Breast board combined with a thermoplastic head mask immobilization can improve the reproducibility of the treatment setup for breast cancer patients receiving whole breast and supraclavicular nodal region irradiation
Ma Mingwei,Wang Shulian,Qin Shirui,Li Minghui,Zhang Jianghu,Tang Yu,Qi Shunan,Chen Siye, Ma Yuchao,Liu Xin,Li Yexiong
Department of Radiation Oncology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences ( CAMS ) and Peking Union Medical College ( PUMC),Beijing 100021,China
Abstract:Objective To quantify the setup errors measured with kV cone-beam CT (CBCT) using breast board with or without a thermoplastic head mask in breast cancer patients who received whole breast and supraclavicular nodal region irradiation. Clinical target volume (CTV) to planning target volume (PTV) in 3 directions were also calculated. Methods The study included thirty patient receiving both whole breast and supraclavicular nodal region irradiation on Elekta Versa HD linear accelerators (Elekta Oncology Systems,Crawley,UK) between June 2016 and January 2018.The setup error data were retrospectively analyzed. All the patients were immobilized in the supine position on a breast board system (Carbon fibre breast board,Civco,Iowa,USA) with both arms raised. Twenty of the patients added an extra thermoplastic head mask to immobilize the neck. A CBCT scan was taken before treatment at the first 3 to 5 fractions and then once every week. Registration with the planning CT was performed and adjusted to match the target volume of the supraclavicular nodal region and the cervical vertebra by experienced medical staff,the position of the arms and the breast were also considered. For all patients the couch shifts in left-right (x),superior-inferior (y),anterior-posterior (z) were recorded. Statistical analysis included two-tails significance tests (t-Student and Manne-Whitney test for means, χ2 test for variances).Population of the two groups was compared in terms of distribution of the mean shift (systematic error) and their standard deviations (random error).Van Herk′s setup margin defined as MPTV=2.5Σ+0.7δ was calculated in patients with or without mask immobilization. Results Altogether,56 images and 109 images were acquired in breast board only group and head mask group,respectively. Shifts of the breast board only group and the head mask group in x,y,z were 0.212±0.174 cm vs.0.272±0.242 cm (P=0.070);0.364±0.246 cm vs.0.242±0.171 cm (P=0.001);0.423±0.302 cm vs.0.364±0.269 cm (P=0.204).Proportion of the shift less than 5 mm in the breast board only group and the head mask group were 91.07% vs. 85.32%(P=0.294);67.86% vs.89.91%(P=0.001);67.86% vs.74.31%(P=0.381).The CTV to PTV margin in x,y,z were 0.645 cm,0.981 cm,1.317 cm in breast board only group and 0.873 cm,0.709 cm,0.961 cm in head mask group,respectively. Setup error in the x direction was significantly correlated with BMI (P=0.001). Conclusions For the alignment and immobilization of patients who received whole breast and supraclavicular nodal region irradiation,using a breast board in combination of a thermoplastic head mask may significantly help to reduce the shift variance in superior-inferior direction compared to using breast board only. The anterior-posterior error is relatively large,other immobilization device or patient alignment methods are needed to be further explored to improve the accuracy.
Ma Mingwei,Wang Shulian,Qin Shirui et al. Breast board combined with a thermoplastic head mask immobilization can improve the reproducibility of the treatment setup for breast cancer patients receiving whole breast and supraclavicular nodal region irradiation[J]. Chinese Journal of Radiation Oncology, 2019, 28(3): 217-221.
