等.用锥形束CT技术测量热塑成型膜固定患者的放疗摆位误差[J].中华放射肿瘤学杂志,2008,17:2l9-222. [10] 洪金省,张纬建,陈金梅,等.胸段食管癌三维适形放疗摆位误差研究[J].中华放射肿瘤学杂志,2009,18:182-185. [11] 张寅,张连胜,肖建平,等.用图像引导技术提高胸腹部肿瘤大分割放疗的治疗精度[J].中华放射肿瘤学杂志,2008,17:441-444. [12] 吴君心,谢志原,林育毅,等.应用锥形束CT对盆腔肿瘤放疗计划靶区外放距离的研究[J].中华放射肿瘤学杂志,2010,19:328-330. [13] Hodapp N.The ICRU Report 83:prescribing, recording and reporting photon-beam intensity-modulated radiation therapy (IMRT)[J]. Strahlenther Onkol,2012,188:97-99.