A preliminary study of test and clinical application of a physical model based on the three-dimensional dose verification system using electronic portal imaging device
Department of Radiation Oncology,Affiliated Union Hospital,Fujian Medical University,Fuzhou 350001,China (Huang MY,Chen MQ,Chen YG,Li XB,Xu BH); Department of Radiation Ontology,SUN Yat-sen University Cancer Center,Guangzhou 510060,China (Chen LX)
Abstract Objective To establish a physical model and optimize its physical parameters using the electronic portable imaging device (EPID) three-dimensional dose verification system, and to prepare it for clinical application. Methods EPID was used to acquire images of 3, 5, 10, 15, 20, and 25 cm square fields for construction of a physical model. The parameters of the physical model were optimized based on the percentage depth dose, total scatter factor, and off-axis ratio at a depth of 10 cm in a homogeneous water phantom. A thimble ionization chamber and radiochromic films were used to measure the point and planar doses for single fields, combined fields, and IMRT plans in a homogenous phantom and a human phantom. The results were compared with those in the three-dimensional reconstruction. In the human phantom and 10 intensity-modulated radiotherapy (IMRT) plans for tumors in different sites, the passing rates under the criteria of 5%/3 mm and 3%/3 mm were compared between three-dimensional reconstruction and treatment planning system (TPS) calculation. The dose and volume analyses were performed on target volume and organs at risk (OARs) in patients. Results For the single fields, combined fields, and IMRT plans, the mean deviations of point dose were less than 0.5% between three-dimensional reconstruction and ionization chamber measurement, and less than 2.0% between three-dimensional reconstruction and TPS calculation. In the homogenous phantom, the human phantom, and patients, the mean passing rates of both two-and three-dimensional doses were higher than 95% under the criteria of 5%/3 mm and 3%/3 mm. In patients, however, OARs with small volume had relatively large dose deviations. Conclusions A series of pre-clinical tests show that the three-dimensional dose verification system is an effective approach for clinical dose verification and holds promise for clinical application.
Huang Miaoyun,Chen Mingqiu,Li xiaobo et al. A preliminary study of test and clinical application of a physical model based on the three-dimensional dose verification system using electronic portal imaging device[J]. Chinese Journal of Radiation Oncology, 2016, 25(12): 1335-1340.
Huang Miaoyun,Chen Mingqiu,Li xiaobo et al. A preliminary study of test and clinical application of a physical model based on the three-dimensional dose verification system using electronic portal imaging device[J]. Chinese Journal of Radiation Oncology, 2016, 25(12): 1335-1340.
[1] Kapatoes JM,Olivera GH,Balog JP,et al. On the accuracy and effectiveness of dose reconstruction for tomotherapy[J].Phys Med Biol,2001,46(4):943-966. [2] Steciw S,Warkentin B,Rathee S,et al. Three-dimensional IMRT verification with a flat-panel EPID[J].Med Phys,2005,32(2):600-612. [3] van Elmpt,Wouter JC,Nijsten,et al. A Monte Carlo based three-dimensional dose reconstruction method derived from portal dose images[J].Med Phys,2006,33(7):2426-2434. [4] Van Uytven E, Van Beek T, McCowan PM,et al. Validation of a method for in vivo 3D dose reconstruction for IMRT and VMAT treatment using on-treatment EPID image and a model-based forward-calculation algorithm[J].Radiother Oncol,2015,42(12):6945-6954.10.1118/1.4935199. [5] Chytyk-Praznik K,Vanuytven E,Vanbeek TA,et al. Model-based prediction of portal dose images during patient treatment[J].Med Phys,2013,40(3):031713. 10.1118/1.4792203. [6] Zijtveld MV,Dirkx M,Boer HD,Heijmen B.3D dose reconstruction for clinical evaluation of IMRT pretreatment verification with an EPID[J].Radiother Oncol,2007,76(2):201-207.10.1016/j.radonc.2006.12.010 [7] 黄妙云.基于EPID建立调强三维剂量验证物理模型及临床应用的研究[D].福建:清华大学医学院,2016. Huang MY.Study on the establishment of the physical model and clinical application of three dimensional dose verification based on EPID[D].Fujian:Medical College of Tsinghua University,2016. [8] 朱金汉,陈立新,靳光华,等.基于电子射野影像装置的容积调强弧形治疗二维剂量验证研究[J].中华放射肿瘤学杂志,2012,21(6):550-553.10.3760/cma.j.issn.1004-4221.2012.06.020. Zhu JH,Chen LX,Jin GH,et al. The study of two-dimensional dosimetric verifications of volumetric intensity-modulated arc therapy based on electronic portal imaging devices[J].Chin J Radiat Oncol,2012,21(6):550-553.10.3760/cma.j.issn.1004-4221.2012.06.020. [9] Zhu J,Chen L,Chen A,et al. Fast 3D dosimetric verifications based on an electronic portal imaging device using a GPU calculation engine[J].Radiat Oncol,2015,10:85.10.1186/s13014-015-0387-7. [10] 曹午飞,黄晓延,孙文钊,等.剂量分布验证中分辨率对γ通过率的影响[J].中华放射肿瘤学杂志,2012,21(2):172-175.10.3760/cma.j.issn.1004-4221.2012.06.023. Cao WF,Huanf XY,Sun WZH,et al. The impact of resolution to γ rate in the verification of dose distribution[J].Chin J Radiat Oncol,2012,21(6):550-553.10.3760/cma.j.issn.1004-4221.2012.06.023. [11] McCurdy BMC,Luchka K,Pistorius S.Dosimetric investigation and portal dose image prediction using an amorphous silicon electronic portal imaging device[J].Med Phys,2001,28(6):911-924. [12] Partridge M,Groh B,Spies L,et al. A study of the spectral response of portal imaging detectors[J].IEEE Nuc Sci Symp Conf Rec,2000,3:19-27. [13] Rana S,Rogers K.Dosimetric evaluation of Acuros XB dose calculation algorithm with measurements in predicting doses beyond different air gap thickness for smaller and larger field sizes[J].Med Phys,2013,38(1):9-14.10.4103/0971-6203.106600. [14] 陈阿龙,陈立新,陈利,等.基于三维影像解剖结构的调强剂量验证的初步研究[J].中华放射肿瘤杂志,2014,23(4):352-356.10.3760/cma.j.issn.1004-4221.2014.04.019. Chen AL,Chen LX,Chen L,et al. A primary research of intensity-modulated dose verification based on anatomic structure of three-dimensional images[J].Chin J Radiat Oncol,2014,23(4):352-356.10.3760/cma.j.issn.1004-4221.2014.04.019. [15] Wendling M,Louwe RJ,McDermott LN,et al. Accurate two-dimensional IMRT verification using a back-projection EPID dosimetry method[J].Med Phys,2006,33(2):259-273. [16] 林海磊,黄劭敏,邓小武,等.基于解剖在线测量的调强放疗三维剂量验证系统测试与应用[J].中华放射肿瘤杂志,2012,21(3):271-275.10.3760/cma.j.issn.1004-4221.2012.03.023. Lin HL,Huang SHM,Deng XW,et al. A clinical test and application research of IMRT dose verification system based on patient′s anatomical structure and on-line dosimetry[J].Chin J Radiat Oncol,2012,21(3):271-275.10.3760/cma.j.issn.1004-4221.2012.03.023.