Department of Radiation Oncology,Sun Yat-Sen University Cancer Center,Collaborative Innovation Center for Cancer Medicine,State Key Laboratoy of Oncology in Southern China,Guangzhou 510060,China (Peng YL,Deng XW,Han F,Hu J,Wang ML);
Department of Radiation Oncology,Wuzhou Red Cross Hospital,Wuzhou 543000,China (You Y)
Objective To perform a preclinical test of a delineation software based on atlas-based auto-segmentation (ABAS), to evaluate its accuracy in the delineation of organs at risk (OARs) in radiotherapy planning for nasopharyngeal carcinoma (NPC), and to provide a basis for its clinical application. Methods Using OARs manually contoured by physicians on planning-CT images of 22 patients with NPC as the standard, the automatic delineation using two different algorithms (general and head/neck) of the ABAS software were applied to the following tests:(1) to evaluate the restoration of the atlas by the software, automatic delineation was performed on copied images from each patient using the contours of OARs manually delineated on the original images as atlases;(2) to evaluate the accuracy of automatic delineation on images from various patients using a single atlas, the contours manually delineated on images from one patients were used as atlases for automatic delineation of OARs on images from other patients. Dice similarity coefficient (DSC), volume difference (Vdiff), correlation between the DSC and the volume of OARs, and efficiency difference between manual delineation and automatic delineation plus manual modification were used as indices for evaluation. Wilcoxon signed rank test and Spearman correlation analysis were used. Results The head/neck algorithm had superior restoration of the atlas over the general algorithm. The DSC was positively correlated with the volume of OARs and was higher than 0.8 for OARs larger than 1 cc in volume in the restoration test. For automatic delineation with the head/neck algorithm using a single atlas, the mean DSC and Vdiff were 0.81-0.90 and 2.73%-16.02%, respectively, for the brain stem, temporal lobes, parotids, and mandible, while the mean DSC was 0.45-0.49 for the temporomandibular joint and optic chiasm. Compared with manual delineation, automatic delineation plus manual modification saved 68% of the time. Conclusions A preclinical test is able to determine the accuracy and conditions of the ABAS software in specific clinical application. The tested software can help to improve the efficiency of OAR delineation in radiotherapy planning for NPC. However, it is not suitable for delineation of OAR with a relatively small volume.
Corresponding Authors:
Deng Xiaowu,Email:dengxw@mail.sysu.edu.cn
Cite this article:
Peng Yinglin,You Yan,Han Fei et al. Commissioning of an atlas-based auto-segmentation software for application in organ contouring of radiotherapy planning[J]. Chinese Journal of Radiation Oncology, 2016, 25(6): 609-614.
Peng Yinglin,You Yan,Han Fei et al. Commissioning of an atlas-based auto-segmentation software for application in organ contouring of radiotherapy planning[J]. Chinese Journal of Radiation Oncology, 2016, 25(6): 609-614.
[1] Mackie TR,Kapatoes J,Ruchala K,et al. Image guidance for precise conformal radiotherapy[J].Int J Radiat Oncol Biol Phys,2003,56(1):89-105.DOI:10.1016/S0360-3016(03)00090-7. [2] Fang FM,Chien CY,Tsai WL,et al. Quality of life and survival outcome for patients with nasopharyngeal carcinoma receiving three-dimensional conformal radiotherapy vs.intensity-modulated radiotherapy-A longitudinal study[J].Int J Radiat Oncol Biol Phys,2008,72(2):356-364.DOI:10.1016/j.ijrobp.2007.12.054. [3] Chao KSC,Majhail N,Huang CJ,et al. Intensity-modulated radiation therapy reduces late salivary toxicity without compromising tumor control in patients with oropharyngeal carcinoma:a comparison with conventional techniques[J].Radiother Oncol,2001,61(3):275-280.DOI:10.1016/S0167-8140(01)00449-2. [4] Geets X,Daisne JF,Arcangeli S,et al. Inter-observer variability in the