Introduction of relevant criteria for quality assurance and quality control of tumor radiotherapy at home and abroad
Fu Qingguo, Dai Jianrong, Zhu Xiaodong, Chen Long, Liu Zhijie
Department of Radiation Oncology,Cancer Hospital Affiliated to Guangxi Medical University,Guangxi Quality Control Center for Radiotherapy,Nanning 530021,China (Fu QG,Zhu XD,Chen L) Department of Radiation Oncology,National Cancer Center/Cancer Hospital,Chinese Academy of Medical Sciences,Peking Union Medical College,Beijing 100021,China (Dai JR)
Abstract:Multiple institutions at home and abroad have established and issued the standards, guidelines, criteria or reports of the quality assurance (QA) and quality control (QC) of radiotherapy. At present, no institutions in China have implemented systematic classification of QA-and QC-related criteria of radiotherapy. Complete standard system of QA and QC of radiotherapy should consist of clinical and physical technologies. Physical technology includes equipment, technological flow and radiation protection. The QA and QC of physical technology play a pivotal role in tumor radiotherapy. This paper introduces relevant criteria of QA and QC of radiotherapy at home and abroad.
Fu Qingguo,Dai Jianrong,Zhu Xiaodong et al. Introduction of relevant criteria for quality assurance and quality control of tumor radiotherapy at home and abroad[J]. Chinese Journal of Radiation Oncology, 2018, 27(2): 218-221.
[1] 胡逸民,张红志,戴建荣,等.肿瘤放射物理学[M].北京:原子能出版社,1999:612-637.Hu YM, Zhang HZH, Dai JR. Radiation Oncology Physics[M].Peking:Atomic Energy Press,1999:612-637. [2] 马攀,戴建荣.放疗质量管理新方法[J].中华放射肿瘤学杂志.2015,24(6):732-735.DOI;10.3760/cma.issn.1004.2015.06.032Ma P, Dai JR. New method of radiotherapy quality management[J].Chin J Radiat Oncol.2015,24(6):732-735. DOI;10.3760/cma.issn.1004.2015.06.032 [3] AAPM. Task Group 142 Report. quality assurance of medical accelerators[R].Medical Physics,2009,36(9).DOI:10.1118/1.3190392 [4] AAPM. Report No.47(Task Group 45).AAPM code of practice for radiotherapy accelerators[R]. Medical Physics,1994,21(7). [5] 姚杏红,陈立新等.不同指形电离室测量高能光子束吸收剂量的比较[J].中华放射医学与防护杂志,2012.32(4):412-415.DOI:10.3760/cma.j.issn.0254-5098.2012.04.023.Yao XL, Chen LX, et al. Comparative determiniation of absorbed doses for high-energy photon beam with different cylindrical chambers. Chin J Radiol Med Prot,2012.32(4):412-415.DOI:10.3760/cma.j.issn.0254-5098.2012.04.023 [6] AAPM. Task Group 40 Report. Comprehensive QA for radiation oncology[R]. Medical Physics,1994,21(4). [7] AAPM. Task Group 66 Report. Quality assurance for computed-tomography simulators and the computed-tomography-simulation process[R]. Medical Physics,2003,30(410).DOI:10.1118/1.609271 [8] IAEA. Human Health series No.19.Quality assurance programme for computed tomography:diagnostic and therapy applications[R].International Atomic Energy Agency,VIENNA,2012 [9] IAEA. Human health series no.7.record and verify systems for radiation treatment of cancer:acceptance esting,commissioning and quality control[R]. tInternational Atomic Energy Agency,VIENNA,2013 [10] AAPM. Task group 100 report.application of risk analysis methods to radiation therapy quality management[R]. Medical Physics,2016,43(7).DOI:10.1118/1.4947547 [11] IAEA. TECDOC No.1685,application of the risk matrix method to radiotherapy[R]. International Atomic Energy Agency,VIENNA,2016 [12] AAPM. Report No.82.guidance document on delivery,treatment planning and clinical implementation of IMRT[R]. Medical Physics,2003,30(8).DOI:10.1118/1.1591194 [13] AAPM. Task group 119 report. IMRT commissioning:Multiple institution planning and dosimetry comparisons[R]. Medical Physics,2009,36(11).DOI:10.1118/1.3238104 [14] AAPM. Task group 120 report.dosimetry tools and techniques for IMRT[R]. Medical Physics,2011,38(3).DOI:10.1118/1.3514120