Abstract:Objective To study three contouring approaches of the bowel and evaluate the bowel dose volume with cervical cancer patient. Methods Twelve patients were selected,prescribed dose 45 Gy/25f. For each patient we contoured the bowel according to three different definitions:bowel loops,bowel bag and peritoneal space. Then we generated three rival plans each considering a different bowel definition and to evaluate dose differences of the HI,CI of PTV and Dmax,Dmean,V5-V45 of bowel loops with paired t-test. Results Comparison between BL and BB plan,Dmax,HI and CI of PTV,V5-V45 of bowel loops were not significantly different (P=0.171,0.076,0.192,P=0.315-0.855),Dmean of PTV and Dmax of bowel loops had difference (P=0.017,0.038).Comparison between BL and PS plan,Dmax, Dmean,HI and CI of PTV and Dmax of bowel loops had differences (P=0.033,0.044,0.046,0.041,0.013),V5-V45 of bowel loops were not significantly different (P=0.416-0.977).If the bowel loops V40≤15%,and bowel bag and peritoneal space V40≤20%. Conclusions All definitions provided a very similar dose volume of bowel loops. Taking into account HI and CI of PTV and max dose of bowel loops,BB seems better than PS.
Sun Yanze,Zhou Gang,Qian Jianjun et al. The comparison of three bowel delineation strategies in the radiation therapy of cervical cancer[J]. Chinese Journal of Radiation Oncology, 2016, 25(1): 67-70.
[1]Kavanagh BD,Pan CC,Dawson LA,et al. Radiation dose-volume effects in the stomach and small bowel[J].Int J Radiat Oncol Biol Phys,2010,76(3 Suppl):S101-S107.DOI:10.1016/j.ijrobp.2009.05.071. [2]Banerjee R,Chakraborty S,Nygren I,et al. Small bowel dose parameters predicting grade ≥3 acute toxicity in rectal cancer patients treated with neoadjuvant chemoradiation:an independent validation study comparing peritoneal space versus small bowel loop contouring techniques[J].Int J Radiat Oncol Biol Phys,2013,85(5):1225-1231.DOI:10.1016/j.ijrobp.2012.09.036. [3]郭玉燕,张纬建.直肠癌术前放疗小肠评价指标的研究进展[J].福建医药杂志,2013,35(3):154-156.DOI:10.3969/j.issn.1002-2600.2013.03.069. Guo YY,Zhang WJ.Research progress in evaluation indexes of small intestine of preoperative radiotherapy in rectal cancer[J].Fujian Med J,2013,35(3):154-156.DOI:10.3969/j.issn.1002-2600.2013.03.069. [4]Gay HA,Barthold HJ,O’Meara E,et al. Pelvic normal tissue contouring guidelines for radiation therapy:a Radiation Therapy Oncology Group consensus panel atlas[J].Int J Radiat Oncol Biol Phys,2012,83(3):e353-e362.DOI:10.1016/j.ijrobp.2012.01.023. [5]Hysing LB,Kvinnsland Y,Lord H,et al. Planning organ at risk volume margins for organ motion of the intestine[J].Radiother Oncol,2006,80(3):349-354.DOI:10.1016/j.radonc.2006.07.039. [6]Kvinnsland Y,Muren LP.The impact of organ motion on intestine doses and complication probabilities in radiotherapy of bladder cancer[J].Radiother Oncol,2005,76(1):43-47.DOI:10.1016/j.radonc.2005.06.007. [7]Dominello MM,Nalichowski A,Paximadis P,et al. Limitations of the bowel bag contouring technique in the definitive treatment of cervical cancer[J].Pract Radiat Oncol,2014,4(1):e15-e20.DOI:10.1016/j.prro.2013.04.003. [8]Sanguineti G,Little M,Endres EJ,et al. Comparison of three strategies to delineate the bowel for whole pelvis IMRT of prostate cancer[J].Radiother Oncol,2008,88(1):95-101.DOI:10.1016/j.radonc.2008.01.015. [9]Dolezel M,Odrazka K,Vanasek J,et al. MRI-based pre-planning in patients with cervical cancer treated with three-dimensional brachytherapy[J].Br J Radiol,2011,84(1005):850-856.DOI:10.1259/bjr/75446993. [10]Wiesendanger-Wittmer EM,Sijtsema NM,Muijs CT,et al. Systematic review of the role of a belly board device in radiotherapy delivery in patients with pelvic malignancies[J].Radiother Oncol,2012,102(3):325-334.DOI:10.1016/j.radonc.2012.02.004.