Department of Radiation Oncology,Cancer Hospital of Shantou University Medical College,Shantou 515031,China (Peng X,Huang BT,Lin ZX);Radiotherapy Center of Puning Overseas Chinese Hospital,Puning 515300,China (Liu ZH);Tumor Diagnosis and Treatment Center,The 188th Hospital of PLA,Chaozhou 521000,China (Yu XY);Department of Radiation Oncology,Shantou Central Hospital,Shantou 515031,China (Ke Q);Department of Oncology,Chaozhou People′s Hospital,Chaozhou 521011,China (Chen JB);Department of Radiation Oncology,Jieyang People′s Hospital,Jieyang 522000,China (Ouyang D);Department of Radiation Oncology,Meizhou People′s Hospital,Meizhou 514032,China (Ma TB);Department of Oncology,Haifeng Pengpai Memorial Hospital,Haifeng 516400,China (Gao DS);Department of Radiation Oncology,Sun Yat-sen University Cancer Center,State Key Laboratory of Oncology in South China,Collaborative Innovation Center of Cancer Medicine,Guangdong Provincial Clinic Quality Assurance Center for Radiotherapy,Guangzhou 510060,China (Deng XW)
Abstract: Objective To investigate the physics technique and quality assurance (QA) during radiotherapy in the institutions from the East Guangdong province, aiming to provide reference for the construction of radiotherapy discipline and rational allocation of resources in the primary hospitals from the eastern Guangdong province. Methods From March 15 to May 20, 2016, the general conditions, radiotherapy equipment, available technique and quality assurance (QA) in the medical institutions from eastern Guangdong were investigated and analyzed by online combined with on-spot surgery. Results There were 8 institutions which provided radiotherapy with 966 ward beds, a daily capacity of 632 patients and 222 radiotherapy practitioners. Radiotherapy equipment included 12 linear accelerators, 5 after-loading devices, 1γ-knife, 8 CT simulators and 9 radiotherapy planning systems. Five institutions performed IMRT/VMAT, IGRT and ART. Dose verification was performed before precision radiotherapy delivery in all institutions except for 1 center. QA procedures were missing for the linear accelerators, CT simulators and after-loading devices. Short-term advanced studies and hand-by-hand teaching were the main approaches for staff professional training. Conclusions The resource allocation for radiotherapy in the medical centers from the eastern Guangdong province is scarce. The technique and QC levels greatly differ among different institutions. Standard QA protocols are urgently to be established and implemented. Extensive attentions should be paid to the the professional training for technicians.
Peng Xun,Huang Baotian,Liu Zhihua et al. Investigation and research of physics technique and quality assurance for radiotherapy in east guangdong province[J]. Chinese Journal of Radiation Oncology, 2018, 27(4): 343-347.
[1] 郞锦义,王培,吴大可,等.2015年中国大陆放疗基本情况调查研究[J].中华放射肿瘤学杂志,2016,25(6):541-545.DOI:10.3760/cma.j.issn.1001-4221.2016.06.001. Lang JY,Wang P,Wu DK,et al. An investigation of the basic situation of radiotherapy in mainland China in 2015[J].Chin J Radiat Oncol,2016,25(6):541-545.DOI:10.3760/cma.j.issn.1001-4221.2016.06.001. [2] Chen WQ,Zheng RS,Baade PD,et al. Cancer statistics in China,2015[J].CA Cancer J Clin,2016,66(2):115-132.DOI:10.3322/caac.21338. [3] IAEA. Setting up a radiotherapy programme:clinical,medical physics,radiation protection and safety aspects[M].Wien:IAEA,2008. [4] 林珠,黄宝添,彭逊.医用直线加速器的质量保证与质量控制[J].齐齐哈尔医学院学报,2015,36(9):1344-1346. Lin Z,Huang BT,Peng X.Quality assurance and quality control of medical linear accelerator[J].J Qiqihar Univ Med,2015,36(9):1344-1346. [5] 王颖,于金明.放疗中质量保证和质量控制及其重要性[J].重庆医学,2015,44(34):4753-4758.DOI:10.3969/j.issn.1671-8348.2015.34.001. Wang Y,Yu JM.Quality assurance and quality control in radiotherapy and its importance[J].Chongqing Med,2015,44(34):4753-4758.DOI:10.3969/j.issn.1671-8348.2015.34.001. [6] 张会敏,赵新春,陈掌凡,等.广西医用电子加速器质量控制现状及控制策略[J].职业与健康,2015,31(18):2558-2560.DOI:10.13329/j.cnki.zyyjk.2015.0884. Zhang HM,Zhao XC,Chen ZF,et al. Quality control situation and quality control strategy of medical electron accelerator in Guangxi Province[J].Occup Health,2015,31(18):2558-2560.DOI:10.13329/j.cnki.zyyjk.2015.0884. [7] 马永忠,万玲,冯泽臣,等.北京市放疗设备质量控制检测与分析[J].首都公共卫生,2013,7(4):151-154.DOI:10.3969/j.issn.1673-7830.2013.04.003. Ma YZ,Wan L,Feng ZC,et al. Quality control testing and analysis on the radiotherapy devices in Beijing[J].Cap J Public Health,2013,7(4):151-154.DOI:10.3969/j.issn.1673-7830.2013.04.003. [8] 胡世杰,黄伟旭,杨浩贤,等.广东省医用直线加速器防护性能检测结果分析[J].中国辐射卫生,2005,14(4):280-281.DOI:10.13491/j.cnki.issn.1004-714x.2005.04.029. Hu SJ,Huang WX,Yang HX,et al. Analysis of the protection status of medical accelerator in Guangdong[J].Chin J Radiol Health,2005,14(4):280-281.DOI:10.13491/j.cnki.issn.1004-714x.2005.04.029. [9] 杨超凤,邓烨,杨海明.放射肿瘤物理师规范化岗前培训的探索与实践[J].中国继续医学教育,2015,7(30):1-2.DOI:10.3969/j.issn.1674-9308.2015.30.001. Yang CF,Deng Y,Yang HM.Exploration and practice of pre-job training in radiation oncology physics division standard[J].China Continu Med Educat,2015,7(30):1-2.DOI:10.3969/j.issn.1674-9308.2015.30.001. [10] 孙显松,王欣海,管秋,等.放疗技师规范化培训的探索与实践[J].协和医学杂志,2013,4(4):464-466.DOI:10.3969/j.issn.1674-9081.2013.04.026. Sun XS,Wang XH,Guan Q.Exploration and Practice of Normalization Training for Radiotherapy Technicians[J] Med J Pek Uni Med Coll Hosp,2013,4(4):464-466.DOI:10.3969/j.issn.1674-9081.2013.04.026.