基于四维CT的平静呼吸状态下肾脏各方向运动幅度及影响因素分析
马茗微1, 高献书1, 李洪振1, 赵波2,3, 张敏1, 刘思伟1, 秦尚彬1, 亓昕1, 白赟1
1北京大学第一医院放疗科 100034;
2清华大学工程物理系,北京 100084;
3清华大学粒子技术与辐射成像教育部重点实验室,北京100084
Kidney motion in each direction and influencing factors derived from four dimensional computed tomography under free-breathing condition
Ma Mingwei1, Gao Xianshu1, Li Hongzhen1, Zhao Bo2,3, Zhang Min1, Liu Siwei1, Qin Shangbin1, Qi Xin1, Bai Yun1
1Department of Radiation Oncology, Peking University First Hospital, Beijing 100034, China;
2Department of Engineering Physics, Tsinghua University, Beijing 100084, China;
3Key Laboratory of Particle & Radiation Imaging, Ministry of Education, Tsinghua University, Beijing 100084, China
全文: PDF (0 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      背景资料
摘要 目的 探索平静呼吸状态下正常肾脏在三维方向的运动幅度及其相关的影响因素。方法 收集2018—2019年间行四维CT且能够平静呼吸的 28例患者数据,肿瘤类别包括肝肿瘤、胰腺肿瘤或肺肿瘤。腹窗条件下逐层、逐呼吸时相勾画肾脏外轮廓并找到几何中心及三维方向坐标数值;计算左、右肾各个方向及三维方向位移。记录周围脏器体积及患者年龄、性别、身高、体重指数。采用t检验或非参数检验比较差异。结果 左、右肾脏上下方向运动幅度大,分别为(8.39±3.18)、(7.71±3.55)mm。男性双肾在左右、上下及三维方向平均运动幅度均大于女性(P<0.05),身高>165cm者亦大于≤165cm者(P<0.05)。超重者仅左肾左右、前后方向运动幅度大于未超重患者(P<0.05)。左肾体积>180cm3者其前后方向运动幅度较大(P=0.014)。年龄与各方向运动均相近(P>0.05)。结论 肾脏运动主要表现在上下方向,男性、身高高者运动幅度大,需格外注意使用控制呼吸运动的相关装置以降低正常组织损伤。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
马茗微
高献书
李洪振
赵波
张敏
刘思伟
秦尚彬
亓昕
白赟
关键词 肾脏器官运动放疗体层摄影术X线计算机四维    
AbstractObjective To explore the amplitude of normal kidney motion in the 3D direction and its influencing factors under free-breathing condition. Methods Clinical data of 28 patients with a KPS score≥80 who received 4D CT scan from March 2018 to March 2019 were collected. All patients were diagnosed with liver, pancreatic or lung tumors. The kidney was outlined and the geometric center and 3D coordinate values were recorded. The motion of bilateral kidneys in each direction and the 3D direction was calculated. The volume of kidney and surrounding organs, age, sex, height and body mass index (BMI) were recorded. Clinical data were statistically compared by t-test or nonparametric test. Results The motion of the left and right kidneys in the the sup-inf (SI) direction were the largest up to (8.39±3.18) mm and (7.71±3.55) mm. The motion amplitudes of bilateral kidneys in male patients were significantly larger than those of the female counterparts in the left-right (LR), SI and 3D directions (all P<0.05). The motion amplitudes of bilateral kidneys in patients taller than 165cm were significantly larger than those of their counterparts with a height of ≤165cm (all P<0.05). Patients with a BMI≥25kg/m2had significantly larger motion amplitudes of the left kidney in the LR and ant-post (AP) directions compared with those of normal weight counterparts (all P<0.05). The motion amplitude of the left kidney in the AP direction in patients with the left kidney volume of >180cm3 was significantly larger than that of patients with smaller left kidney volume (P=0.014). Age was not significantly associated with kidney motion in each direction (P>0.05). Conclusions Kidney motion mainly occurs in the SI direction. The kidney motion amplitudes in male and taller patients are larger. Special attention should be paid to the use of breath motion control device to decrease the normal tissue damage.
Key wordsKidney    Organ motion    Radiotherapy    Tomography    X-ray computed    four-dimensional   
收稿日期: 2019-07-07     
基金资助:北京大学第一医院种子基金(2018SF043)
通讯作者: 高献书,Email:doctorgaoxs@126.com   
引用本文:   
马茗微,高献书,李洪振等. 基于四维CT的平静呼吸状态下肾脏各方向运动幅度及影响因素分析[J]. 中华放射肿瘤学杂志, 2021, 30(5): 481-485.
Ma Mingwei,Gao Xianshu,Li Hongzhen et al. Kidney motion in each direction and influencing factors derived from four dimensional computed tomography under free-breathing condition[J]. Chinese Journal of Radiation Oncology, 2021, 30(5): 481-485.
链接本文:  
http://journal12.magtechjournal.com/Jweb_fszlx/CN/10.3760/cma.j.cn113030-20190707-00263     或     http://journal12.magtechjournal.com/Jweb_fszlx/CN/Y2021/V30/I5/481
京公网安备11010502022167号
版权所有 © 2010《中华放射肿瘤学杂志》编辑部
地址:北京朝阳区潘学园南里17号 中国医学科学院肿瘤医院(100021)
电话:010-67700737,87788294 Email: cjron@cmaph.org
本系统由北京玛格泰克科技发展有限公司设计开发 技术支持:Support@magtech.com.cn