Laboratory of Image Science and Technology,Southeast University,Centre de Recherché en Information Biomédicale Sino-franais,Nanjing 210096,China (Zhu J,Li BSH,Shu HZH,Luo LM);Department of Radiation Oncology Physics,Shandong Cancer Hospital and Institute,Ji’nan 250117,China (Zhu J, Bai T,Hou ZH,Lu J,Yin Y);Depatment of Radoation Oncology,Tumor Hospital of Xinjiang Medical University,Urumqi 830000,China (Wang RZH)
Abstract:Objective To investigate the dose evaluation method for adaptive radiotherapy plans based on script functions, so that the function of radiotherapy plan transfer in the Dynamic Planning module can be completed by all versions of Pinnacle treatment planning system (TPS). Methods The first step was to write and embed the scripts, and then the isocenter of irradiation was set up in the late-course image space. The scripts were executed to export and import the radiation field and set up the weight, so as to realize the transfer of radiotherapy plan between different image spaces. This method and the Dynamic Planning module of Pinnacle TPS were used to evaluate the adaptive radiotherapy plan of one patient with nasopharyngeal carcinoma, and these two methods were compared in terms of plan parameters and dosimetry. Results Compared with the Dynamic Planning module, this method maintained the consistency in the fore-and late-course plan parameters of the radiotherapy plan. The two methods had different positions of the isocenter, which caused the difference in dose distribution;however, if the two methods transferredthe adaptive radiotherapy plan at the same isocenter, the dose distribution was exactly the same. Conclusions This method for the evaluation of adaptive radiotherapy plans is accurate, simple, convenient, and applicable to all versions of Pinnacle TPS, and it does not take up additional image storage space. This method increases the flexibility and precision of radiotherapy dose evaluation and provides a technical support for clinical practice and research.
Zhu Jian,Bai Tong,Hou Zhen et al. Dose evaluation method for adaptive radiotherapy plans based on script functions[J]. Chinese Journal of Radiation Oncology, 2016, 25(9): 984-987.
[1] Yan D.Adaptive radiotherapy:merging principle into clinical practice[J].Semin Radiat Oncol,2010,20(2):79-83.DOI:10.1016/j.semradonc.2009.11.001. [2] Zarepisheh M,Long T,Li N,et al. A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning[J].Med Phys,2014,41(6):061711.DOI:10.1118/1.4875700. [3] Philips. Philips pinnacle3 dynamic planning specifications[EB/OL].[2012-01-05].http://incenter.medical.philips.com/doclib/enc/fetch/2000/4504/577242/591403/591458/591459/Pinnacle%25ufffd_Dynamic_Planning_Specifications.pdf%3fnodeid%3 d10256574%26vernum%3 d1. [4] Yan D,Vicini F,Wong J,et al. Adaptive radiation therapy[J].Phys Med Biol,1997,42(1):123-132.DOI:10.1088/0031-9155/42/1/008. [5] Zarepisheh M,Long T,Li N,et al. A DVH-guided IMRT optimization algorithm for automatic treatment planning and adaptive radiotherapy replanning[J].Med Phys,2014,41(6):061711.DOI:10.1118/1.4875700. [6] Rhee D J.The need for adaptive intensity modulated radiotherapy replanning in head-and neck patients with anatomical changes during treatment[D].Durham:Duke University,2013. [7] Schwartz D L,Garden A S,Thomas J,et al. Adaptive radiotherapy for head-and-neck cancer:initial clinical outcomes from a prospective trial[J].Int J Radiat Oncol Biol Phys,2012,83(3):986-993.DOI:10.1016/j.ijrobp.2011.08.017. [8] Lu J,Ma YD,Chen JH,et al. Assessment of anatomical and dosimetric changes by a deformable registration method during the course of intensity-modulated radiotherapy for nasopharyngeal carcinoma[J].J Radiat Res,2014,55(1):97-104.DOI:10.1093/jrr/rrt076. [9] Pinnacle3 planning reference guide[M].9201-5136A-ENG Rev A.Fitchburg USA:Philips Medical System,2008. [10] Geoghegan S.Scripting on the Pinnacle3 treatment planning system[M].Perth,AUS:Royal Perth Hospital,2007. [11] 陈维军,狄小云,王彬冰,等.Pinnacle计划系统脚本在调强放疗计划中的应用研究[J].中国医学物理学杂志,2010,27(3):1858-1861.DOI:10.3969/j.issn.1005-202X.2010.03.010. Chen WJ,Di XY,Wang BB,et al. Application of scripting in Pinnacle tps for IMRT planning[J].Chin J Med Phys,2010,27(3):1858-1861.DOI:10.3969/j.issn.1005-202X.2010.03.010. [12] 张建英.Pinnacle计划系统脚本应用方法的探讨[J].中国医学物理学杂志,2009,26(5):1391-1394,1448. Zhang JY.A discussion to the advanced application of scripting in pinnacle TPS system[J].Chin J Med Phys,2009,26(5):1391-1394,1448. [13] 朱健,李宝生,舒华忠,等. 一种从Pinnacle放疗计划系统中导出并重建剂量体积直方图的方法. 中华放射肿瘤学杂志. 2014,23(1):34-35. Zhu J, Li BS, Shu HZ, et al. A method of dose-volume-histogram exporting and reconstruction from Pinnacle treatment planning system. Clin J Radiat Oncol, 2014, 23(1):34-35.