delineation of pharyngeal-laryngeal tumor,parotid glands and cervical spinal cord:comparison between CT-scan and MRI[J].Radiother Oncol,2005,77(1):25-31.DOI:10.1016/j.radonc.2005.04.010. [5] Fiorino C,Reni M,Bolognesi A,et al. Intra-and inter-observer variability in contouring prostate and seminal vesicles:implications for conformal treatment planning[J].Radiother Oncol,1998,47(3):285-292.DOI:10.1016/S0167-8140(98)00021-8. [6] Reed VK,Woodward WA,Zhang LF,et al. Automatic segmentation of whole breast using atlas approach and deformable image registration[J].Int J Radiat Oncol Bio Phys,2009,73(5):1493-1500.DOI:10.1016/j.ijrobp.2008.07.001. [7] Chao KSC,Bhide S,Chen H,et al. Reduce in variation and improve efficiency of target volume delineation by a computer-assisted system using a deformable image registration approach[J].Int J Radiat Oncol Biol Phys,2007,68(5):1512-1521.DOI:10.1016/j.ijrobp.2007.04.037. [8] Stapleford LJ,Lawson JD,Perkins C,et al. Evaluation of automatic atlas-based lymph node segmentation for head-and-neck cancer[J].Int J Radiat Oncol Biol Phys,2010,77(3):959-966.DOI:10.1016/j.ijrobp.2009.09.023. [9] Huger S,Graff P,Harter V,et al. Evaluation of the Block Matching deformable registration algorithm in the field of head-and-neck adaptive radiotherapy[J].Phys Med,2014,30(3):301-308.DOI:10.1016/j.ejmp.2013.09.001. [10] 蒋晓芹,段宝风,艾平,等.基于图谱库的自动轮廓勾画软件(ABAS)在鼻咽癌调强放疗中的应用[J].中国医学物理学杂志,2013,30(2):3997-4000,4035.DOI:10.3969/j.issn.1005-202X.2013.02.008. Jiang XQ,Duan BF,Ai P,et al. Clinical evaluation of atlas-based autosegementation (ABAS) in NPC intensity-modulated radiotherapy[J].Chin J Med Phys,2013,30(2):3997-4000,4035.DOI:10.3969/j.issn.1005-202X.2013.02.008. [11] Teguh DN,Levendag PC,Voet PWJ,et al. Clinical validation of atlas-based auto-segmentation of multiple target volumes and normal tissue (swallowing/mastication) structures in the head and neck[J].Int J Radiat Oncol Biol Phys,2011,81(4):950-957.DOI:10.1016/j.ijrobp.2010.07.009. [12] Bharatha A,Hirose M,Hata N,et al. Evaluation of three-dimensional finite element-based deformable registration of pre-and intra-operative prostate imaging[J].Med Phys,2001,28(12):2551-2560.DOI:10.1118/1.1414009. [13] Zijdenbos AP,Dawant BM,Margolin RA,et al. Morphometric analysis of white matter lesions in MR images:method and validation[J].IEEE Trans Med Imaging,1994,13(4):716-724.DOI:10.1109/42.363096. [14] 邹炼,侯氢.图像引导放疗中图像配准算法性质的研究[J].中华放射肿瘤学杂志,2008,17(5):381-384.DOI:10.3321/j.issn:1004-4221.2008.05.013. Zou L,Hou Q.Behaviors study of image registration algorithms in images guided radiation therapy[J].Chin J Radiat Oncol,2008,17(5):381-384.DOI:10.3321/j.issn:1004-4221.2008.05.013. [15] Tsuji SY,Hwang A,Weinberg V,et al. Dosimetric evaluation of automatic segmentation for adaptive IMRT for head-and-neck cancer[J].Int J Radiat Oncol Biol Phys,2010,77(3):707-714.DOI:10.1016/j.ijrobp.2009.06.012. [16] 杜国波,蒋利华,郭飞,等.ABAS软件自动勾画技术在鼻咽癌调强放疗中的应用研究[J].中华放射肿瘤学杂志,2014,23(1):63-64.DOI:10.3760/cma.j.issn.1004-4221.2014.01.018.Du Guofeng,Jiang Lihua,Guo Fei,et al. Application of ABAS software automatic delineation technique in the intensity modulated radiation therapy of nasopharyngeal carcinoma[J].Chin J Radiat Oncol,2014,23(1):63-64.DOI:10.3760/cma.j.issn.1004-4221.2014.01.018. [17] 张秀春,胡彩容,陈传本,等.基于参考图像的ABAS软件自动勾画技术在头颈部肿瘤中的应用研究[J].中华放射肿瘤学杂志,2011,20(6):510-512.DOI:10.3760/cma.j.issn.1004-4221.2011.06.018. Zhang XC,Hu CR,Chen CB,et al. Evaluation of atlas-based autosegmentation with ABAS software for head-and-neck cancer[J].Chin J Radiat Oncol,2011,20(6):510-512.DOI:10.3760/cma.j.issn.1004-4221.2011.06.018. [18] Sims R,Isambert A,Grégoire V,et al. A pre-clinical assessment of an atlas-based automatic segmentation tool for the head and neck[J].Radiother Oncol,2009,93(3):474-478.DOI:10.1016/j.radonc.2009.08.013. [19] Qazi AA,Pekar V,Kim J,et al. Auto-segmentation of normal and target structures in head and neck CT images:a feature-driven model-based approach[J].Med Phys,2011,38(11):6160-6170.DOI:10.1118/1.3654160.