Abstract:Objective To compare the dosimetric data between preoperative plans and postoperative verification in computed tomography (CT)-guided and 3D-printing non-coplanar template-assisted 125I seed implantation for head and neck tumor, aiming to explore the safety, feasibility and accuracy of the individualized template design method. Methods A total of 42 patients with recurrent/metastatic malignant head and neck tumor admitted toPeking University Third Hospitalfrom January to December 2016 were recruited in this study. A prescribed dose of 110-160Gy was adopted.3D-printing non-coplanar templates were designed for 42 cases. The dosimetric parameters including D90,minimum peripheral dose (mPD),V100,V150,V200,conformal index (CI),external index (EI) and homogeneity index (HI) were statistically compared before and after surgery. Results All templates were properly implanted intraoperatively. Compared with preoperative planning, postoperative D90,V100,CI,EI and HI did not significantly differ (P=0.490, 0.407, 0.893, 0.143 and 0.079), whereas mPD,V150 and V200 significantly differed (P=0.036, 0.007 and 0.000). Conclusion After postoperative verification, the main dosimetric parameters have high therapeutic accuracy and properly match with preoperative planning, which can meet clinical requirements.
Cui Yue,Sun Haitao,Jiang Yuliang et al. 3D-printing non-coplanar template assisted 125I seed implantation for head and neck tumor:individualized template design and application[J]. Chinese Journal of Radiation Oncology, 2020, 29(1): 43-46.
[1]Meng N,Jiang YL,Wang JJ,et al. Permanent implantation of iodine-125 seeds as a salvage therapy for recurrent head and neck carcinoma after radiotherapy[J]. Cancer Invest,2012,30(3):236-242. DOI:10.3109/07357907.2012.654869.
[2]Wang ZM,Lu J,Liu T,et al. CT-guided interstitial brachytherapy of inoperable non-small cell lung cancer[J]. Lung Cancer,2011,74(2):253-257. DOI:10.1016/j.lungcan.2011.03.006.
[3]Wang H,Wang JJ,Jiang YL,et al. The investigation of 125I seed implantation as a salvage modality for unresectable pancreatic carcinoma[J]. J Exp Clin Cancer Res,2013,32(1):106-113. DOI:10.1186/1756-9966-32-106.
[4]Wang JJ,Yuan HS,Li JN,et al. Interstitial permanent implantation of 125I seeds as salvage therapy for re-recurrent rectal carcinoma[J]. Int J Colorectal Dis,2009,24(4):391-399. DOI:10.1007/s00384-008-0628-4.
[5]刘树铭,张建国,黄明伟,等. 个体化模板辅助颅底区永久性组织间近距离治疗的可行性研究[J]. 中华放射医学与防护杂志,2013,33(1):42-45. DOI:10.3760/cma.j.issn.0254-5098.2013.01.011.
Liu S, Zhang J, Huang M, et al. Feasibility of permanent interstitial brachytherapy for skull base region through individual template assistance[J]. Chin J Radiol Med Prot, 2013,33(1):42-45. DOI:10.3760/cma.j.issn.0254-5098.2013.01.011.
[6]赵一姣,王勇,黄明伟,等. 近距离放射治疗用个性化导板的数字化设计方法[J]. 中华口腔医学杂志,2014,49(2):115-118. DOI:10.3760/cma.j.issn.1002-0098.2014.02.011.
Zhao Y, Wang Y, Huang M, et al. Method about digital design of individual template for brachytherapy[J]. Chin J Stomal, 2014,49(2):115-118. DOI:10.3760/cma.j.issn.1002-0098.2014.02.011.
[7]赵楠,杨瑞杰,王俊杰.125I放射性粒子植入计划定制研究[J]. 中华放射医学与防护杂志,2014,(1):54-58. DOI:10.3760/cma.j.issn.0254-5098.2014.01.015.
Zhao N, Yang R, Wang J. Customized planning for radioactive 125I seed implantation[J]. Chin J Radiol Med Prot,2014,(1):54-58. DOI:10.3760/cma.j.issn.0254-5098.2014.01.015.
[8]Nag S,Beyer D,Friedland J,et al. American brachytherapy society (ABS) recommendations for transperineal permanent brachytherapy of prostate cancer[J]. Int J Radiat Oncol Biol Phys,1999,44(4):789-799. DOI:10.1016/s0360-3016(99)00069-3.
[9]霍彬,侯朝华,叶剑飞,等. CT引导术中实时计划对胸部肿瘤125Ⅰ粒子植入治疗的价值[J]. 中华放射肿瘤学杂志,2013,22(5):400-402. DOI:10.3760/cma.j.issn.1004-4221.2013.05.019.
Huo B, Hou Z, Ye J, et al. The study of intraoperative real-time planning by CT-guided in 125I seed implantation for thoracic malignancies[J]. Chin J Radiat Oncol, 2013,22(5):400-402. DOI:10.3760/cma.j.issn.1004-4221.2013.05.019.
[10]孙海涛,姚丽红,王俊杰,等.3D打印非共面模板引导125I粒子组织间近距离治疗盆腔肿瘤个体化设计[J]. 中华放射医学与防护杂志,2017,37(7):485-489. DOI:10.3760/cma.j.issn.0254-5098.2017.07.002.
Sun H, Yao L, Wang J, et al. 3D-printing non-coplanar template assisted 125I seed for pelvic tumor:individual template design method[J]. Chin J Radiol Med Prot, 2017,37(7):485-489. DOI:10.3760/cma.j.issn.0254-5098.2017.07.002.
[11]姜玉良,李宾,吉喆,等.3D打印个体化非共面模板辅助粒子植入时定位与复位误差研究[J]. 中华放射医学与防护杂志,2016,36(12):913-916. DOI:10.3760/cma.j.issn.0254-5098.2016.12.007.
Jiang Y, Li B, Ji Z, et al. Analysis of position errors of 3D printing individual non-coplanar template for radioactive seed implantation for malignant tumor[J]. Chin J Radiol Med Prot, 2016,36(12):913-916. DOI:10.3760/cma.j.issn.0254-5098.2016.12.007.
[12]李客楼,李宗安,朱莉娅,等.3D打印技术在医疗领域的应用进展[J]. 机械设计与制造工程,2016,45(9):11-16. DOI:10.3969/j.issn.2095-509X.2016.09.002.
Li K, Li Z, Zhu L, et al. Application of 3D printing technology in medical field[J]. Mach Des Manuf Eng, 2016,45(9):11-16. DOI:10.3969/j.issn.2095-509X.2016.09.002.