[an error occurred while processing this directive] | [an error occurred while processing this directive]
Effect of amplitude of respiratory movements on dose distribution of static intensity-modulated radiotherapy
Liu Lingling,Fei Zhenle,Li Bingbing,Wang Hongzhi
Cancer Hospital,Hefei Institutes of Physical Science,Chinese Academy of Sciences,Hefei 230031,China (Liu LL,Li BB,Wang HZH);Center of Radiotherapy,105th Hospital of Liberation Army,Hefei 230031,China (Fei ZL)
AbstractObjective To study the effect of amplitude of respiratory movements on dose distribution of static intensity-modulated radiotherapy (IMRT), and to provide a basis for dose correction against respiratory movements. Methods A two-dimensional matrix driven by the QUASAR program-controlled respiratory movement instrument was used to simulate human respiratory movements in the head/foot direction. The dose distribution was evaluated on the isocenter plane with different amplitudes of respiratory movements. The Verisoft software and absolute dose analysis were used to analyze dose distribution, percentage errors of absolute dose, and passing rates of radiation field for both collected data and planned dose distribution. Results In spite of little effect on dose distribution in target volume, respiratory movements increased the dose outside the marginal target volume along the movement direction. When the respiratory amplitude was lower than 6 mm, the passing rate of γ distribution met the requirement of clinical dose verification;when the respiratory amplitude was larger than 8 mm, the passing rate of γ distribution was reduced with the increasing respiratory amplitude and fell below the clinical standard. Conclusions Respiratory movements have a blurring effect on static IMRT. It is possible to introduce some compensation methods to static IMRT in the treatment of tumor with periodic respiratory movements. The normal tissue at the edge of target volume along the respiratory movement direction is exposed to a higher radiation dose than expected. Therefore, the radiation dose for the normal tissue around target volume should be made as low as possible in the radiotherapy plan. For the patients with relatively large respiratory amplitude, action should be taken to lower respiratory amplitude and elevate the radiation dose in target volume.
Liu Lingling,Fei Zhenle,Li Bingbing et al. Effect of amplitude of respiratory movements on dose distribution of static intensity-modulated radiotherapy[J]. Chinese Journal of Radiation Oncology, 2016, 25(5): 508-512.
Liu Lingling,Fei Zhenle,Li Bingbing et al. Effect of amplitude of respiratory movements on dose distribution of static intensity-modulated radiotherapy[J]. Chinese Journal of Radiation Oncology, 2016, 25(5): 508-512.
[1]费振乐,牛振洋,李志杰,等.模拟呼吸运动对三维放疗剂量分布的影响[J].中华放射肿瘤学杂志,2012,21(6):554-556.DOI:10.3760/cma.j.issn.1004-4221.2012.06.021. Fei ZL,Niu ZY,Li ZJ,et al. Simulation of respiratory motion effect on dose distributions in three-dimensional radiotherapy[J].Chin J Radiat Oncol,2012,21(6):554-556.DOI:10.3760/cma.j.issn.1004-4221.2012.06.021. [2]张丹丹.呼吸运动对靶区受照剂量分布影响的研究[D].北京:北京协和医学院,中国医学医科学院,2009. Zhang DD.The study of the influence of respiratory motion on target dose distribution[D].Beijing:Peking Union Medical College,Chinese Academy of Medical Sciences,2009. [3]ICRU 62号报告:光子束放疗的处方、记录和报告(补充ICRU50号报告)[R].1999.Prescribing,recording and reporting photo beam therapy (Supplement to ICRU Report 50)[R].1999. [4]孟慧鹏,孙小喆.剂量率和准直器角度对二维电离室矩阵IMRT验证Gamma通过率的影响[J].中国医学物理学杂志,2014,31(1):4608-4611. Meng HP,Sun XZ.The effect to gamma pass rates of dose rate and collimator angle during the 2D chamber array IMRT verification[J].Chin J Med Phys,2014,31(1):4608-4611. [5]Ezzell GA,Burmeister JW,Dogan N,et al. IMRT commissioning:multiple institution planning and dosimetry comparisons,a report from AAPM task group 119[J].Med Phys,2009,36(11):5359-5373.DOI:10.1118/1.3238104. [6]曹午飞,黄晓延,孙文钊,等.剂量分布验证中分辨率对Gamma通过率的影响[J].中华放射肿瘤学杂志,2012,21(2):172-175.DOI:10.3760/cma.j.issn.1004-4221.2012.02.023. Cao WF,Huang XY,Sun WZ,et al. The impact of resolution to Gamma pass rate in the verification of dose distribution[J].Chin J Radiat Oncol,2012,21(2):172-175.DOI:10.3760/cma.j.issn.1004-4221.2012.02.023. [7]易金玲,金献测,周永强,等.鼻咽癌IMRT与VMAT治疗的计划与剂量验证比较研究[J].中国医学物理学杂志,2013,30(1):3859-3865.DOI:10.3969/j.issn.1005-202X.2013.01.006. Yi JL,Jin XC,Zhou YQ,et al. Comparative study on the planning and dosimetric verification of IMRT and VMAT in the treatment of nasopharyngeal arcinoma[J].Chin J Med Phys,2013,30(1):3859-3865.DOI:10.3969/j.issn.1005-202X.2013.01.006. [8]D′souza WD,Naqvi SA,Yu CX.Real-time intra-fraction-motion tracking using the treatment couch:a feasibility study[J].Phys Med Biol,2005,50(17):4021-4033.DOI:10.1088/0031-9155/50/17/007. [9]李宝生,尹勇,辜嘉.应用快速CT扫描对肺癌运动的研究[J].东南大学学报(自然科学版),2003,33(6):728-730.DOI:10.3321/j.issn:1001-0505.2003.06.012. Li BS,Yin Y,Gu J.Research on motion of lung cancer with fast CT scan[J].J Southeast Univ (Nat Sci Ed),2003,33(6):728-730.DOI:10.3321/j.issn:1001-0505.2003.06.012. [10]阮长利,宋启斌,徐利明,等.模拟呼吸运动对肿瘤三维技术放疗的剂量分布影响[J].中华放射肿瘤学杂志,2014,23(5):418-421.DOI:10.3760/cma.j.issn.1004-4221.2014.05.014. Ruan CL,Song QB,Xu LM,et al. Simulafion of respiratory motion effect on dose distributions in three-dimensional radiotherapy of tumor[J].Chin J Radiat Oncol,2014,23(5):418-421.DOI:10.3760/cma.j.issn.1004-4221.2014.05.014. [11]肖锋,谭丽娜,孙晓欢,等.呼吸运动对肺癌动态IMRT剂量分布的影响[J].现代肿瘤医学,2012,20(3):608-611.DOI:10.3969/j.issn.1672-4992.2012.03.53. Xiao F,Tan LN,Sun XH,et al. Influence of respiratory motion on the dose distribution in dynamic intensity-modulated radiotherapy for lung cancer[J].J Mod Oncol,2012,20(3):608-611.DOI:10.3969/j.issn.1672-4992.2012.03.53. [12]李宝生,李大坤,王玉宝,等.呼吸运动对IMRT影响的实验研究[J].肿瘤防治杂志,2004,11(12):1295-1298.DOI:10.3969/j.issn.1673-5269.2004.12.018. Li BS,Li DK,Wang YB,et al. Study on effects of respiration to intensity modulated radiotherapy[J].Chin J Cancer Prev Treat,2004,11(12):1295-1298.DOI:10.3969/j.issn.1673-5269.2004.12.018.