Analysis of the rectum and bladder changes in prostate precise radiotherapy under the bowel and bladder preparation
Li Ting1,2, Guo Yujun1,2, Yang Xin1, Wu Manli1,3, He Mengxue1, Dai Xinyi1,2, Tian Yue1,2, Zhang Shujing1,2, Mai Xiuying1, He Liru1, Huang Sijuan1
1State Key Laboratory of Oncology in South China, Guangdong Key Laboratory of Nasopharyngeal Carcinoma Diagnosis and Therapy, Sun Yat-sen University Cancer Center, Guangzhou 510060, China; 2Guangzhou Xinhua College,Guangzhou 510520,China; 3Department of Radiation Oncology, Anhui Wanbei Coal-Electricity Group General Hospital (The Third Affiliated Hospital of Bengbu Medical College), Suzhou 234000, China
Abstract:Objective To analyze the clinically acceptable and reproducible bladder and rectum volumes of prostate cancer patients during radiotherapy under bladder and bowel preparation, aiming to provide quantitative indicators for bowel and bladder preparation before and after radiotherapy. Methods Clinical data of 275 prostate cancer patients with strict bladder and bowel preparation and completion of whole course radical radiotherapy at Sun Yat-sen University Cancer Center from April 2015 to December 2020 were retrospectively analyzed. Patients were scanned with cone beam CT (CBCT) before each treatment and the setup error was recorded. Sixty-six patients were selected by simple random sampling and the bladder and rectum on daily CBCT was outlined using MIM software. The relationship between the ratio of daily bladder or rectum volume to the planned bladder or rectum volume (relative value of volume) and setup error was analyzed. Quantitative data were expressed as mean±SD. Normally distributed data were analyzed by paired t-test while non-normally distributed data were assessed by Kruskal-Wallis test. Results The bladder and rectum volume on planning CT were (370.87±110.04) ml and (59.94±25.07) ml of 275 patients. The bladder and rectum volumes on planning CT were (357.51±107.38) ml and (65.28±35.37) ml respectively of the 66 selected patients with 1611 sets of CBCT images. And the bladder and rectum volumes on daily CBCT were (258.96±120.23) ml and (59.95 ± 30.40) ml. The bladder volume of patients was decreased by 3.59 ml per day on average during the treatment and 0.37 ml for the rectum volume. According to the bladder volume on planning CT, all patients were divided into three groups: <250 ml, 250-450 ml and >450 ml groups. The relative value of volume in the 250-450 ml group during the course of radiotherapy was the smallest. And the setup error in the superior and inferior (SI) direction was (0.28±0.24) cm and (0.19±0.17) cm in the left and right (LR) direction, significantly lower than those in the other two groups (both P≤0.027). According to the rectum volume on planning CT, all patients were divided into four groups: <50 ml, 50-<80 ml, 80-120 ml and >120 ml groups. The <50 ml group had the smallest relative value of volume during radiotherapy, and the setup error in the SI direction was (0.26±0.22) cm and (0.24±0.22) cm in the anterior and posterior (AP) direction, significantly smaller than those in the other groups (both P≤0.003). The setup errors in the SI, LR, AP directions of the enrolled 66 patients were (0.30±0.25) cm, (0.20±0.18) cm and (0.28±0.27) cm, respectively. Among them, the relative value of bladder volume in the AP direction was (0.73±0.37) in the setup error <0.3 cm group, which was statistically different from those in the setup error 0.3-0.5 cm and >0.5 cm groups (both P<0.05). Conclusion Under the bladder and bowel preparation before planning CT, the appropriate bladder and rectum volumes are in the range of 250-450 ml and <50 ml, which yields higher reproducibility and smaller setup error.
Li Ting,Guo Yujun,Yang Xin et al. Analysis of the rectum and bladder changes in prostate precise radiotherapy under the bowel and bladder preparation[J]. Chinese Journal of Radiation Oncology, 2023, 32(2): 124-130.
[1] Siegel RL, Miller KD, Fuchs HE, et al.Cancer statistics, 2022[J]. CA Cancer J Clin, 2022,72(1):7-33. DOI: 10.3322/caac.21708. [2] Liu X, Zhou M, Wang F, et al.Secular trend of cancer death and incidence in 29 cancer groups in China, 1990-2017: a joinpoint and age-period-cohort analysis[J]. Cancer Manag Res, 2020,12:6221-6238. DOI: 10.2147/CMAR.S247648. [3] Evans AJ.Treatment effects in prostate cancer[J]. Mod Pathol, 2018,31(S1):S110-121. DOI: 10.1038/modpathol. 2017.158. [4] Alongi F, de Crevoisier R, Corradini S, et al. Daily IGRT for prostate cancer: can we stop the train?[J]. Radiother Oncol, 2018,128(2):389-390. DOI: 10.1016/j.radonc. 