[an error occurred while processing this directive]
中华放射肿瘤学杂志
   2025年4月17日 星期四     首 页 |  期刊介绍  |  编 委 会  |  投稿指南  |  期刊订阅  |  广告合作  |  学术影响  |  收录情况  |  联系我们  |  English
中华放射肿瘤学杂志  2020, Vol. 29 Issue (5): 396-400    DOI: 10.3760/cma.j.cn113030-20190624-00016
综述 最新目录| 下期目录| 过刊浏览| 高级检索 [an error occurred while processing this directive]|[an error occurred while processing this directive]
MRI-Linac剂量测量研究进展
傅佳棋1, 倪成1, 付杰2
1上海交通大学生物医学工程学院 200030;
2上海市第六人民医院放疗科 200232
Research progress in dosimetry with MRI-Linac
Fu Jiaqi1, Ni Cheng1, Fu Jie2
1School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai 200030, China;
2Department of Radiotherapy,Shanghai Sixth People′s Hospital, Shanghai 200232, China
全文: PDF (0 KB)   HTML (1 KB) 
输出: BibTeX | EndNote (RIS)      背景资料
摘要 MRI-Linac一体机实现了MRI实时引导放疗,加快了精确放疗进展。磁场中电子受到洛伦兹力作用,尤其是在组织-空气界面处出现电子回旋效应,改变了原有的电子平衡状态,这给MRI-Linac下的剂量测量带来挑战。近年来通过蒙特卡洛模拟和实验测量开展的系列研究表明常规剂量测量装置进行磁性材料替换后,即可以用于MRI-Linac下的剂量测量,但需要根据磁场强度、测量装置摆放角度、测量装置类型引入相应的修正因子。MRI-Linac下剂量测量的规范化、流程化以及实时剂量测量有待进一步研究。
服务
把本文推荐给朋友
加入我的书架
加入引用管理器
E-mail Alert
RSS
作者相关文章
傅佳棋
倪成
付杰
关键词 MRI-Linac洛伦兹力剂量测量    
Abstract:The integration of MRI and linac has realized real-time MRI-guided radiotherapy and accelerated the progress of precision radiotherapy. Electrons are subjected to Lorentz force in the magnetic field, especially the electron cyclotron effect occurs at the tissue-air interface, which changes the original electron equilibrium state and brings challenges to dosimetry with MRI-Linac. In recent years, a series of studies carried out through Monte Carlo simulation and experimental measurement have suggested that the conventional dosimetry devices can be used for the dosimetry with MRI-Linac after replacing the magnetic materials, but corresponding correction factors should be introduced according to the magnetic field intensity, placement angle of the measuring device, type of the measuring device. The standardization, streamlining, and real-time dosimetry with MRI-Linac need to be further studied.
Key wordsMRI-Linac    Lorentz force    Dosimetry   
收稿日期: 2019-06-24     
基金资助:上海申康医院发展中心促进市级医院临床技能与临床创新能力三年行动计划(16CR3112B);上海市卫生和计划生育委员会科研课题青年项目(20184Y0229)
通讯作者: 付杰,Email:fujie74@sjtu.edu.cn   
引用本文:   
傅佳棋,倪成,付杰. MRI-Linac剂量测量研究进展[J]. 中华放射肿瘤学杂志, 2020, 29(5): 396-400.
Fu Jiaqi,Ni Cheng,Fu Jie. Research progress in dosimetry with MRI-Linac[J]. Chinese Journal of Radiation Oncology, 2020, 29(5): 396-400.
链接本文:  
http://journal12.magtechjournal.com/Jweb_fszlx/CN/10.3760/cma.j.cn113030-20190624-00016     或     http://journal12.magtechjournal.com/Jweb_fszlx/CN/Y2020/V29/I5/396
京公网安备11010502022167号
版权所有 © 2010《中华放射肿瘤学杂志》编辑部
地址:北京朝阳区潘学园南里17号 中国医学科学院肿瘤医院(100021)
电话:010-67700737,87788294 Email: cjron@cmaph.org