Abstract Objective To analyze the displacement of titanium clips for tumor bed localization after breast-conserving surgery for breast cancer and its influential factors. Methods A retrospective analysis was performed on the cone-beam computed tomography (CT) images of 14 patients with breast cancer who received radiotherapy after breast-conserving surgery from April to October,2016.The relative position of the chest wall and the errors of the titanium clips in radiotherapy were measured. A Pearson correlation analysis was used to analyze the correlation of the displacement of titanium clips with the relative position of titanium clips,the breast volume,the vertical distance between the titanium clips and the tangential line of the chest wall,and the maximum thickness of the breast. Results The system errors of the chest wall in left-right,superior-inferior,and anterior-posterior directions were 4.42,3.44,and 5.13 mm,respectively,and the random errors were 3.55,3.07,and 4.54 mm,respectively. The titanium clips had a large displacement relative to the chest wall,mainly in the left-right direction. The maximum system error was 4.39 mm and the random error was 2.42 mm. The displacement of titanium clips was not significantly correlated with the breast volume and the maximum thickness of the breast (P>0.05).However,the relative position of titanium clips in superior-inferior direction was significantly correlated with the displacement of the lowest,the most lateral,the most anterior,and the most posterior titanium clips (P<0.05).As to the uppermost clips,there was a significant difference in displacement between the clips close to the chest wall and the clips far from the chest wall (P=0.02). Conclusions Due to large setup error and displacement of titanium clips during radiotherapy,simultaneous integrated boost is not suitable for patients with breast cancer who are immobilized by vacuum cushion and received radiotherapy. The unstable immobilization may be the major influential factor for the displacement of titanium clips.
Fund:Foundation of Science and Technology Department of Sichuan Province (2016FZ0086)
Corresponding Authors:
Li Guangjun,Email:ginick829@sina.com
Cite this article:
Zhong Renming,Xiao Qing,Zhao Jianling et al. CBCT analysis of displacement of titanium clips for tumor bed localization after breast-conserving surgery for breast cancer[J]. Chinese Journal of Radiation Oncology, 2017, 26(7): 768-773.
Zhong Renming,Xiao Qing,Zhao Jianling et al. CBCT analysis of displacement of titanium clips for tumor bed localization after breast-conserving surgery for breast cancer[J]. Chinese Journal of Radiation Oncology, 2017, 26(7): 768-773.
[1] Bartelink H,Horiot JC,Poortmans PM,et al. Impact of a higher radiation dose on local control and survival in breast-conserving therapy of early breast cancer:10-year results of the randomized boost versus no boost EORTC 22881-10882 trial[J].J Clin Oncol,2007,25(22):3259-3265.DOI:10.1200/JCO.2007.11.4991. [2] 丁昀,李建彬,王玮,等.基于四维CT扫描分析金属夹和血清肿确定部分乳腺外照射内大体肿瘤体积及计划靶体积间差异[J].中华肿瘤杂志,2014,36(10):766-770.DOI:10.3760/cma.j.issn.0253-3766.2014.10.010. Ding Y,Li JB,Wang W,et al. Comparison of the volume and localization of internal gross target volume and planning target volume delineated by clips and seroma based on 4D-CT scan for external-beam partial breast irradiation after breast conserving surgery[J].Chin J Oncol,2014,36(10):766-770.DOI:10.3760/cma.j.issn.0253-3766.2014.10.010. [3] Lee HH,Hou MF,Chuang HY,et al. Intensity modulated radiotherapy with simultaneous integrated boost vs.conventional radiotherapy with sequential boost for breast cancer-a preliminary result[J].Breast,2015,24(5):656-660.DOI:10.1016/j.breast.2015.08.002. [4] McDonald MW,Godette KD,Whitaker DJ,et al. Three-year outcomes of breast intensity-modulated radiation therapy with simultaneous integrated boost[J].Int J Radiat Oncol Biol Phys,2010,77(2):523-530.DOI:10.1016/j.ijrobp.2009.05.042. [5] Penninkhof J,Quint S,Baaijens M,et al. Practical use of the extended no action level (eNAL) correction protocol for breast cancer patients with implanted surgical clips[J].Int J Radiat Oncol Biol Phys,2012,82(2):1031-1037.DOI:10.1016/j.ijrobp.2010.12.059. [6] Vaidya JS,Bulsara M,Wenz F,et al. Reduced mortality with partial-breast irradiation for early breast cancer:a meta-analysis of randomized trials[J].Int J Radiat Oncol Biol Phys,2016,96(2):259-265.DOI:10.1016/j.ijrobp.2016.05.008. [7] Park CK,Pritz J,Zhang GG,et al. Validating fiducial markers for image-guided radiation therapy for accelerated