Abstract:Radiation pneumonia is a side effect that cannot be ignored in the current radiation therapy for lung cancer. At present, there are studies and reports of the introduction of functional imaging technology into lung cancer radiotherapy plans, in which 4DCT has better application prospects in radiotherapy for lung cancer because of its advantages of simple operation, high spatial resolution and no additional cost, etc. Compared with single-photon emission computed tomography (SPECT)-CT, positron emission tomography (PET)-CT, MRI has a better application prospect in radiotherapy of lung cancer. The use of 4DCT to obtain the patient's lung function status can predict radiation pulmonary toxicity and assist clinicians to deliver prompt interventions. Moreover, it can help carry out radiotherapy for functional lung avoidance, mitigate the damage of normal lung tissues, and alleviate chest toxicity, which may have wider application value in the future. In this article, research progress on functional lung imaging algorithms based on 4DCT and the application of radiation therapy for lung cancer was reviewed.
Zhong Wenjing,Li Ying,Cui Haixia. Application of 4DCT-based lung functional imaging in radiotherapy for lung cancer[J]. Chinese Journal of Radiation Oncology, 2023, 32(5): 481-487.
[1] Mazeron R, Etienne-Mastroianni B, Pérol D, et al.Predictive factors of late radiation fibrosis: a prospective study in non-small cell lung cancer[J]. Int J Radiat Oncol Biol Phys, 2010,77(1):38-43. DOI: 10.1016/j.ijrobp.2009.04.019. [2] Ding X, Ji W, Li JL, et al.Radiation recall pneumonitis induced by chemotherapy after thoracic radiotherapy for lung cancer[J]. Radiat Oncol, 2011,6:24. DOI: 10.1186/1748-717X-6-24. [3] Mehta V.Radiation pneumonitis and pulmonary fibrosis in non-small-cell lung cancer: pulmonary function, prediction, and prevention[J]. Int J Radiat Oncol Biol Phys, 2005,63(1):5-24. DOI: 10.1016/j.ijrobp.2005.03.047. [4] Faught AM, Yamamoto T, Castillo R, et al.Evaluating which dose-function metrics are most critical for functional-guided radiation therapy[J]. Int J Radiat Oncol Biol Phys, 2017,99(1):202-209. DOI: 10.1016/j.ijrobp.2017.03.051. [5] Yamamoto T, Kabus S, von Berg J, et al. Impact of four-dimensional computed tomography pulmonary ventilation imaging-based functional avoidance for lung cancer radiotherapy[J]. Int J Radiat Oncol Biol Phys, 2011,79(1):279-288. DOI: 10.1016/j.ijrobp.2010.02.008. [6] Bates EL, Bragg CM, Wild JM, et al.Functional image-based radiotherapy planning for non-small cell lung cancer: a simulation study[J]. Radiother Oncol, 2009,93(1):32-36. DOI: 10.1016/j.radonc.2009.05.018. [7] Hodge CW, Tomé WA, Fain SB, et al.On the use of hyperpolarized helium MRI for conformal avoidance lung radiotherapy[J]. Med Dosim, 2010,35(4):297-303. DOI: 10.1016/j.meddos.2009.09.004. [8] Ford EC, Mageras GS, Yorke E, et al.Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning[J]. Med Phys, 2003,30(1):88-97. DOI: 10.1118/1.1531177. [9] Mageras GS, Pevsner A, Yorke ED, et al.Measurement of lung tumor motion using respiration-correlated CT[J]. Int J Radiat Oncol Biol Phys, 2004,60(3):933-941. DOI: 10.1016/j.ijrobp.2004.06.021. [10] Uchida Y, Tsugawa T, Tanaka-Mizuno S, et al.Exclusion of emphysematous lung from dose-volume estimates of risk improves prediction of radiation pneumonitis[J]. Radiat Oncol, 2017,12(1):160. DOI: 10.1186/s13014-017- 0891-z. [11] 郭振江, 郑力豪, 么志军, 等. 