Development and evaluation of whole breast irradiation with volumetric modulated arc therapy-based hybrid intensity-modulated radiotherapy after breast conserving surgery for breast cancer
Department of Radiation Oncology,National Cancer Center/Cancer Hospital,Chinese Academy of Medical Science,Peking Union Medical College,Beiijng 100021,China
Abstract Objective To develop whole breast irradiation with volumetric-modulated arc therapy (VMAT)-based hybrid intensity-modulated radiotherapy (IMRT) after breast conserving surgery for breast cancer, and to evaluate its value in clinical application. Methods Ten patients with breast cancer undergoing breast conserving surgery were enrolled. Two radiotherapy plans were designed based on hybrid fixed-beam IMRT/IMRT technique and hybrid VMAT/IMRT technique, respectively. One group received whole breast irradiation with a prescribed dose of 50 Gy in 25 fractions. The other group received whole breast irradiation with a prescribed dose of 50 Gy in 25 fractions, as well as simultaneous integrated boost to the tumor bed with 60 Gy in 25 fractions. The dosimetric parameters and delivery efficiency were compared between the two plans using paired t test. Results For patients treated with whole breast irradiation alone, there were no significant differences in conformity index and homogeneity index of target volume between the two plans (P=0.866,0.056);however, compared with the hybrid fixed-beam IMRT/IMRT technique, the hybrid VMAT/IMRT technique significantly increased the doses to organs at risk (OARs) and the number of monitor units (MUs) in the intensity-modulated field (P=0.000-0.050,P=0.002). For patients treated with whole breast irradiation with a simultaneous integrated boost to the tumor bed;however, the hybrid VMAT/IMRT technique significantly reduced the doses to the lung and spinal cord, number of MUs in intensity-modulated field, and delivery time compared with the hybrid fixed-beam IMRT/IMRT technique (P=0.004,0.001,0.000,0.000). Conclusions For patients treated with whole breast irradiation with a simultaneous integrated boost to the tumor bed, the hybrid VMAT/IMRT technique is highly promising for clinical application due to better OAR sparing and higher delivery efficiency.
Corresponding Authors:
Dai Jianrong,Email:Dai_jianrong@163.com
Cite this article:
Tian Yuan,Ma Pan,Men kuo et al. Development and evaluation of whole breast irradiation with volumetric modulated arc therapy-based hybrid intensity-modulated radiotherapy after breast conserving surgery for breast cancer[J]. Chinese Journal of Radiation Oncology, 2016, 25(7): 728-732.
Tian Yuan,Ma Pan,Men kuo et al. Development and evaluation of whole breast irradiation with volumetric modulated arc therapy-based hybrid intensity-modulated radiotherapy after breast conserving surgery for breast cancer[J]. Chinese Journal of Radiation Oncology, 2016, 25(7): 728-732.
[1]郑莹,吴春晓,张敏璐.乳腺癌在中国的流行状况和疾病特征[J].中国癌症杂志,2013,23(8):561-569.DOI:10.3969/j.issn.1007-3969.2013.08.001 Zheng Y,Wu CX,Zhang ML.The epidemic and characteristics of female breast ancer in China[J].China Oncol,2013,23(8):561-569.DOI:10.3969/j.issn.1007-3969.2013.08.001 [2]Thomsen MS,Harrov U,Fledelius W,et al. Inter-and intra-fraction geometric errors in daily image-guided radiotherapy of free-breathing breast cancer patients measured with continuous portal imaging[J].Acta Oncol,2014,53(6):802-808.DOI:10.3109/0284186X.2014.905700 [3]Mayo C,Lo YC,Fitzgerald TJ,et al. Forward-planned,multiple-segment,tangential fields with concomitant boost in the treatment of breast cancer[J].Med Dosim,2004,29(4):265-270.DOI:10.1016/j.meddos.2003.12.003 [4]马攀,章众,陈辛元,等.乳腺锁骨上淋巴区调强放疗的计划设计方法[A]//中华医学会放射肿瘤治疗分会. 中华医学会放射肿瘤治疗分会六届二次暨中国抗癌协会肿瘤放疗专业委员会二届二次学术会议论文集[C].济南:中华医学会,中国抗癌协会,2009:491-492 Ma P,Zhang ZH,Chen XY,et al. The planning design method of breast supraclavicular lymphatic area with Intensity modulated radiation therapy[A]//Radiation oncology therapy branch of Chinese medical association. The proceedings of radiation oncology therapy of Chinese medical association branch of the six secondary radiation oncology and Chinese anti-cancer association professional committee of the second session of the second academic conference[C].Jinan:Chinese medical association, Chinese anti-cancer association,2009:491-492 [5]Stanley J,Dunscombe P,Lau H,et al. The effect of contouring variability on dosimetric parameters for brain metastases treated with stereotactic radiosurgery[J].Int J Radiat Oncol Biol Phys,2013,87(5):924-931.DOI:10.1016/j.ijrobp.2013.09.013 [6]Pasquier D,Cavillon F,Lacornerie T,et al. A dosimetric comparison of tomotherapy and volumetric modulated arc therapy in the treatment of high-risk prostate cancer with pelvic nodal radiation therapy[J].Int J Radiat Oncol Biol Phys,2013,85(2):549-554.DOI:10.1016/j.ijrobp.2012.03.046 [7]姜庆丰,柏森,傅玉川,等.容积旋转调强技术在乳腺癌根治术后放射治疗中的应用[J].川北医学院学报,2012,27(2):102-108.DOI:10.3969/j.issn.1005-3697.2012.02.003 Jiang QF,Bai S,Fu YC,et al. Feasibility of volumetric modulated arc therapy applied to breast cancer radiotherapy after radical surgery[J].J North Sichuan Med Coll,2012,27(2):102-108.DOI:10.3969/j.issn.1005-3697.2012.02.003 [8]李丹明,王黎,孙新臣,等.2种容积旋转调强技术在乳腺癌改良根治术后放疗剂量学中的应用比较[J].实用临床医药杂志,2014,18(16):70-74.DOI:10.7619/jcmp.201416020 Li DM,Wang L,Sun XC,et al. Dosimetric comparison between two volumetric modulated photon arc therapies for patients with breast cancer mastecomy[J].J Clin Med Prac,2014,18(16):70-74.DOI:10.7619/jcmp.201416020.