partial breast irradiation in early-stage breast cancer[J].Int J Radiat Oncol Biol Phys,2012,82(3):e425-e431.DOI:10.1016/j.ijrobp.2011.07.027. [8] Topolnjak R,de Ruiter P,Remeijer P,et al. Image-guided radiotherapy for breast cancer patients:surgical clips as surrogate for breast excision cavity[J].Int J Radiat Oncol Biol Phys,2011,81(3):e187-e195.DOI:10.1016/j.ijrobp.2010.12.027. [9] Mukesh M,Harris E,Jena R,et al. Relationship between irradiated breast volume and late normal tissue complications:a systematic review[J].Radiother Oncol,2012,104(1):1-10.DOI:10.1016/j.radonc.2012.04.025. [10] Harris EJ,Mukesh MB,Donovan EM,et al. A multicentre study of the evidence for customized margins in photon breast boost radiotherapy[J].Br J Radiol,2016,89(1058):20150603.DOI:10.1259/bjr.20150603. [11] Yue NJ,Goyal S,Zhou JH,et al. Intrafractional target motions and uncertainties of treatment setup reference systems in accelerated partial breast irradiation[J].Int J Radiat Oncol Biol Phys,2011,79(5):1549-1556.DOI:10.1016/j.ijrobp.2010.05.034. [12] Yamashita H,Okuma K,Tada K,et al. Four-dimensional measurement of the displacement of internal fiducial and skin markers during 320-multislice computed tomography scanning of breast cancer[J].Int J Radiat Oncol Biol Phys,2012,84(2):331-335.DOI:10.1016/j.ijrobp.2011.12.030. [13] 韩磊,李建彬,于金明,等.影像引导kV级X线成像测定自由呼吸状态下保乳术后部分乳腺外照射术腔中银夹位移[J].中华肿瘤杂志,2009,31(3):237-238.DOI:10.3760/cma.j.issn.0253-3766.2009.03.022. Han L,Li JB,Yu JM,et al. Silver clip displacement in the external-beam partial breast irradiation cavity on image-guided plain kV radiograph at free breathing in breast cancer patients after conserving surgery[J].Chin J Oncol,2009,31(3):237-238.DOI:10.3760/cma.j.issn.0253-3766.2009.03.022. [14] 李建彬,刘翠翠,孙涛,等.千伏特平片引导ABC辅助部分乳腺外照射术腔中银夹位移研究[J].中华放射肿瘤学杂志,2009,18(2):134-137.DOI:10.3760/cma.j.issn.1004-4221.2009.02.134. Li JB,Liu CC,Sun T,et al. The displacement of silver clips in breast cavity during kV-plain film guided three-dimensional con-formal external-beam partial breast irradiation assisted by active breathing control[J].Chin J Radiat Oncol,2009,18(2):134-137.DOI:10.3760/cma.j.issn.1004-4221.2009.02.134. [15] 王素贞,李建彬,王玮,等.四维CT测定保乳术后部分乳腺外照射术腔中银夹的位移[J].中华肿瘤杂志,2012,34(3):201-204.DOI:10.3760/cma.j.issn.0253-3766.2012.03.009. Wang SZ,Li JB,Wang W,et al. Displacement of the silver clips in surgical cavity based on four-dimensional CT images for patients undertaking external-beam partial breast irradiation after breast-conserving surgery[J].Chin J Oncol,2012,34(3):201-204.DOI:10.3760/cma.j.issn.0253-3766.2012.03.009. [16] 李建彬,张秋实,马志芳,等.适度深吸气呼吸控制下部分乳腺外照射时不同参照物配准对银夹构成几何体位移的影响[J].中华肿瘤杂志,2013,35(12):921-924.DOI:10.3760/cma.j.issn.0253-3766.2013.12.008. Li JB,Zhang QS,Ma ZF,et al. Influence of registration based on different reference markers on the displacement of the geometry consisted of all clips in the cavity for external-beam partial breast irradiation at moderate deep inspiration breath holding[J].Chin J Oncol,2013,35(12):921-924.DOI:10.3760/cma.j.issn.0253-3766.2013.12.008. [17] van Herk M.Errors and margins in radiotherapy[J].Semin Radiat Oncol,2004,14(1):52-64.DOI:10.1053/j.semradonc. 2003.10.003. [18] Harris EJ,Donovan EM,Coles CE,et al. How does imaging frequency and soft tissue motion affect the PTV margin size in partial breast and boost radiotherapy?[J].Radiother Oncol,2012,103(2):166-171.DOI:10.1016/j.radonc.2012.03.015. [19] Penninkhof J,Quint S,de Boer H,et al. Surgical clips for position verification and correction of non-rigid breast tissue in simultaneously integrated boost (SIB) treatments[J].Radiother Oncol,2009,90(1):110-115.DOI:10.1016/j.radonc.2008.10.009. [20] Offerman S,Lamba M,Lavigne R.Effect of breast volume on treatment reproducibility on a tomotherapy unit in the treatment of breast cancer[J].Int J Radiat Oncol Biol Phys,2011,80(2):417-421.DOI:10.1016/j.ijrobp.2010.02.022. [21] Batumalai V,Holloway L,Delaney GP.A review of setup error in supine breast radiotherapy using cone-beam computed tomography[J].Med Dosim,2016,41(3):225-229.DOI:10.1016/j.meddos.2016.05.001. [22] van Mourik A,van Kranen S,den Hollander S,et al. Effects of setup errors and shape changes on breast radiotherapy[J].Int J Radiat Oncol Biol Phys,2011,79(5):1557-1564.DOI:10.1016/j.ijrobp.2010.07.032. [23] Kader HA,Truong PT,Pai R,et al. When is CT-based postoperative seroma most useful to plan partial breast radiotherapy? Evaluation of clinical factors affecting seroma volume and clarity[J].Int J Radiat Oncol Biol Phys,2008,72(4):1064-1069.DOI:10.1016/j.ijrobp.2008.02.049.