胸部放射治疗致肺癌患者急性放射性肺炎的影响因素分析[J].河南医学研究,2021,30(23):4263-4265. DOI: 10.3969/j.issn.1004-437X.2021.23.009. Guo ZJ, Zheng LH, Yao ZJ, et al.Influencing factors of acute radiation pneumonia in patients with lung cancer caused by thoracic radiotherapy[J]. Henan Med Res,2021,30(23):4263-4265. DOI: 10.3969/j.issn.1004-437X.2021.23.009. [12] 张林会, 陈宏. 放射性肺损伤相关危险因素的研究进展[J].医学综述,2021,27(4):727-732. DOI: 10.3969/j.issn.1006-2084.2021.04.020. Zhang LH, Chen H.Research progress of risk factors for radiation-induced lung injury[J]. Med Recapitulate,2021,27(4):727-732. DOI: 10.3969/j.issn.1006-2084.2021.04.020. [13] Graham MV, Purdy JA, Emami B, et al.Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer (NSCLC)[J]. Int J Radiat Oncol Biol Phys, 1999,45(2):323-329. DOI: 10.1016/s0360-3016(99)00183-2. [14] 张国前, 张书旭. 功能成像及其在肺癌放疗中的应用研究[J].中国医学物理学杂志,2011,28(3):2584-2587,2596. DOI: 10.3969/j.issn.1005-202X.2011.03.002. Zhang GQ, Zhang SX.The study of functional imaging and it's application in thoracic cancer radiotherapy[J]. Chin J Med Phys,2011,28(3):2584-2587,2596. DOI: 10.3969/j.issn.1005-202X.2011.03.002. [15] Simon BA.Non-invasive imaging of regional lung function using X-ray computed tomography[J]. J Clin Monit Comput, 2000,16(5-6):433-442. DOI: 10.1023/a:1011444826908. [16] Guerrero T, Sanders K, Castillo E, et al.Dynamic ventilation imaging from four-dimensional computed tomography[J]. Phys Med Biol, 2006,51(4):777-791. DOI: 10.1088/0031-9155/51/4/002. [17] Castillo R, Castillo E, Martinez J, et al.Ventilation from four-dimensional computed tomography: density versus Jacobian methods[J]. Phys Med Biol, 2010,55(16):4661-4685. DOI: 10.1088/0031-9155/55/16/004. [18] Reinhardt JM, Ding K, Cao K, et al.Registration-based estimates of local lung tissue expansion compared to xenon CT measures of specific ventilation[J]. Med Image Anal, 2008,12(6):752-763. DOI: 10.1016/j.media.2008.03.007. [19] Du KF, Bayouth JE, Cao KL, et al.Reproducibility of registration-based measures of lung tissue expansion[J]. Med Phys, 2012,39(3):1595-1608. DOI: 10.1118/1.3685589. [20] Kipritidis J, Hofman MS, Siva S, et al.Estimating lung ventilation directly from 4D CT hounsfield unit values[J]. Med Phys, 2016,43(1):33. DOI: 10.1118/1.4937599. [21] Hegi-Johnson F, Keall P, Barber J, et al.Evaluating the accuracy of 4D-CT ventilation imaging: first comparison with Technegas SPECT ventilation[J]. Med Phys, 2017,44(8):4045-4055. DOI: 10.1002/mp.12317. [22] Li M, Castillo E, Zheng XL, et al.Modeling lung deformation: a combined deformable image registration method with spatially varying Young's modulus estimates[J]. Med Phys, 2013,40(8):081902. DOI: 10.1118/1.4812419. [23] Jafari P, Yaremko BP, Parraga G, et al.4DCT ventilation map construction using biomechanics-base image registration and enhanced air segmentation[J]. Annu Int Conf IEEE Eng Med Biol Soc, 2019,2019:6263-6266. DOI: 10.1109/EMBC.2019.8857931. [24] Szmul A, Matin T, Gleeson FV, et al.Patch-based lung ventilation estimation using multi-layer supervoxels[J]. Comput Med Imaging Graph, 2019,74:49-60. DOI: 10.1016/j.compmedimag.2019.04.002. [25] 薛鹏. 肺部4D CT图像配准及其在呼吸运动估计和通气量估计中的应用研究[D].