AbstractObjective To establish a novel Monte Carlo simulation method for reconstruction of medical accelerator model and X-ray energy spectrum based on IAEA Varian 6 MV X-ray phase-space file and photon energy spectrum of the target accelerator. Methods The verified 6 MV X-ray phase-space files were preprocessed to elevate the energy of each particle. Particles were saved in different Phase-Space-Let (PSL) files according to their position and energy, yielding an initial photon energy spectrum for Monte Carlo simulation of accelerator under an initial target energy. The initial photon energy spectrum was fit to a photon energy spectrum of an accelerator (Elekta Precise 10 MV X-ray accelerator) under an unknown target energy to yield a fitting coefficient, which was the weight of each PSL. Finally, an accelerator model under an unknown target energy was reconstructed using the initial PSL files and the weight information. The percentage depth dose (PDD) distribution was calculated in different square open fields. The effectiveness of this method was verified using one dimensional gamma passing rate. Results The peak position and overall distribution of the reconstructed 10 MV photon energy spectrum were in accordance with those of the verified 10 MV photon energy spectrum. The PDD calculated from the reconstructed 10 MV accelerator model agreed well with the measured PDD. The one-dimensional gamma passing rate was above 96%(1%/1 mm, threshold=0%). Conclusions The Monte Carlo reconstruction method proposed in this study is reliable, accurate, and effective.
Fund:Major Project of Shanghai Municipal Health and Family Planning Commission (201540032)
Corresponding Authors:
Yao Hui,Email:yaohuish@126.com
E-mail: yaohuish@126.com
Cite this article:
Wang Yun,Yao Hui,Wang Jiehua et al. A Monte Carlo simulation method for reconstruction of accelerator based on verified 6 MV X-ray phase-space and energy spectrum information [J]. Chinese Journal of Radiation Oncology, 2016, 25(8): 847-850.
Wang Yun,Yao Hui,Wang Jiehua et al. A Monte Carlo simulation method for reconstruction of accelerator based on verified 6 MV X-ray phase-space and energy spectrum information [J]. Chinese Journal of Radiation Oncology, 2016, 25(8): 847-850.
[1] Townson RW,Jia X,Tian Z,et al. GPU-based Monte-Carlo radiotherapy dose calculation using phase-space sources[J].Phys Med Biol,2013,58(12):4341-4356.DOI:10.1088/0031-9155/58/12/4341 [2] Tian Z,Graves YJ,Jia X,et al. Automatic commissioning of a GPU-based Monte Carlo radiation dose calculation code for photon radiotherapy[J].Phys Med Biol,2014,59(21):6467-6486.DOI:10.1088/0031-9155/59/21/6467 [3] Jia X,Gu XJ,Grave YJ,et al. GPU-based fast Monte Carlo simulation for radiotherapy dose calculation[J].Phys Med Biol,2011,56(22):7017-7031.DOI:10.1088/0031-9155/56/22/002 [4] 陈朝斌,黄群英,吴宜灿,等.蒙特卡罗方法在放疗计划中的应用[J].核技术,2006,29(1):22-28.DOI:10.3321/j.issn:0253-3219.2006.01.006 Chen CB,Huang QY,Wu YC,et al. Application of Monte Carlo techniques in radiation treatment planning[J].Nucl Tech,2006,29(1):22-28.DOI:10.3321/j.issn:0253-3219.2006.01.006 [5] ICRU. Prescribing,recording,and reporting photon beam therapy[R].Bethesda:Commission on Radiation and Measurement,1993 [6] 时颖华,周凌宏,刘迎军,等.6 MV医用电子直线加速器的蒙特卡罗模拟[J].中华放射医学与防护杂志,2011,31(2):220-224.DOI:10.3760/cma.j.issn.0254-5098.2011.02.028 Shi YH,Zhou LH,Liu YJ,et al. Monte Carlo simulation of 6 MV medical electron linear accelerator[J].Chin J Radiol Med Protect,2011,31(2):220-224.DOI:10.3760/cma.j.issn.0254-5098.2011.02.028 [7] 傅玉川.蒙特卡罗模拟在医用直线加速器治疗头设计中的作用[J].医疗装备,2006(10):49-51.Fu YCH.The role of Monte Carlo simulation in the design of medical linear accelerator[J].Med Equip,2006(10):49-51 [8] 周凌宏,金浩宇,陈超敏.基于蒙特卡罗模拟的快速剂量计算方法研究[J].仪器仪表学报,2007,28(4):699-702.DOI:10.3321/j.issn:0254-3087.2007.04.023 Zhou LH,Jin HY,Chen CM.Fast dose calculation model based on Monte Carlo simulation[J].Chin J Sci Inst,2007,28(4):699-702.DOI:10.3321/j.issn:0254-3087.2007.04.023