[1] Arriagada R,Le MG,Rochard F,et al. Conservative treatment versus mastectomy in early breast cancer:patterns of failure with 15 years of follow-up data. Institut Gustave-Roussy Breast Cancer Group[J].J Clin Oncol,1996,14(5):1558-1564.DOI:10.1200/jco.1996.14.5.1558. [2] Fisher B,Anderson S,Bryant J,et al. Twenty-year follow-up of a randomized trial comparing total mastectomy,lumpectomy,and lumpectomy plus irradiation for the treatment of invasive breast cancer[J].N Engl J Med,347(16),1233-1241.DOI:10.1056/NEJMoa022152. [3] Veronesi U,Cascinelli N,Mariani L,et al. Twenty-year follow-up of a randomized study comparing breast-conserving surgery with radical mastectomy for early breast cancer[J].N Engl J Med,2002,347(16):1227-32.DOI:10.1056/NEJMoa020989. [4] Clarke M,Collins R,Darby S,et al. Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival:an overview of the randomised trials[J].Lancet,2005,366(9503):2087-106.DOI:10.1016/s0140-6736(05)67887-7. [5] Darby S,McGale P,Correa C,et al. Effect of radiotherapy after breast-conserving surgery on 10-year recurrence and 15-year breast cancer death:meta-analysis of individual patient data for 10,801 women in 17 randomised trials[J].Lancet,2011,378(9804):1707-1716.DOI:10.1016/s0140-6736(11)61629-2. [6] Batumalai V,Phan P,Choong C,et al. Comparison of setup accuracy of three different image assessment methods for tangential breast radiotherapy[J].J Med Radiat Sci,2016,63(4):224-31.DOI:10.1002/jmrs.180. [7] Lin LL,Hertan L,Rengan R,et al. Effect of body mass index on magnitude of setup errors in patients treated with adjuvant radiotherapy for endometrial cancer with daily image guidance[J].Int J Radiat Oncol Biol Phys,2012,83(2):670-675.DOI:10.1016/j.ijrobp.2011.07.026. [8] Wong JR,Gao Z,Merrick S,et al. Potential for higher treatment failure in obese patients:correlation of elevated body mass index and increased daily prostate deviations from the radiation beam isocenters in an analysis of 1,465 computed tomographic images[J].Int J Radiat Oncol Biol Phys.2009,75(1):49-55.DOI:10.1016/j.ijrobp.2008.07.049. [9] Choi M,Fuller CD,Wang SJ,et al. Effect of body mass index on shifts in ultrasound-based image-guided intensity-modulated radiation therapy for abdominal malignancies[J].Radiother Oncol,2009,91(1):114-119. DOI:10.1016/j.radonc.2008.08.002. [10] van Herk M.Errors and margins in radiotherapy[J].Semin Radiat Oncol,2004,14(1):52-64.DOI:10.1053/j.semradonc.2003.10.003(2004). [11] 谢秋英,石锦平,张利文,等.个体化乳腺癌放疗体位固定技术改进方法研究[J].中华临床医师杂志(电子版),2014(7):1259-1262.DOI:10.3969/cma.j.issn.1674-0785.2014.07.013. Xie QY,Shi JP,Zhang LW,et al,An improved method of individualized breast cancer radiotherapy immobilization technology[J].Chin J Clinicians (Ele ed) 2014(7):1259-1262.DOI:10.3969/cma.j.issn.1674-0785.2014.07.013. [12] 王健仰,王淑莲,黄鹏,等.乳腺托架固定下全乳调强放疗摆位误差兆伏X线验证平片测定分析[J].中华放射肿瘤学杂志,2013,22(3):239-242.DOI:10.3760/cma.j.issn.1004-4221.2013.03.020. Wang JY,Wang SL,Huang P,et al. Assessment of setup error in orthogonal megavoltage X-ray film for whole breast radiation with breast bracket immobilized[J].Chin J Radiat Oncol,2013,22(3):239-242.DOI:10.3760/cma.j.issn.1004-4221.2013.03.020. [13] Penninkhof J,Quint S,Boer H,et al. Surgical clips for position verification and correction of non-rigid breast tissue in simultaneously integrated boost (SIB) treatments[J].Radiother Oncol,2009,90(1):110-115.DOI:10.1016/j.radonc.2008.10.009. [14] 刘翠翠,李建彬,范廷勇,等.锥形束CT引导自主呼吸控制保乳术后三维适形部分乳腺外照射术腔中银夹位移的研究[J].中华放射肿瘤学杂志,2008,17(1):43-46.DOI:10.3321/j.issn:1004-4221.2008.01.01. Liu CC,Li JB,Fan TY,et al,Cone-beam computed tomography guided study on silver dips displacement in breast cancer patients treated by three-dimensional conformal partial breast irradiation assisted by active breathing control after breast-conserving surgery[J].Chin J Radiat Oncol,2008,17(1):43-46.DOI:10.3321/j.issn:1004-4221.2008.01.01. [15] Gagel B,Demirel C,Kientopf A,et al. Active breathing control (ABC):determination and reduction of breathing-induced organ motion in the chest[J].Int J Radiat Oncol Biol Phys,2007,67(3):742-749.DOI:10.1016/j.ijrobp.2006.09.052. [16] Chopra S,Dinshaw KA,Kamble R,et al. Breast movement during normal and deep breathing,respiratory training and set up errors:implications for external beam partial breast irradiation[J].Br J Radiol,2006,79(945):766-773.DOI:10.1259/bjr/98024704. [17] Remouchamps VM,Letts N,Yan D,et al. Three-dimensional evaluation of intra-and interfraction immobilization of lung and chest wall using active breathing control:a reproducibility study with breast cancer patients[J].Int J Radiat Oncol Biol Phys,2003,57(4):968-978. [18] de Kruijf WJ,Martens RJ.Reducing patient posture variability using the predicted couch position[J].Med Dosim,2015,40(3):218-221.DOI:10.1016/S0360-3016(03)00710-7.