2018.05.009. [5] Gill S, Thomas J, Fox C, et al.Acute toxicity in prostate cancer patients treated with and without image-guided radiotherapy[J]. Radiat Oncol, 2011,6:145. DOI: 10.1186/1748-717X-6-145. [6] Ariyaratne H, Chesham H, Pettingell J, et al.Image-guided radiotherapy for prostate cancer with cone beam CT: dosimetric effects of imaging frequency and PTV margin[J]. Radiother Oncol, 2016,121(1):103-108. DOI: 10.1016/j.radonc.2016.07.018. [7] Ghilezan M, Yan D, Liang J, et al.Online image-guided intensity-modulated radiotherapy for prostate cancer: how much improvement can we expect? A theoretical assessment of clinical benefits and potential dose escalation by improving precision and accuracy of radiation delivery[J]. Int J Radiat Oncol Biol Phys, 2004,60(5):1602-1610. DOI: 10.1016/j.ijrobp.2004.07.709. [8] Frank SJ, Dong L, Kudchadker RJ, et al.Quantification of prostate and seminal vesicle interfraction variation during IMRT[J]. Int J Radiat Oncol Biol Phys, 2008,71(3):813-820. DOI: 10.1016/j.ijrobp.2007.10.028. [9] Lebesque JV, Bruce AM, Kroes AP, et al.Variation in volumes, dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer[J]. Int J Radiat Oncol Biol Phys, 1995,33(5):1109-1119. DOI: 10.1016/0360-3016(95)00253-7. [10] O'Doherty UM, McNair HA, Norman AR, et al. Variability of bladder filling in patients receiving radical radiotherapy to the prostate[J]. Radiother Oncol, 2006,79(3):335-340. DOI: 10.1016/j.radonc.2006.05.007. [11] Pinkawa M, Asadpour B, Gagel B, et al.Prostate position variability and dose-volume histograms in radiotherapy for prostate cancer with full and empty bladder[J]. Int J Radiat Oncol Biol Phys, 2006,64(3):856-861. DOI: 10.1016/j.ijrobp.2005.08.016. [12] Stam MR, van Lin EN, van der Vight LP, et al. Bladder filling variation during radiation treatment of prostate cancer: can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling?[J]. Int J Radiat Oncol Biol Phys, 2006,65(2):371-377. DOI: 10.1016/j.ijrobp. 2005.12.039. [13] Song DY, Herfarth KK, Uhl M, et al.A multi-institutional clinical trial of rectal dose reduction via injected polyethylene-glycol hydrogel during intensity modulated radiation therapy for prostate cancer: analysis of dosimetric outcomes[J]. Int J Radiat Oncol Biol Phys, 2013,87(1):81-87. DOI: 10.1016/j.ijrobp.2012.12.019. [14] 钟嘉健, 丘敏敏, 邓永锦, 等. 两种膀胱充盈方式在宫颈癌术后调强放疗中的对比[J].中华肿瘤防治杂志,2021,28(12):944-948. DOI: 10.16073/j.cnki.cjcpt.2021.12.11. Zhong JJ, Qiu MM, Deng YJ, et al.Comparison of two methods of bladder filling in postoperative IMRT for cervical cancer[J].Chin J Cancer Prev Treat, 2021,28(12):944-948. DOI: 10.16073/j.cnki.cjcpt.2021.12.11. [15] Pearson D, Gill SK, Campbell N, et al.Dosimetric and volumetric changes in the rectum and bladder in patients receiving CBCT-guided prostate IMRT: analysis based on daily CBCT dose calculation[J]. J Appl Clin Med Phys, 2016,17(6):107-117. DOI: 10.1120/jacmp.v17i6.6207. [16] 黄思娟, 钟梓悦, 唐皓, 等. 肠道膀胱准备下不同固定方式对前列腺癌精准放疗影响[J].中华放射肿瘤学杂志,2022,31(08):716-721. DOI: 10.3760/cma. j. cn113030-2021 0802-00282. Huang SJ, Zhong ZY, Tang H, et al. Analysis of different fixation devices in precision radiotherapy for prostate cancer under bowel and bladder preparation protocol [J].Chin J Radiat Oncol, 2022,31(8):716-721. DOI:10.3760/cma. j. cn113030-20210802-00282. [17] Schaeffer E, Srinivas S, Antonarakis ES, et al.NCCN guidelines insights: prostate cancer, version 1.2021[J]. J Natl Compr Canc Netw, 2021,19(2):134-143. DOI: 10.6004/jnccn.2021.0008. [18] Pinkawa M, Siluschek J, Gagel B, et al.Influence of the initial rectal distension on posterior margins in primary and postoperative radiotherapy for prostate cancer[J]. Radiother Oncol, 2006,81(3):284-290. DOI: 10.1016/j.radonc.2006.10.028. [19] 中国医促会泌尿健康促进分会, 中国研究型医院学会泌尿外科学专业委员会. 前列腺癌放射治疗安全共识[J].现代泌尿外科杂志,2019,24(5):336-346. DOI: 10.3969/j.issn.1009-8291.2019.05.003 Urological Health Promotion Branch of China Medical Promotion Association, Urological Surgery Professional Committee of Chinese Research Hospital Society. Safety consensus of radiotherapy for prostate cancer[J]. J Modern Urol, 2019, 24(5): 336-346.DOI: 10.3969/j. issn. 1009-8291. 2019. 05.003. [20] Nakamura N, Shikama N, Takahashi O, et al.Variability in bladder volumes of full bladders in definitive radiotherapy for cases of localized prostate cancer[J]. Strahlenther Onkol, 2010,186(11):637-642. DOI: 10. 1007/s00066-010-2105-6. [21] Eminowicz G, Motlib J, Khan S, et al.Pelvic organ motion during radiotherapy for cervical cancer: understanding patterns and recommended patient preparation[J]. Clin Oncol (R Coll Radiol), 2016,28(9):e85-91. DOI: 10.1016/j.clon.2016.04.044. [22] Chen Z, Yang Z, Wang J, et al.Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy[J]. Radiat Oncol, 2016,11:103. DOI: 10.1186/s13014-016-0681-z. [23] Fujioka C, Ishii K, Yamanaga T, et al. Optimal bladder volume at treatment planning for prostate cancer patients receiving volumetric modulated arc therapy[J]. Pract Radiat Oncol, 2016,6(6):395-401. DOI:10.1016/j. prro.2016.05.007. [24] Roch M, Zapatero A, Castro P, et al.Dosimetric impact of rectum and bladder anatomy and intrafractional prostate motion on hypofractionated prostate radiation therapy[J]. Clin Transl Oncol, 2021,23(11):2293-2301. DOI: 10.1007/s12094-021-02628-3.