[an error occurred while processing this directive]|[an error occurred while processing this directive]
乳腺癌改良根治术后三种放疗技术的剂量学对比研究
苗俊杰, 徐英杰, 翟医蕊, 门阔, 王淑莲, 戴建荣
国家癌症中心/国家肿瘤临床医学研究中心/中国医学科学院北京协和医学院肿瘤医院放疗科 100021
Dosimetric comparison of three techniques in radiotherapy for breast cancer after modified mastectomy
Miao Junjie, Xu Yingjie, Zhai Yirui, Men Kuo, Wang Shulian, Dai Jianrong
Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/ Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China
Abstract:Objective To analyze and compare the dosimetric differences based on volumetric-modulated arc therapy (VMAT), fixed field intensity-modulated radiotherapy (F_IMRT), and electron irradiation combined with VMAT (E&VMAT) in radiotherapy for breast cancer after modified mastectomy, aiming to provide reference for clinical selection of treatment plan. Methods Ten patients with the left breast cancer who received radiotherapy after modified mastectomy were randomly selected. The target areas included chest wall and supraclavicular region, and the prescribed dose was 43.5Gy in 15 fractions (2.9Gy/F). Based on the Pinnacle3 planning system, the VMAT, F_IMRT and E&VMAT plans (electron beam for chest wall, VMAT for supraclavicular area) were designed for each patient. The conformity and homogeneity of the target areas, the dose of organs at risk and treatment time were compared. Results The VMAT plan could improve the dose distribution of the target areas. The conformity index and homogeneity index of the target dose were significantly better than those of the F_IMRT and E&VMAT plans (all P<0.05). The average dose, V30Gy, V20Gy, V10Gy of the left lung in the VMAT plan were significantly better than those in the F_IMRT and E&VMAT plans (all P<0.05). The V5Gy of the left lung in the VMAT plan was significantly better than that in the F_IMRT plan (P<0.05). There was no statistical difference in the V5Gy of the left lung between the VMAT and E&VMAT plans (P>0.05). The heart, right breast and right lung of the VMAT plan could meet the clinical dose limit requirements. The treatment time of the VMAT, F_IMRT and E&VMAT plans was (326±27) s,(1 082±169) s, and (562±48) s, respectively. Conclusions Compared with the F_IMRT and E&VMAT plans, the VMAT plan has better quality and shorter treatment time. VMAT plan has higher value in clinical application compared with the F_IMRT and E&VMAT plans.
Miao Junjie,Xu Yingjie,Zhai Yirui et al. Dosimetric comparison of three techniques in radiotherapy for breast cancer after modified mastectomy[J]. Chinese Journal of Radiation Oncology, 2021, 30(9): 924-929.
[1] Offersen BV, Boersma LJ, Kirkove C, et al.ESTRO consensus guideline on target volume delineation for elective radiation therapy of early stage breast cancer[J]. Radiother Oncol, 2015, 114(1):3-10.DOI:10.1016/j.radonc.2014.11.030. [2] Chung CS, Harris JR.Post-mastectomy radiation therapy:translating local benefits into improved survival[J]. Breast, 2007, 16(Suppl 2):S78-83.DOI:10.1016/j.breast.2007.07.018. [3] Beckham WA, Popescu CC, Patenaude VV, et al.Is multibeam IMRT better than standard treatment for patients with left-sided breast cancer?[J]. Int J Radiat Oncol Biol Phys, 2007, 69(3):918-924.DOI:10.1016/j.ijrobp.2007.06.060. [4] Liu J, Ng D, Lee J, et al.Chest wall desmoid tumours treated with definitive radiotherapy:a plan comparison of 3D conformal radiotherapy, intensity-modulated radiotherapy and volumetric-modulated arc radiotherapy[J]. Radiat Oncol, 2016, 11:34.DOI:10.1186/s13014-016-0611-0. [5] Liu H, Chen X, He Z, et al.Evaluation of 3D-CRT, IMRT and VMAT radiotherapy plans for left breast cancer based on clinical dosimetric study[J]. Comput Med Imag Graph, 2016, 54:1-5.DOI:10.1016/j.compmedimag.2016.10.001. [6] Palma D, Vollans E, James K, et al.Volumetric modulated arc therapy for delivery of prostate radiotherapy:comparison with intensity-modulated radiotherapy and three-dimensional conformal radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2008, 72(4):996-1001.DOI:10.1016/j.ijrobp.2008.02.047. [7] 郑明志,胡彩容,程燕铭,等.半弧和剪刀形切线弧技术在左侧乳腺癌根治术后放疗中的剂量学研究[J]. 肿瘤学杂志,2018, 24(5):470-475.DOI:10.11735/j.issn.1671-170X.2018.05.B012. Zheng MZ, Hu CR, Cheng YM, et al.Dosimetric comparison of semi-arc and tangent-arc techniques in volumetric modulated arc therapy for left breast cancer[J]. J Chin Oncol, 2018, 24(5):470-475.DOI:10.11735/j.issn.1671-170X.2018.05.B012. [8] 王承伟,许刚,薛辉,等.乳腺癌改良根治术后不同放疗技术的剂量学比较及不良反应观察[J]. 