AbstractObjective To investigate the role of self-made auxiliary device in pelvic tumor radiotherapy with phantom immobilization using Varian cone-beam CT (CBCT). Methods A total of 50 patients with pelvic tumor were enrolled and randomly divided into study group and control group according to the order of enrollment. The patients in the study group were immobilized with thermoplastic phantom and self-made auxiliary device, and those in the control group were immobilized with thermoplastic phantom. CBCT scan and online matching were regularly performed before radiotherapy to obtain the setup errors of the left-right (x), cranial-caudal (y), and anterior-posterior (z) directions. The independent-samples t-test was used for comparison between groups. Results The set-up errors in the x-, y-, and z-directions in the study group were 1.56±1.00 mm, 1.60±1.29 mm, and 1.36±1.00 mm, respectively, and those in the control group were 1.76±1.33 mm, 2.76±1.69 mm, and 1.92±0.91 mm, respectively (P=0.551, 0.009, and 0.043). Conclusions Self-made auxiliary device helps to eliminate the errors in the cranial-caudal direction and solve the problem of involuntary activities of the lower limbs.
Corresponding Authors:
Shi Mei,Email:mshi82@fmmuedu.cn
Cite this article:
Bai Fei,Shi Mei,Li Jie et al. Role of self-made auxiliary device in precise radiotherapy for pelvic tumor[J]. Chinese Journal of Radiation Oncology, 2016, 25(6): 615-617.
Bai Fei,Shi Mei,Li Jie et al. Role of self-made auxiliary device in precise radiotherapy for pelvic tumor[J]. Chinese Journal of Radiation Oncology, 2016, 25(6): 615-617.
[1] 杨定字.放疗技术员的工作职责[A]//胡逸民,杨定宇.肿瘤放疗技术[M].北京:北京医科大学中国协和医科大学联合出版社,1999:14. Yang DY.Job responsibilities of radiotherapy technician[A]//Hu YM,Yang DY.Tumor radiotherapy technique[M].Beijing:United Press of Peking Union Medical College, Beijing Medical University,1999:14. [2] Kang H,Lovelock DM,Yorke ED,et al. Accurate positioning for head and neck cancer patients using 2D and 3D image guidance[J].J Appl Clin Med Phys,2010,12(1):3270. [3] 刘利彬,吴君心,瞿宜艳,等.应用CBCT研究胸腹部肿瘤IMRT两种体位固定技术的摆位误差[J].中华放射肿瘤学杂志,2014,23(1):48-52.DOI:10.3760/cma.j.issn.1004-4221.2014.01.013. Liu LB,Wu JX,Qu YY,et al. Study the setup errors by CBCT in radiotherapy with two different immobilization techniques for thoracic and abdominal tumors[J].Chin J Radiat Oncol,2014,23(1):48-52.DOI:10.3760/cma.j.issn.1004-4221.2014.01.013. [4] Guckenberger M,Meyer J,Vordermark D,et al. Magnitude and clinical relevance of translational and rotational patient setup errors:a cone-beam CT study[J].Int J Radiat Oncol Biol Phys,2006,65(3):934-942. [5] 林霞,王嘉鹏,郭杰,等.真空垫与热塑体模在宫颈癌放疗中摆位误差比较[J].中国老年学杂志,2012,32(22):5009-5010.DOI:10.3969/j.issn.1005-9202.2012.22.077. Lin X,Wang JP,Guo J,et al. Comparison of the position error between the vacuum mat and the thermoplastic model in the radiotherapy of cervical cancer[J].Chin J Gerontol,2012,32(22):5009-5010.DOI:10.3969/j.issn.1005-9202.2012.22.077.