Evaluation of extra absorbed dose generated by image guided system of the Cyberknife
DONG Yang, LI Feng-tong, WANG Jing-sheng, YUAN Zhi-yong, SONG Yong-chun, ZHUANG Hong-qing
Department of Radiation Oncology,Tianjin Medical University Cancer Institute and Hospital,Key Laboratory of Cancer Prevention and Therapy,Tianjin 300060, ChinaCorresponding author:LI Feng-tong, Email:ftong_li@yahoo.com.cn
Abstract:Objective To evaluate quantitatively the extra absorbed dose generated by image guided system of the Cyberknife. Methods The exposure parameters and the average frequency of images acquisition during the treatments with G3 Cyberknife in 300 cases with various tumor locations and tracking modes were collected for analysis;The measurements of the absorbed doses in the phantom with 5 points after single exposure generated by image guided system in various exposure parameters were performed with equipment of phantom CIRS Model 002LFC and 002 PRA with ion chamber PTW30010 included. Based on the data we collected andmeasured, the conclusion of how much extra absorbed dose generated by image guided system of Cyberknife the patients received during Cyberknife treatments was drawn. Results With an average fractions of 3.94(the median was 4), the average exposure frequency was 36.5 times for static tracking per patient per fraction, while it was 49.2 times for dynamic tracking. The experimental results with various exposure parameters, positions and tissue densities showed that the minimum absorbed dose after single exposure was 0.5 μGy, while the maximum was 385 μGy. Conclusions The image guided system of the Cyberknife can induce quite low absorbed dose in patient, while providing all three types of image guided function.
DONG Yang,LI Feng-tong,WANG Jing-sheng et al. Evaluation of extra absorbed dose generated by image guided system of the Cyberknife[J]. Chinese Journal of Radiation Oncology, 2013, 22(2): 154-156.
[1] 郝春成.影像引导放射治疗的应用及进展.实用肿瘤学杂志,2010,24:487-489. [2] 董洋,李丰彤,王境生,等.置入软组织金标数目对射波刀系统影像定位精度影响.中华放射肿瘤学杂志,2010,19:465-467. [3] Haigron P, Dillenseger JL, Luo L, et al. Image-guided therapy:evolution and breakthrough. IEEE Eng Med Biol Mag, 2010,29:100-104. [4] DeMarco JJ, Cagnon CH, Cody DD,et al. Estimating radiation doses from multidetector CT using Monte Carlo simulations:effects of different size voxelized patient models on magnitudes of organ and effective dose. Phys Med Biol,2007,52:2583-2597. [5] Wong JR, Grimm L, Uematsu M,et al. Image-guided radiotherapy for prostate cancer by CT-linear accelerator combination:prostate movements and dosimetric considerations. Int J Radiat Oncol Biol Phys,2005,61:561-569. [6] Díaz-Santos CN, Amaro BJA, Cardiel GA,et al. The safety and efficacy of robotic image-guided radiosurgery system treatment for intra-and extracranial lesions:a systematic review of the literature. Radiother Oncol,2008,89:245-253. [7] Ozhasoglu C,Saw CB,Chen H, et al. Synchrony—cyberknife respiratory compensation technology. Med Dosim,2008,33:117-123. [8] Pepin EW,Wu H,Zhang Y,et al. Correlation and prediction uncertainties in the cyberknife synchrony respiratory tracking system. Med Phys,2011,38:4036-4044. [9] Morin O, Gillis A, Chen J,et al.兆伏级锥形束CT:系统说明及IGRT临床应用介绍. 索京涛,陆嘉德,译.中国癌症杂志,2006,16:513-524. [10] 徐志勇,李龙根,周莉钧,等.兆伏级锥形束CT的低剂量旋转出束成像的剂量特性.中华放射肿瘤学杂志,2008,17:120-122. [11] 张玉海,高杨.瓦里安加速器IGRT过程中患者吸收剂量的研究.中国医学物理学杂志,2010,27:2207-2209.