Abstract:Objective To study the impacts of bladder filling status on the dosimetric parameters of the target volume and organs at risk (OAR) in intensity-modulated radiotherapy (IMRT) for prostate cancer. Methods Ten localized prostate cancer patients without serious complications treated with IMRT were selected for this study. These patients underwent CT scans of the whole pelvic cavity three times in different bladder filling status (empty and injected with 150 ml and 300 ml of normal saline) to obtain three series of pelvic CT images. The three sets of CT images were transferred to the treatment planning system. The target volume and OAR such as the rectum, bladder, and femoral heads were contoured by the same doctor. The treatment planning was performed and optimized by the physicist. The dosimetric parameters of the target volume and OAR in three bladder filling status were subjected to analysis by paired t-test. Results If the bladder filling status was consistent in orientation and radiation, the bladder filling status was not associated with the dosimetric parameters of the target volume and femoral heads (P=0.077-0.998;P=0.219-0.969);it had significant impacts on the dosimetric parameters of the bladder (P=0.000-0.562) and some dosimetric parameters of the rectum (P=0.000-0.645), and bladder filling was favorable for the protection of the bladder and rectum. If the bladder filling status was not consistent in orientation and actual radiation, the calculated planning target volume, the dosimetric parameters of the bladder, and some dosimetric parameters of the rectum were different from those in actual treatment (P=0.000-0.913). Conclusions For the prostate cancer patients treated with IMRT, it is recommended to keep the bladder well and consistently filled.
Zhang Liang,Ju Yongjian,Wang Gaoren et al. Impacts of bladder filling status on dosimetric parameters of target volume and OAR in intensity-modulated radiotherapy for prostate cancer[J]. Chinese Journal of Radiation Oncology, 2014, 23(5): 382-385.
[1] Hynds S, McGarry CK, Mitchell DM, et al. Assessing the daily consistency of bladder filling using an ultrasonic bladder scan device in men receiving radical conformal radiotherapy for prostate cancer[J]. Br J Radiol,2011,84:813-818. [2] Jain S, Loblaw DA, Morton GC, et al. The effect of radiation technique and bladder filling on the acute toxicity of pelvic radiotherapy for localized high risk prostate cancer[J]. Radiother Oncol,2012,105:193-197. [3] Moiseenko V, Liu M, Kristensen S, et al. Effect of bladder filling on doses to prostate and organs at risk:a treatment planning study[J]. J Appl Clin Med Phys,2006,8:55-68. [4] Tsai CL, Wu JK, Wang CW, et al. Using cone-beam computed tomography to evaluate the impact of bladder filling status on target position in prostate radiotherapy[J]. Strahlenther Onkol,2009,185:588-595. [5] Adamson J, Wu Q. Inferences about prostate intrafraction motion from pre-and posttreatment volumetric imaging[J]. Int J Radiat Oncol Biol Phys,2009,75:260-267. [6] 刘跃平,刘新帆,李晔雄,等.膀胱充盈状态对前列腺癌三维适形放疗靶区和重要器官的影响[J].中华放射肿瘤学杂志,2007,16:48-51. [7] Lebesque JV, Bruce AM, Kroes AP, et a1.Variation in volumes,dose-volume histograms, and estimated normal tissue complication probabilities of rectum and bladder during conformal radiotherapy of T3 prostate cancer[J].Int J Radiat Oncol Biol Phys,1995,33:1109-1119. [8] Buchali A, Koswig S, Dinges S, et a1.Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecologial cancer[J].Radiother Oncol,1999,52:29-34. [9] Pinkawa M, Siluschek J, Gagel B, et al. Postoperative radiotherapy for prostate cancer:evaluation of target motion and treatment techniques (intensity-modulated versus conformal radiotherapy)[J]. Strahlenther Onkol,2007,183:23-29. [10] Diot Q, Olsen C, Kavanagh B, et al. Dosimetric effect of online image-guided anatomical interventions for postprostatectomy cancer patients[J]. Int J Radiat Oncol Biol Phys,2011,79:623-632. [11] Stam MR, van Lin EN, van der Vight LP, et al. Bladder filling variation during radiation treatment of prostate cancer:can the use of a bladder ultrasound scanner and biofeedback optimize bladder filling?[J]. Int J Radiat Oncol Biol Phys,2006,65:371-377.