Abstract:Objective The purpose of the study was to use cone beam CT (CBCT) scans to evaluate setup errors in image-guided radiotherapy with thoracic esophageal carcinoma, in order to refer for adaptive radiotherapy. Methods CBCT scans were performed before and at the end of image-guided radiotherapy with 23 thoracic esophageal carcinoma patients. The registration method and setup error in different lesions and treatment weeks were measured. The difference of treatment time was single factor analysis of variance. Results Compared with bone registration and gray value registration, the setup errors in x and z axis have significant differences. Without CBCT, the adequate coverage margins required for the CTV in x, y and z axis with upper, middle and lower esophageal carcinoma were 6 mm, 17 mm, 6 mm;4 mm, 17 mm, 6 mm and 11 mm, 11 mm 4 mm, respectively. The adequate coverage margins of the plan target volume (PTV) were 2 mm, 2 mm and 4 mm in x, y and z axis if the CBCT was applied in irradiation during the image guided radiotherapy. When compared with setup errors at different weeks, no significant difference was found among them in y axis (P=0.001,0.000), but the setup errors of the fifth week in x and z axis were larger significantly than those of other weeks (P=0.858). Conclusions Gray value registration is recommended in image-guided radiotherapy with thoracic esophageal carcinoma. The adequate coverage margins are different in x, y and z axis with different lesions. The coverage margin of the PTV could be reduced significantly as CBCT are applied during the irradiation. The setup errors measured during earlier treatment period can be considered to guide subsequent irradiation. The setup errors in x and z axis become larger during the later irradiation course. Re-simulation should be recommended at the the fifth treatment week.
Shang Kai,Chi Zifeng,Wang Jun et al. The analysis of setup error in image-guided radiotherapy with thoracic esophageal carcinoma [J]. Chinese Journal of Radiation Oncology, 2015, 24(1): 70-73.
[1] Yan D,Vicini F,Wong J,et al.Adaptive radiation therapy[J].Phys Med Biol,1997,42(1):123-132. [2] Bijhold J, van Herk M, Vijlbrief R, et al. Fast evaluation of patient set-up during radiotherapy by aligning features in portal and simulator images[J]. Phys Med Biol,1991,36(2):1665-1679. [3] Van HM.Errors and margins in radiotherapy[J].Semin Radiat Oncol,2004,14(1):52-64.DOI:10.1053/j.semradonc.2003.10.003. [4] 曲颂,朱小东,李龄,等.三种配准方式下腹部肿瘤IGRT摆位误差的比较[J].肿瘤防治研究,2011,38(12):1434-1437. DOI:10.3971/j.issn.1000-8578.2011.12.025. [5] 高超,王澜,迟子锋,等.食管癌三维适形放疗中摆位误差对剂量学影响的研究[J].中华放射肿瘤学杂志,2009,18(4):270-273.DOI:10.3760/cma.j.issn.1004-4221.2009.04.270. [6] Borst GR, Sonke JJ, Betgen A,et al. Kilo-voltage cone-beam computed tomography setup measurements for lung cancer patients:first clinical results and comparison with electronic portal-imaging device[J].Int J Radiat Oncol Biol Phys,2007,68(2):555-561.DOI:10.1016/j.ijrobp.2007.01.014. [7] Hawkins MA, Aitken A, Hansen VN, et al. Set-up errors in radiotherapy for oesophageal cancers—is electronic portal imaging or conebeam more accurate?[J].Radiother Oncol,2011,98(2):249-254.DOI:10.1016/j.radonc.2010.11.002. [8] Kupelian PK, Lee C, Langen KM, et al. Evaluation of image-guidance strategies in the treatment of localized prostate cancer[J]. Int J Radiat Oncol Biol Phys,2008,70(4):1151-1157.DOI:10.1016/j.ijrobp.2007.07.2371. [9] Zeidan OA, Langen KM, Meeks SL, et al. Evaluation of image-guidance protocols in the treatment of head and neck cancers[J]. Int J Radiat Oncol Biol Phys,2007,67(3):670-677.DOI:10.1016/j.ijrobp.2006.09.040. [10] Dieleman E, Senan S, Vincent A, et al. Four-dimensional computed tomographic analysis of esophageal mobility during nomal respiration[J]. Int J Radiat Oncol Biol Phys,2007,67(3):775-780.DOI:10.1016/j.ijrobp.2006.09.054. [11] 梁军,张涛,王文卿,等.图像引导放疗在58例肺癌患者中的应用观察[J].中华放射肿瘤学杂志,2009,18(4):278-280. DOI:10.3760/cma.j.issn.1004-4221.2009.04.278.