中华放射肿瘤学杂志
Monday, Apr. 14, 2025   Home | Journal | Editorial | Instruction | Subscription | Advertisement | Academic | Index-in | Contact Us | Chinese
Chinese Journal of Radiation Oncology  2021, Vol. 30 Issue (4): 387-391    DOI: 10.3760/cma.j.cn113030-20190709-00266
Physics·Technique·Biology Current Issue| Next Issue| Archive| Adv Search [an error occurred while processing this directive] | [an error occurred while processing this directive]
Study of robust optimization in brachytherapy
Wang Xianliang, Wang Pei, Kang Shengwei, Tang Bin, Yang Feng, Tang Ting, Li Jie
Department of Radiation Oncology, Sichuan Cancer Hospital & Institute, Radiation Oncology Key Laboratory of Sichuan Province, Chengdu 610041, China
Download: PDF (0 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      Supporting Info
Abstract  Objective To evaluate the application value of robost optimization of brachytherapy for cervical cancer. Methods Twenty patients who completed radical treatment were recruited in this study. The dose volume histogram (DVH) parameters were statistically compared between the conventional and robust optimization plans, and the robustness between the conventional and robust optimization plans was evaluated using DVH and DVH bands. The robust optimization method utilized the worst dose distribution to consider the dose in the presence of uncertainties. In each optimization iteration, the dose distributin when the radioactive source shifted along the X, Y, and Z directions (±2 mm), and the dose distribution when the radioactive source was not shifted were calculated. The worst dose distribution for each voxel was the lowest dose in the target and the highest dose outside the target under all circumstances. The iterative objective function was calculated by the worst dose distribution. Results In the scenario of no shifting of radioactive source position, the mean value of robust optimization was significantly lower and that of V150% was significantly higher than those of conventional optimization (both P<0.05). When considering the shifting of radioactive source position, the worst dosimetric parameters of multiple dose distributions were statistically compared. The mean HR-CTV D100% values did not significantly differ between the robust and conventional optimization plans, whereas the mean D90% value (range:0.02-0.03Gy) of robust optimization was significantly higher than that of conventional optimization (P<0.05). Robust optimization increased the D2cm3 of the bladder and small intestine, and the rectum dose was increased with the shifting of the radioactive source position in the robust optimization. The DVH bands did not significantly differ between the conventional and robust optimization plans for all patients. Conclusions Robust optimization based on the worst dose distribution fails to significantly improve the robustness of brachytherapy for cervical cancer. Alternative methods are required to minimize the dosimetric effect of uncertainties in brachytherapy.
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Wang Xianliang
Wang Pei
Kang Shengwei
Tang Bin
Yang Feng
Tang Ting
Li Jie
Key wordsRobust optimization      Uterine cervical neoplasm/intracavitary brachytherapy     
Received: 09 July 2019     
Fund:Key research and development project of chengdu science and technology(2019-YF09-00095-SN)
Corresponding Authors: Li Jie, Email:jie.li@yeah.net   
Cite this article:   
Wang Xianliang,Wang Pei,Kang Shengwei et al. Study of robust optimization in brachytherapy[J]. Chinese Journal of Radiation Oncology, 2021, 30(4): 387-391.
Wang Xianliang,Wang Pei,Kang Shengwei et al. Study of robust optimization in brachytherapy[J]. Chinese Journal of Radiation Oncology, 2021, 30(4): 387-391.
URL:  
http://journal12.magtechjournal.com/Jweb_fszlx/EN/10.3760/cma.j.cn113030-20190709-00266     OR     http://journal12.magtechjournal.com/Jweb_fszlx/EN/Y2021/V30/I4/387
  Copyright © 2010 Editorial By Chinese Journal of Radiation Oncology
Support by Beijing Magtech Co.ltd  support@magtech.com.cn