Abstract:Objective To evaluate the efficacy of tailor-made mouth bite block for auxiliarypositioning in reducing setup errors during radiotherapy for nasopharyngeal carcinoma (NPC). MethodsThe NPC patient to be treated with radiotherapy was immobilized with a thermoplastic mask covering the head, neck, and shoulder, with the addition of a tailor-made mouth bite block to help positioning. The patient′s position was verified by the On-Board Imager system for the first three times of radiotherapy and then once every week. Results The mean setup errors in left-right, superior-inferior, and anterior-posterior directions were -0.26, 0.36, and 0.35 mm, respectively, and the standard deviations were 0.97, 1.16, and 1.11 mm, respectively;the frequencies of setup error ≤2 mm in the three directions were 99.7%, 98.0%, and 100%, respectively. Conclusion Tailor-made mouth bite block can help improve the positioning accuracy during radiotherapy for NPC.
Zhang Tao,Xiao Guangli,Wu Zhaoping et al. Efficacy of tailor-made mouth bite block in reducing setup errors during radiotherapy for nasopharyngeal carcinoma[J]. Chinese Journal of Radiation Oncology, 2015, 24(2): 173-175.
[1]王鑫,胡超苏,应红梅,等.摆位系统误差对鼻咽癌放疗剂量分布的影响[J].中国癌症杂志,2008,18(8):620-625.DOI:10.3969/j.issn.1007-3639.2008.08.013. [2]International commission on radiation units and measurements. ICRU 24.Determination of absorbed dose in a patient irradiated by beam of X or gamma rays in radiotherapy procedures. Washington DC:international commission on radiation units and measurements[S]. Bethesda:ICRU,1976. [3]潘建基,潘才住,陈传本,等.摆位系统误差对鼻咽癌调强放疗剂量的影响[J].中华放射肿瘤学杂志,2007,16(5):394-396. DOI:10.3760/j.issn:1004-4221.2007.05.018. [4]Stroom JC,de Boer JC,Huizenga H,et a1.Inclusion of geometrical uncertainties in radiotherapy treatment planning by means of coverage probability[J].Int J Radiat 0ncol Biol Phys,1999,43(4):905-919. DOI:10.1016/S0360-3016(98)00468-4. [5]Van Herk M, Remeijer P,Rasch C, el a1.The probability of correct target dosage:dose-population histograms for deriving treatment margins in radiotherapy[J].Int J RadiatOneolBiol Phys,2000,47(4):1121-1135.DOI:10.1016/S0360-3016(00)00518-6. [6]Van Herk M.Errors and margins in radiotherapy.[J].Semin Rasiat Oncol,2004,14(1):52-64. DOI:10.1053/j.semradonc.2003.10.003. [7]李明辉,张寅,戴建荣,等.千伏级X线透视成像与锥形束CT确定头颈部摆位误差的比较[J].中华放射肿瘤学杂志,2012,21(4):374-376.DOI:10.3760/cma.j.issn.1004-4221.2012.04.023. [8]岳金波,于金明,刘菁,等.图像引导鼻咽癌调强放疗的初步观察[J].中华肿瘤杂志,2008,30(6):479-480.DOI:10.3321/j.issn:0253-3766.2008.06.020. [9]Gilbeau L, Octave Prignot M, Loncol T, et al. Comparison of setup accuracy of three different thermoplastic masks for the treatment of brain and head and neck tumors[J]. Radiother Oncol,2001,58(2):155-162.DOI:10.1016/S0167-8140(00)00280-2. [10]Hurkmans CW,Remeijer P,Lebsque JV,et al. Set-up verification using portal imaging:review of current clinical practice[J]. Radiather Oncol,200l,58(2):105-120.DOI:10.1016/S0167-8140(00)00260-7. [11]徐鹭英,潘建基,王笑良,等.头颈部肿瘤图像引导调强放疗中摆位误差对剂量学的影响研究[J].中华放射肿瘤学杂志,2011,20(6):506-509.DOI:10.3760/cma.j.issn.1004-4221.2011.06.017. [12]林承光,李国文,刘晓臻,等.鼻咽癌调强放射治疗摆位不确定度对危及器官计划体积(PRV)影响的研究[J].癌症,2008,27(3):327-330.DOI:10.3321/j.issn:1000-467X.2008.03.021. [13]王瑾,许峰,柏森,等.千伏级锥形束断层扫描在鼻咽癌适形调强放射治疗中的初步应用[J].癌症,2008,27(7):761-765.DOI:10.3321/j.issn:1000-467X.2008.07.018. [14]肖光莉,丘熹彬,王卫华,等.鼻咽癌调强放疗长期疗效及预后分析[J].中华放射肿瘤学杂志,2012,21(6):488-491.DOI:10.3760/cma.j.issn.1004-4221.2012.06.002. [15]肖光莉,王卫华,丘熹彬,等.176例鼻咽癌调强放疗晚期不良反应分析[J].中华放射肿瘤学杂志,2013,22(1):42-45.DOI:10.3760/cma.j.issn.1004-4221.2013.01.013.