Abstract Objective To investigate the correlation between setup error and couch position error in radiotherapy. Methods A total of 25 patients with thoracic and abdominal tumors who recently finished image-guided radiotherapy were randomly selected. The data on couch position during treatment were obtained through the record validation system, and then the couch position error was calculated. The Pearson correlation analysis was used to investigate the correlation between setup error and couch position error during treatment. Results In the ≥5 setup errors among the 25 patients, the correlation coefficient between random setup error and random couch position error was 0.83(P=0.00), and the correlation coefficient between systematic setup error and systematic couch position error was 0.36(P=0.11). Conclusions In radiotherapy, the random setup error is highly correlated with the random couch position error, while a moderate or low correlation exists between the systematic setup error and the systematic couch position error.
Corresponding Authors:
Dai Jianrong,Email:jianrong_dai@163.com
Cite this article:
Fu Guishan,Cheng Bin,Qin Shirui et al. Analyzing of correlation between the setup error and the couch position in radiotherapy[J]. Chinese Journal of Radiation Oncology, 2016, 25(3): 266-269.
Fu Guishan,Cheng Bin,Qin Shirui et al. Analyzing of correlation between the setup error and the couch position in radiotherapy[J]. Chinese Journal of Radiation Oncology, 2016, 25(3): 266-269.
[1] 游爱敏,王秀玲,林院生.不同部位肿瘤放疗体位重复性分析[J].实用癌症杂志,2010,25(4):391-393.DOI:10.3969/j.issn.1001-5930.2010.04.021. You AM,Wang XL,Lin YS.Analyses of the position reproducibilities of different region tumors[J].Pract J Cancer,2010,25(4):391-393.DOI:10.3969/j.issn.1001-5930.2010.04.021. [2] 李兴德,翟福山,张明云,等.胸部肿瘤患者体重指数对摆位误差的影响[J].中华放射肿瘤学杂志,2015,24(1):40-41.DOI:10.3760/cma.j.issn.1004-4221.2015.01.011. Li XD,Zhai FSH,Zhang MY,et al. Body mass index in patients with chest tumor effects on set-up errors[J].Chin J Radiat Oncol,2015,24(1):40-41.DOI:10.3760/cma.j.issn.1004-4221.2015.01.011. [3] 梁军,张涛,张寅,等.肺癌锥形束CT图像不同配准方式的误差分析[J].中华放射肿瘤学杂志,2011,20(2):106-108.DOI:10.3760/cma.j.issn.1004-4221.2011.02.007. Liang J,Zhang T,Zhang Y,et al. Cone-beam CT imagine registration of lung cancer[J].Chin J Radiat Oncol,2011,20(2):106-108.DOI:10.3760/cma.j.issn.1004-4221.2011.02.007. [4] 陈国付,张飞燕,方临明,等.热塑膜体位固定技术在放疗中的应用[J].浙江临床医学,2011,13(11):1286-1287.DOI:10.3969/j.issn.1008-7664.2011.11.042. Chen GF,Zhang FY,Fang LM,et al. Thermoplastic membrane immobilization technology and its application in radiation therapy[J].Zhejiang Clinl Med,2011,13(11):1286-1287.DOI:10.3969/j.issn.1008-7664.2011.11.042. [5] Hadley SW,Lam KL,Balter JM.Analysis of couch position tolerance limits to detect mistakes in patient setup[J].J Appl Clin Med Phys,2009,10(4):2864.DOI:10.1120/jacmp.v10i4.2864. [6] de Boer HCJ,Heijmen BJ.eNAL:an extension of the NAL setup correction protocol for effective use of weekly follow-up measurements[J].Int J Radiat Oncol Biol Phys,2007,67(5):1586-1595.DOI:10.1016/j.ijrobp.2006.11.050. [7] Wu QW,Lockman D,Wong J,et al. Effect of the first day correction on systematic setup error reduction[J].Med Phys,2007,34(5):1789-1796.DOI:10.1118/1.2727299. [8] de Kruijf WJM,Martens RJW.Reducing patient posture variability using the predicted couch position[J].Med Dosim,2015,40(3):218-221.DOI:10.1016/j.meddos.2014.12.002. [9] Becker SJ,Culberson W,Flynn R.Collision indicator charts for gantry-couch position combinations for Siemens ONCOR and Elekta Infinity linacs[J].J Appl Clin Med Phys,2013,14(5):278-283.DOI:10.1120/jacmp.v14i5.4355. [10] Patton GA,Gaffney DK,Moeller JH.Facilitation of radiotherapeutic error by computerized record and verify systems[J].Int J Radiat Oncol Biol Phys,2003,56(1):50-57.DOI:10.1016/S0360-3016(02)04418-8.