Investigation of 8 MV X-rays energy spectrum structure of medical linear accelerator
BAI Yan-ling*, XIAO Xue-fu, SHAO Wen-cheng
*Department of Radiation Physics, Third Hospital of Harbin Medical University, Harbin 150081, China Corresponding author:XIAO Xue-fu, Department of Radiation Metrology, China Institute of Atomic Energy, Beijing 102413,China
Abstract:Objective To study the spectrum structure of X-ray and simplify the description method of it. Methods By the general program of Monte Carlo Geant4 to study X-ray spectrum structure and angular distribution of X-ray energy spectrum. Results The results of percentage depth doses and profile curves at different depths of any radiation fields in water phantom calculated by Monte Carlo Geant4 were consistent with the measurements. Conclusions In radiotherapy, X-ray with same nominal energy have very similar dosimetry characteristics, this indicates they have very similar energy spectrum and angular distribution of spectrum, the differences of dosimetric details reflect the different details of the X-ray spectrum structure and angular distribution of X-ray energy spectrum. These studies have very important significances to rapidly build precise virtual source modeling for Monte Carlo calculation based on dose curves measurements in water phantom.
BAI Yan-ling*,XIAO Xue-fu,SHAO Wen-cheng. Investigation of 8 MV X-rays energy spectrum structure of medical linear accelerator[J]. Chinese Journal of Radiation Oncology, 2012, 21(2): 181-184.
[1] Chetty IJ, Curran B, Cygler JE, et al. The AAPM task group report No.105:issues associated with clinical implementation of Monte Carlo-based external beam treatment planning. Med Phys,2007,34:4818-4853. [2] Reynaert N, van der Marck SC, Schaart DR, et al. Monte Carlo treatment planning for photon and electron beams. Radiat Phys Chem,2007,76:643-686. [3] 张松柏,黄斐增,韩树奎,等. 6 MV医用电子直线加速器轫致辐射谱研究.原子能科学技术,2003,37:226-229. [4] Juste B, Miro R, Campayo JM, et al. Photon spectra calculation for an Elekta linac beam using experimental scatter measurements and Monte Carlo techniques. Conf Proc IEEE Eng Med Biol Soc,2008,2008:3289-3292. [5] Fippel M, Haryanto F, Dohm O, et al. A virtual photon energy fluence model for Monte Carlo dose calculation. Med Phys,2003,30:301-311. [6] Gardner J, Siebers J, Kawrakow I. Dose calculation validation of VMC++ for photon beams. Med Phys,2007,34:1809-1818. [7] Cygler JE, Daskalov GM, Chan GH. Evalution of the first commercial Monte Carlo beam treatment planning. Med Phys,2004,31:142-153.