Abstract: Objective To compare the effects of positioning robustness on dose distribution between intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT) for head and neck tumor, and to evaluate their needs for image-based guidance. Methods Thirty patients with nasopharyngeal carcinoma undergoing IMRT were enrolled as subjects. The VMAT plans were designed according to the clinical dosimetric requirements and the dose calculation was made by the AAA method. For the two plans in each patient, the isocenters were shifted by ±1.0, ±3.0, and ±5.0 mm along the original x, y, and z axes to simulate the impacts of positioning errors in left-right (LR), superior-inferior (SI), and anterior-posterior (AP) directions, respectively, on dose distribution. The dose-volume histogram parameters were analyzed in 60 references and 1080 re-calculated plans. Comparison was made by paired t-test. Results When the error was 1 mm, the average deviations of gross tumor volume (GTV) D98, clinical target volume (CTV) D95 and heterogeneity index, and planning gross tumor volume (PGTV) V95 were<0.5%. When the error was 3 mm, the average dose deviations of GTV and CTV were<1.0% and significantly larger in VMAT than in IMRT;the average dose deviation of PGTV was large (GTV D98,P=0.00;CTV D95,P=0.00);the average deviations of PGTVnx V95 and PGTVnd V95 were significantly smaller in IMRT than in VMAT (1.64% vs. 1.95%, P=0.01;1.73% vs. 2.63%, P=0.00). The deviations of parameters became larger with the increasing positioning error and were significantly larger in VMAT than in IMRT (GTV D98,P=0.00;CTV D95,P=0.00;CTV HI;P=0.00;PGTV V95;P=0.01). Compared with the target volume, Dmax to the spinal cord and brain stem had larger deviations. However, there were no significant differences in Dmax to the spinal cord and brain stem between IMRT and VMAT. Conclusions The IMRT and VMAT plans are both robust when the positioning error is small (<3 mm). Compared with IMRT, VAMT is more sensitive to the positioning error, mainly in the target volume. The difference between the two plans becomes larger with the increasing positioning error. An increase in the frequency of image-based guidance is recommended for patients undergoing VMAT.
Zhang Biao,Jia Pengfei,Tang Lemin. Effects of positioning robusntness on dosimetry for intensity-modulated radiation therapy and volumetric modulated arc therapy[J]. Chinese Journal of Radiation Oncology, 2017, 25(7): 676-680.
[1]Ong CL,Verbakel WFAR,Cuijpers JP,et al. Dosimetric impact of interplay effect on rapidarc lung stereotactic treatment delivery[J].Int J Radiat Oncol Biol Phys,2011,79(1):305-311.DOI:10.1016/j.ijrobp.2010.02.059 [2]Ong CL,Dahele M,Cuijpers JP,et al. Dosimetric impact of intrafraction motion during rapidarc stereotactic vertebral radiation therapy using flattened and flattening filter-free beams[J].Int J Radiat Oncol Biol Phys,2013,86(3):420-425.DOI:10.1016/j.ijrobp.2012.12.028 [3]Li RJ,Han B,Meng BW,et al. Clinical implementation of intrafraction cone beam computed tomography imaging during lung tumor stereotactic ablative radiation therapy[J].Int J Radiat Oncol Biol Phys,2013,87(5):917-923.DOI:10.1016/j.ijrobp.2013.08.015 [4]International Commission on Radiation Units and Measurements (ICRU):ICRU Report 78:Prescribing,Recording,and Reporting Proton-Beam Therapy[R].Bethesda MD:ICRU,2007 [5]Cantone MC,Ciocca M,Dionisi F,et al. Application of failure mode and effects analysis to treatment planning in scanned proton beam radiotherapy[J].Radiat Oncol,2013,8(1):127.DOI:10.1186/1748-717X-8-127 [6]Lomax AJ.Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2:the potential effects of inter-fraction and inter-field motions[J].Phys Med Biol,2008,53(4):1043-1056.DOI:10.1088/0031-9155/53/4/015 [7]Jkel O,Krmer M,Karger CP,et al. Treatment planning for heavy ion radiotherapy:clinical implementation and application[J].Phys Med Biol,2001,46(4):1101-1116.DOI:10.1088/0031-9155/46/4/314 [8]孙晓欢,谭丽娜,马奎,等.摆位误差对VMAT计划剂量学验证的影响[J].中华放射肿瘤学杂志,2014,23(6):513-515.DOI:10.3760/cma.j.issn.1004-4221.2014.06.014 Sun XH,Tan LN,Ma K,et al. Effect of the setup error on the dosimetric verification for the volumetric modulated arc therapy[J].Chin J Radiat Oncol,2014,23(6):513-515.DOI:10.3760/cma.j.issn.1004-4221.2014.06.014 [9]Yin WJ,Sun Y,Chi F,et al. Evaluation of inter-fraction and intra-fraction errors during volumetric modulated arc therapy in nasopharyngeal carcinoma patients[J].Radiat Oncol,2013,8(1):78.DOI:10.1186/1748-717X-8-78 [11]Mongioj V,Orlandi E,Palazzi M,et al. Set-up errors analyses in IMRT treatments for nasopharyngeal carcinoma to evaluate time trends,PTV and PRV margins[J].Acta Oncol,2011,50(1):61-71.DOI:10.3109/0284186X.2010.509108 [11]Lai YL,Yang SN,Liang JA,et al. Impact of body-mass factors on setup displacement in patients with head and neck cancer treated with radiotherapy using daily on-line image guidance[J].Radiat Oncol,2014,9(1):19.DOI:10.1186/1748-717X-9-19.