AbstractObjective To evaluate the effect of the thickness and area of the cavity between bolus and skin upon the dose deposition in the shallow tissues. Methods The linear accelerator head model of 6 MV X ray was constructed using Geant4,which simulated the accelerator working condition of 10 cm×10 cm field and recorded the information of emergent particles as phase space file. A water phantom of 30 × 30 × 30 cm3 was designed at the SAD level. A 30 cm × 30 cm × 1 cm water film was constructed adjacent to or with different cavities to the upper surface of the phantom. The phase space file was utilized as particle source to simulate the particle transport process. The axis depth dose distribution and lateral dose profiles in the center area of the field at a depth of 1 mm,5 mm,9 mm,15 mm and 21 mm of the phantom were obtained,respectively. The simulated data obtained from water film with different cavities were compared with those of adjacent to the water phantom. Results When the cavity was ≤ 5 mm,the cavity exerted slight effect. When the thickness was increased,the maximum dose depth (Dmax) was increased,the PDD at Dmax(PDDmax) became less,the depth of influenced lateral dose profiles was increased and the dose in the center area was decreased. Along with the increase of cavity area,the Dmax was initially increased and then decreased,the PDDmax was at first decreased and subsequently increased,the depth of influenced lateral dose profile was initially increased and then decreased,the dose in the center area was first decreased and subsequently increased. The lateral dose profile distant from the cavity or located at a depth ≥15 mm was almost not affected by the cavity. Conclusion The thickness of the cavity between bolus and skin should be less than 5 mm and the cavity area should be small as possible.
Fund:Wuxi Medical Development Discipline (FZXK004)
Corresponding Authors:
Yang Bo,Email:wuxiyangbo@163.com
Cite this article:
Kong Dong,Hui Lin,Wei Xianding et al. Research of effect of cavity between bolus and skin on dose deposition in shallow tissues[J]. Chinese Journal of Radiation Oncology, 2019, 28(1): 27-31.
Kong Dong,Hui Lin,Wei Xianding et al. Research of effect of cavity between bolus and skin on dose deposition in shallow tissues[J]. Chinese Journal of Radiation Oncology, 2019, 28(1): 27-31.
[1] 张敏,赵波,尹金鹏,等.新型3D打印组织补偿物的放疗应用研究[J].中华放射肿瘤学杂志,2017,26(2):210-214.DOI:10.3760/cma.j.issn.1004-4221.2017.02.018. Zhang M,Zhao B,Yin JP,et al. Application of new 3D printing tissue compensator in radiotherapy[J].Chin J Radiat Oncol,2017,26(2):210-214.DOI:10.3760/cma.j.issn.1004-4221.2017.02.018. [2] 李承军,胡健,张爱华,等.6 MV X线时组织等效补偿膜与人体空气间隙对表面剂量的影响[J].医疗卫生装备,2011,32(3):83-84.DOI:10.3969/j.issn.1003-8868.2011.03.033. Li CJ,Hu J,Zhang AH,et al. Effect of tissue equivalent compensation film and human air gap on surface dose in 6 MV x-ray[J].Med Equip,2011,32(3):83-84. DOI:10.3969/j.issn.1003-8868.2011.03.033. [3] 王兴安,谭丽娜,孙晓欢,等.Bolus与皮肤间隙大小对皮肤表面剂量影响的研究[J].中华放射肿瘤学杂志,2015,24(3):299-300.DOI:10.3760/cma.j.issn.1004-4221.2015.03.017. Wang XA,Tan LN,Sun XH,et al. Effects of bolus and skin clearance on skin surface dose[J].Chin J Radiat Oncol,2015,24(3):299-300.DOI:10.3760/cma.j.issn.1004-4221.2015.03.017. [4] Martin JB,Tsang C,Peter Y,et al. Effects on skin dose from unwanted air gaps under bolus in photon beam radiotherapy[J].Radiat Measere,2000,32(2):201-204. DOI:10.4236/jct.2013.47147. [5] Yousaf K,Eduardo VB,Mona U,et al. Clinical and dosimetric implications of air gaps between bolus and skin surface during radiation therapy[J].J Cancer Ther,2013,4(7):1251-1255. DOI:10.4236/jct.2013.47147. [6] Martyna S,Jakub R,Wlodzimierz L.The influence of the bolus-surface distance on the dose distribution in the build-up region[J].Rep Pract Oncol Radiother,2010,15(2):161-164. DOI:10.1016/j.rpor.2010.09.003. [7] 陈华,徐义果,庄志邈,等.放疗计划系统中空腔边缘剂量计算准确性研究[J].中华放射肿瘤学杂志,2017,26(1):69-73.DOI:10.3760/cma.j.issn.1004-4221.2017.01.016. Chen H,Xu YG,Zhuang ZM,et al. Study on the accuracy of cavity edge dose calculation in radiotherapy planning system[J].Chin J Radiat Oncol,2017,26(1):69-73. DOI:10.3760/cma.j.issn.1004-4221.2017.01.016. [8] 赵艳群,黎杰,吴丽萍,等.热塑膜对X射线治疗剂量影响的研究[J].中华放射肿瘤学杂志,2010,19(4):336-339.DOI:10.3760/cma.j.issn.1004-4221.2010.04.018. Zhao YQ,Li J,Wu LP,et al. Study on the effect of thermo-plastic film on the dose of X-ray therapy[J].Chin J Radiat Oncol,2010,19(4):336-339. DOI:10.3760/cma.j.issn.1004-4221.2010.04.018. [9] Geant4 collaboration. Introduction to Geant4[EB/OL][2017-07-05].http://geant4.web.cern.h/geant4/UserDocumentation/UsersGuides/IntroductionToGeant4/html/index.html,2016-12-9. [10] 孔栋,苗利,赵飞,等.西门子加速器射束特点的Geant4模拟研究[J].辐射研究与研究工艺学报,2013,31(5):58-64.DOI:10.11889/j.1000-3436.2014.rrj.31.050801. Kong D,Miao L,Zhao F,et al. Geant4 simulation of beam characteristics of Siemens accelerator[J].J Radiat Res Radiat Proc,2013,31(5):58-64. DOI:10.11889/j.1000-3436.2014.rrj.31.050801. [11] 谢志原,吴君心.图像引导放射治疗的应用和展望[J].肿瘤学杂志,2013,19(4):241—244. Xia ZY,Wu JX.Application and prospect of image-guided radiotherapy[J].J Oncol,2013,19(4):241-244. [12] 李士骏.电离辐射剂量学基础[M].苏州:苏州大学出版社,2008. Li SJ.Dosimetry basis for ionizing radiation[M].Suzhou:Suzhou university press,2008. [13] 王峻峰,李定宇,黄章玲,等.Merkel细胞癌电子线放疗中3D打印补偿物的模拟应用[J].中华放射肿瘤学杂志,2016,25(9):999-1002.DOI:10.3760/cma.j.issn.1004-4221.2016.09.022. Wang Junfeng,Li Dingyu,Huang Zhangling,et al. Simulation and application of 3D printed compensator in electron radiation therapy for Merkel cell carcinoma[J].Chin J Radiat Oncol,2016,25(9):999-1002. DOI:10.3760/cma.j.issn.1004-4221.2016.09.022.