Simulation of the discrepancy in 4DCT-based cumulative dose using digital phantoms
Liu Gang,Yang Zhiyong,Liang Zhiwen,Yang Jing, Nie Xin,Cao Ting,Quan Hong,Zhang Jun,Li Qin
Center of Radiotherapy Oncology,Union Hospital,Tongji Medical Colloge,Huazhong University of Science and Technology,Wuhan 430023,China (Liu G,Yang ZY,Liang ZW,Yang J,Nie X,Cao T,Li Q);School of Physics and Technology,Wuhan University,Wuhan 430072,China (Quan H);Department of Radiation Oncology,Zhongnan Hospital,Wuhan University,Wuhan 430071,China (Zhang J)
Abstract Objective To conduct a computer simulation to evaluate the discrepancy between the cumulative doses calculated by four-dimensional computed tomography (4DCT) images and 4DCT scans (for real-time respiratory motions) due to the patient’s irregular breathing. Methods A series of digital phantoms were generated from a patient’s 4DCT images to simulate 4DCT images and 4DCT scans (for real-time respiratory motions) resulting from various irregular breathing curves. A six-field intensity-modulated radiotherapy plan was generated. Two cumulative doses in the target were calculated. The first one, named Dall, was calculated by tracking the point displacements in the target manifested on the 4DCT images;the second one, named D4D, was calculated based on the point displacements along the whole breathing motion during 4DCT scanning. Dose discrepancy betweenD4D and Dallwas calculated to evaluate the correlation between breathing pattern and dose discrepancy in the target. Results The dose discrepancy in the target was correlated with mean motion excursion and the standard deviation of motion excursion.ΔDmin(ΔD99)in the target increased from 2.39%(2.04%) to 11.91%(5.24%) as the mean motion excursion increased from 5 mm to 15 mm, and increased from 5.93%(2.15%) to 14.65%(5.01%) as the standard deviation of motion excursion increased from 15% to 45% of the mean motion excursion. When the mean period increased from 3 s to 5 s or the standard deviation of period increased from 10% to 40% of the mean period,ΔDmin(ΔD99)in the target was greater than 6.0%(2.0%), but less than 9.0%(3.0%). When the target diameter was 2 cm, 3 cm, and 4 cm,ΔDmin(ΔD99)in the target was 11.88%(5.50%), 6.91%(2.42%), and 7.53%(3.62%), respectively. Conclusions There is a large discrepancy between the cumulative doses calculated using 4DCT images and 4DCT scans (for real-time respiratory motions) when the patient has irregular breathing. This dose discrepancy depends on mean motion excursion and the standard deviation of motion excursion, but has little relationship with mean period, the standard deviation of period, and tumor volume.
Liu Gang,Yang Zhiyong,Liang Zhiwen et al. Simulation of the discrepancy in 4DCT-based cumulative dose using digital phantoms[J]. Chinese Journal of Radiation Oncology, 2017, 26(7): 790-794.
Liu Gang,Yang Zhiyong,Liang Zhiwen et al. Simulation of the discrepancy in 4DCT-based cumulative dose using digital phantoms[J]. Chinese Journal of Radiation Oncology, 2017, 26(7): 790-794.
[1] Ford EC,Mageras GS,Yorke E,et al. Respiration-correlated spiral CT:a method of measuring respiratory-induced anatomic motion for radiation treatment planning[J].Med Phys,2003,30(1):88-97.DOI:10.1118/1.1531177. [2] Low DA,Nystrom M,Kalinin E,et al. A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing[J].Med Phys,2003,30(6):1254-1263.DOI:10.1118/1.1576230. [3] Castillo SJ,Castillo R,Balter P,et al. Assessment of a quantitative metric for 4D CT artifact evaluation by observer consensus[J].J Appl Clin Med Phys,2014,15(3):190-201.DOI:10.1120/jacmp.v15i3.4718. [4] Guckenberger M,Wilbert J,Meyer J,et al. Is a single respiratory correlated 4D-CT study sufficient for evaluation of breathing motion?[J].Int J Radiat Oncol Biol Phys,2007,67(5):1352-1359.DOI:10.1016/j.ijrobp.2006.11.025. [5] Liao Y,Turian J,Templeton A,et al. SU-E-J-35:using CBCT as the alternative method of assessing ITV volume[J].Med Phys,2015,42(6):3271.DOI:10.1118/1.4924122. [6] Suryanto A,Herlambang K,Rachmatullah P.Comparison of tumor density by CT scan based on histologic type in lung cancer patients[J].Acta Med Indones,2005,37(4):195-198. [7] Glide-Hurst CK,Hugo GD,Liang J,et al. A simplified method of four-dimensional dose accumulation using the mean patient density representation[J].Med Phys,2008,35(12):5269-5277.DOI:10.1118/1.3002304. [8] Wink NM,Panknin C,Solberg TD.Phase versus amplitude sorting of 4D-CT data[J].J Appl Clin Med Phys,2006,7(1):77-85.DOI:10.1120/jacmp.v7i1.2198. [9] Koybasi O,Mishra P,St. James S,et al. Simulation of dosimetric consequences of 4D-CT-based motion margin estimation for proton radiotherapy using patient tumor motion data[J].Phys Med Biol,2014,59(4):853-867.DOI:10.1088/0031-9155/59/4/853. [10] Blomgren H,Lax I,N slund I,et al. Stereotactic high dose fraction radiation therapy of extracranial tumors using an accelerator:clinical experience of the first thirty-one patients[J].Acta Oncol,1995,34(6):861-870.DOI:10.3109/02841869509127197.