山东:山东大学, 2021. Xue P.Lung 4D CT image registration and its application in respiratory motion estimation and ventilation estimation[D]. Shandong: Shandong University, 2021. [26] Zhong YC, Vinogradskiy Y, Chen LY, et al.Technical note: deriving ventilation imaging from 4DCT by deep convolutional neural network[J]. Med Phys, 2019,46(5):2323-2329. DOI: 10.1002/mp.13421. [27] Liu ZQ, Miao JJ, Huang P, et al.A deep learning method for producing ventilation images from 4DCT: first comparison with technegas SPECT ventilation[J]. Med Phys, 2020,47(3):1249-1257. DOI: 10.1002/mp.14004. [28] 张书旭, 余辉, 林生趣, 等. 基于4D-CT和变形图像配准获取肺通气功能的三维分布[J].中国医疗设备,2013,(11):19-22. DOI: 10.3969/j.issn.1674-1633.2013.11.006. Zhang SX, Yu H, Lin SQ, et al.Study on 3D distribution of pulmonary ventilation based on 4D-CT and deformation image registration[J]. Chin Med Dev,2013,(11):19-22. DOI: 10.3969/j.issn.1674-1633.2013.11.006. [29] Mounessi FS, Eckardt J, Holstein A, et al.Image-based lung functional radiotherapy planning for non-small cell lung cancer[J]. Strahlenther Onkol, 2020,196(2):151-158. DOI: 10.1007/s00066-019-01518-6. [30] Seppenwoolde Y, De Jaeger K, Boersma LJ, et al.Regional differences in lung radiosensitivity after radiotherapy for non-small-cell lung cancer[J]. Int J Radiat Oncol Biol Phys, 2004,60(3):748-758. DOI: 10.1016/j.ijrobp.2004.04.037. [31] Vinogradskiy Y, Castillo R, Castillo E, et al.Use of 4-dimensional computed tomography-based ventilation imaging to correlate lung dose and function with clinical outcomes[J]. Int J Radiat Oncol Biol Phys, 2013,86(2):366-371. DOI: 10.1016/j.ijrobp.2013.01.004. [32] Patton TJ, Gerard SE, Shao W, et al.Quantifying ventilation change due to radiation therapy using 4DCT Jacobian calculations[J]. Med Phys, 2018,45(10):4483-4492. DOI: 10.1002/mp.13105. [33] Vinogradskiy YY, Castillo R, Castillo E, et al.Use of weekly 4DCT-based ventilation maps to quantify changes in lung function for patients undergoing radiation therapy[J]. Med Phys, 2012,39(1):289-298. DOI: 10.1118/1.3668056. [34] Faught AM, Yamamoto T, Castillo R, et al.Evaluating which dose-function metrics are most critical for functional-guided radiation therapy[J]. Int J Radiat Oncol Biol Phys, 2017,99(1):202-209. DOI: 10.1016/j.ijrobp.2017.03.051. [35] Yaremko BP, Guerrero TM, Noyola-Martinez J, et al.Reduction of normal lung irradiation in locally advanced non-small-cell lung cancer patients, using ventilation images for functional avoidance[J]. Int J Radiat Oncol Biol Phys, 2007,68(2):562-571. DOI: 10.1016/j.ijrobp.2007.01.044. [36] Waxweiler T, Schubert L, Diot Q, et al.A complete 4DCT-ventilation functional avoidance virtual trial: developing strategies for prospective clinical trials[J]. J Appl Clin Med Phys, 2017,18(3):144-152. DOI: 10.1002/acm2.12086. [37] Vinogradskiy Y, Castillo R, Castillo E, et al.Results of a multi-institutional phase 2 clinical trial for 4DCT-ventilation functional avoidance thoracic radiation therapy[J]. Int J Radiat Oncol Biol Phys, 2022,112(4):986-995. DOI: 10.1016/j.ijrobp.2021.10.147. [38] 张书旭, 周凌宏, 徐海荣, 等. 4D-CT重建及其应用研究新进展[J].中国医学物理学杂志,2009,26(2):1046-1050. Zhang SX, Zhou LH, Xu HR, et al.New advance on 4D-CT reconstruction and it's application[J]. Chin J Med Phys,2009,26(2):1046-1050. [39] Porter EM, Myziuk NK, Quinn TJ, et al.Synthetic pulmonary perfusion images from 4DCT for functional avoidance using deep learning[J]. Phys Med Biol, 2021,66(17).DOI: 10.1088/1361-6560/ac16ec. [40] Ireland RH, Tahir BA, Wild JM, et al.Functional image-guided radiotherapy planning for normal lung avoidance[J]. Clin Oncol (R Coll Radiol), 2016,28(11):695-707. DOI: 10.1016/j.clon.2016.08.005.