甘肃医药,2016, 35(12):881-884.DOI:10.15975/j.cnki.gsyy.2016.12.001. Wang CW, Xu G, Xue H, et al.Comparison of dosimetric parameter and adverse reaction analysis in different radiation technology in the patients received modi-fied radical mastectomy for breast cancer[J]. Gansu Med J, 2016, 35(12):881-884.DOI:10.15975/j.cnki.gsyy.2016.12.001. [9] 谢琛,张怀文,洪潮,等.左侧乳腺癌改良根治术后常用调强照射技术剂量学比较[J]. 实用癌症杂志, 2018, 33(12):1941-1946.DOI:10.3969/j.issn.1001-5930.2018.12.008. Xie C, Zhang H, Hong C, et al.Dosimetric comparison of intensity-modulated radiation therapies for left breast cancer receiving post-mastectpmy[J]. Pract J Cancer, 2018, 33(12):1941-1946.DOI:10.3969/j.issn.1001-5930.2018.12.008. [10] Dogan N, Cuttino L, Lloyd R, et al.Optimized dose coverage of regional lymph nodes in breast cancer:the role of intensity-modulated radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2007, 68(4):1238-1250.DOI:10.1016/j.ijrobp.2007.03.059. [11] Coles CE, Moody AM, Wilson CB, et al.Reduction of radiotherapy-induced late complications in early breast cancer:the role of intensity-modulated radiation therapy and partial breast irradiation.Part Ⅱ—Radiotherapy strategies to reduce radiation-induced late effects[J]. Clin Oncol (R Coll Radiol), 2005, 17(2):98-110.DOI:10.1016/j.clon.2004.08.010. [12] van der Laan HP, Korevaar EW, Dolsma WV, et al.Minimising contralateral breast dose in post-mastectomy intensity-modulated radiotherapy by incorporating conformal electron irradiation[J]. Radiother Oncol, 2010, 94(2):235-240.DOI:10.1016/j.radonc.2009.12.015. [13] Kimura T, Togami T, Takashima H, et al.Radiation pneumonitis in patients with lung and mediastinal tumours:a retrospective study of risk factors focused on pulmonary emphysema[J]. Br J Radiol, 2012, 85(1010):135-141.DOI:10.1259/bjr/32629867. [14] Wang S, Liao Z, Wei X, et al.Analysis of clinical and dosimetric factors associated with treatment-related pneumonitis (TRP) in patients with non-small-cell lung cancer (NSCLC) treated with concurrent chemotherapy and three-dimensional conformal radiotherapy (3D-CRT)[J]. Int J Radiat Oncol Biol Phys, 2006, 66(5):1399-1407.DOI:10.1016/j.ijrobp.2006.07.1337. [15] Blom Goldman U, Wennberg B, Svane G, et al.Reduction of radiation pneumonitis by V20-constraints in breast cancer[J]. Radiat Oncol, 2010, 5:99.DOI:10.1186/1748-717x-5-99. [16] Kaufman EL, Jacobson JS, Hershman DL, et al.Effect of breast cancer radiotherapy and cigarette smoking on risk of second primary lung cancer[J]. J Clin Oncol, 2008, 26(3):392-398.DOI:10.1200/jco.2007.13.3033. [17] Stovall M, Smith SA, Langholz BM, et al.Dose to the contralateral breast from radiotherapy and risk of second primary breast cancer in the WECARE study[J]. Int J Radiat Oncol Biol Phys, 2008, 72(4):1021-1030.DOI:10.1016/j.ijrobp.2008.02.040. [18] Prochazka M, Hall P, Gagliardi G, et al.Ionizing radiation and tobacco use increases the risk of a subsequent lung carcinoma in women with breast cancer:case-only design[J]. J Clin Oncol, 2005, 23(30):7467-7474.DOI:10.1200/jco.2005.01.7335. [19] Meeks SL, Buatti JM, Bova FJ, et al.Potential clinical efficacy of intensity-modulated conformal therapy[J]. Int J Radiat Oncol Biol Phys, 1998, 40(2):483-495.DOI:10.1016/s0360-3016(97)00819-5. [20] Di Betta E, Fariselli L, Bergantin A, et al.Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments[J]. Med Phys, 2010, 37(7):3587-3594.DOI:10.1118/1.3447724. [21] Skov KA.Radioresponsiveness at low doses:hyper-radiosensitivity and increased radioresistance in mammalian cells[J]. Mutat Res, 1999, 430(2):241-253.DOI:10.1016/s0027-5107(99)00136-0. [22] 郭晨雷,徐英杰,戴建荣.乳腺癌容积调强弧形治疗的射野边界外放方法[J]. 中华放射肿瘤学杂志,2018, 27(9):845-849.DOI:10.3760/cma.j.issn.1004-4221.2018.09.012. Guo C, Xu Y, Dai J.Margin expansion for treatment field of volumetric modulated arc therapy for breast cancer[J]. Chin J Radiat Oncol, 2018, 27(9):845-849.DOI:10.3760/cma.j.issn.1004-4221.2018.09.012. [23] Lizondo M, Latorre-Musoll A, Ribas M, et al.Pseudo skin flash on VMAT in breast radiotherapy:Optimization of virtual bolus thickness and HU values[J]. Phys Med, 2019, 63:56-62.DOI:10.1016/j.ejmp.2019.05.010. [24] Giorgia N, Antonella F, Alessandro C, et al.Planning strategies in volumetric modulated are therapy for breast[J]. Med Phys, 2011, 38(7):4025-4031.DOI:10.1118/1.3598442. [25] Hattel SH, Andersen PA, Wahlstedt IH, et al.Evaluation of setup and intrafraction motion for surface guided whole-breast cancer radiotherapy[J]. J Appl Clin Med Phys, 2019, 20(6):39-44.DOI:10.1002/acm2.12599.