[an error occurred while processing this directive] | [an error occurred while processing this directive]
Study on patient movements features during radiotherapy
Tan Tingqiang, Li Li, Huang Renbing
Department of Radiation Oncology,Sichuan Cancer Hospital & Institute,Sichuan Cancer Center,School of Medicine,University of Electronic Science and Technology of China,Chengdu 610041,China
AbstractObjective To study the patient movements features during radiotherapy. Methods Randomly selected 120 patients treated in our hospital from February to July on 2016,including 60 thorax treatment and 60 abdomen treatment. The movement data of patient treatment location during radiotherapy treatment was real time monitored by using Sentinel system,movement features of patient's location during radiotherapy was analyzed. Paired t-test difference. Results During radiotherapy,patient's treatment location movement types and proportion were motionless type 14.0%,Moving stable type 64.0%,Jumping type 8.7%,increasing type 13.3%.Patients with thoracic and abdominal radiotherapy,the maximum deviation of IMRT and VMAT treatment were (6.55±2.34) mm and (4.97±1.24) mm (P=0.002),(3.97±1.80) mm and (2.69±1.42) mm (P=0.004).In single treatment,the deviation value of the patient's treatment location increased gradually with the treatment time increasing and the deviant of thoracic is greater than abdominal at the same time after the treatment beginning. Conclusions Patient's treatment location movement during radiotherapy is commonly exist,using the technology of VMAT treatment can effectively reduce the treatment site movement of the patient during the treatment and ensure the accuracy of dose.
Corresponding Authors:
Li Li,Email 646083801@qq.com
Cite this article:
Tan Tingqiang,Li Li,Huang Renbing. Study on patient movements features during radiotherapy[J]. Chinese Journal of Radiation Oncology, 2018, 27(1): 79-82.
Tan Tingqiang,Li Li,Huang Renbing. Study on patient movements features during radiotherapy[J]. Chinese Journal of Radiation Oncology, 2018, 27(1): 79-82.
[1] Jin JY,Ajlouni M,Ryu S,et al. A technique of quantitatively monitoring both respiratory and nonrespiratory motion in patients using external body markers[J].Med Phys,2007,34(7):2875-2881.DOI:10.1118/1.2745237 [2] Ostyn M,Kim S,Yeo WH.A Simulation study of a radiofrequency localization system for tracking patient motion in radiotherapy[J].Sensors,2016,16(4):534.DOI:10.3390/s16040534 [3] Gendrin C,Furtado H,Weber C,et al. Monitoring tumor motion by real time 2D/3D registration during radiotherapy[J].Radiother Oncol,2012,102(2):274-280.DOI:10.1016/j.radonc.2011.07.031 [4] 黎杰,陈川东,康盛伟,等.不同分辨率CT图像Sentinel摆位系统误差研究[J].中华放射肿瘤学杂志,2016,25(8):851-854.DOI:10.3760/cma.j.issn.1004-4221.2016.08.013.Li J,Chen CD,Kang SW,et al. Computed tomography images with different resolutions in Sentinel system:a setup error analysis[J].Chin J Radiat Oncol,2016,25(8):851-854.DOI:10.3760/cma.j.issn.1004-4221.2016.08.013 [5] Barbes B,Azcona JD,Prieto E,et al. Development and clinical evaluation of a simple optical method to detect and measure patient external motion[J].J Appl Clin Med Phys,2015,16(5):306-321.DOI:10.1120/jacmp.v16i5.5524 [6] Pallotta S,Marrazzo L,Ceroti M,et al. A phantom evaluation of SentinelTM,a commercial laser/camera surface imaging system for patient setup verification in radiotherapy[J].Med Phys,2012,39(2):706-712.DOI:10.1118/1.3675973 [7] Pallotta S,Simontacchi G,Marrazzo L,et al. Accuracy of a 3D laser∕camera surface imaging system for setup verification of the pelvic and thoracic regions in radiotherapy treatments[J].Med Phys,2013,40(1):011710.DOI:10.1118/1.4769428 [8] Moser T,Fleischhacker S,Schubert K,et al. Technical performance of a commercial laser surface scanning system for patient setup correction in radiotherapy[J].Phys Med,2011,27(4):224-232.DOI:10.1016/j.ejmp.2010.10.005 [9] Moser T,Habl G,Uhl M,et al. Clinical evaluation of a laser surface scanning system in 120 patients for improving daily setup accuracy in fractionated radiation therapy[J].Int J Radiat Oncol Biol Phys,2013,85(3):846-853.DOI:10.1016/j.ijrobp.2012.05.026 [10] Michalski A,Atyeo J,Cox J,et al. Inter-and intra-fraction motion during radiation therapy to the whole breast in the supine position:a systematic review[J].J Med Imaging Radiat Oncol,2012,56(5):499-509.DOI:10.1111/j.1754-9485.2012.02434.x [11] Klayton T,Price R,Buyyounouski MK,et al. Prostate bed motion during intensity-modulated radiotherapy treatment[J].Int J Radiat Oncol Biol Phys,2012,84(2):130-136.DOI:10.1016/j.ijrobp.2011.11.041 [12] Kupelian P,Willoughby T,Mahadevan A,et al. Multi-institutional clinical experience with the Calypso System in localization and continuous,real-time monitoring of the prostate gland during external radiotherapy[J].Int J Radiat Oncol Biol Phys,2007,67(4):1088-1098.DOI:10.1016/j.ijrobp.2006.10.026 [13] Erridge SC,Seppenwoolde Y,Muller SH,et al. Portal imaging to assess set-up errors,tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer[J].Radiother Oncol,2003,66(1):75-85.DOI:10.1016/s0167-8140(02)00287-6 [14] Norwood HM,Stubbs B.Patient movements during radiotherapy[J].Br J Radiol,1984,57(647):155-158.DOI:10.1259/0007-1285-57-674-155