中华放射肿瘤学杂志
Wednesday, Apr. 16, 2025   Home | Journal | Editorial | Instruction | Subscription | Advertisement | Academic | Index-in | Contact Us | Chinese
Chinese Journal of Radiation Oncology  2014, Vol. 23 Issue (6): 513-514    DOI: 10.3760/cma.j.issn.1004-4221.2014.06.014
Physics·Biology·Technique Current Issue| Next Issue| Archive| Adv Search [an error occurred while processing this directive] | [an error occurred while processing this directive]
Effect of the setup error on the dosimetric verification for the volumetric modulated arc therapy
Sun Xiaohuan, Tan Lina, Ma Kui, Xiao Feng.
Department of Radiation Oncology, Xijing Hospital, Fourth Military Medical University, Xi′an 710032,China
Download: PDF (0 KB)   HTML (1 KB) 
Export: BibTeX | EndNote (RIS)      Supporting Info
Abstract  Objective To evaluate the effect of the setup error on the dosimetric verification for the nasopharyngeal carcinoma patients and cervical carcinoma patients treated with volumetric modulated arc therapy (VMAT). Methds VMAT plans for 10 cervical cancer patients and 10 nasopharyngeal carcinoma patients were transplanted into the Delta4 phantom and calculate the dose,next,implement the treatment on the Varian iX linear accelerator. on the Varian iX linear accelerator. To simulate the setup error by moving the treatment couch in, out, up, down, left, right by 3 mm,5 mm,7 mm. Thereby study the effect of the setup error on the pass rate of the dose verification. Results The results for the dose distribution using the gamma evaluation method showed that the pass rate (3%/3 mm) was less than 90% when the setup error were greater than 3 mm and 5 mm for the nasopharyngeal carcinoma patients and the cervical carcinoma patients. The pass rate of head direction were (64.7±8.2)% and (63.3±3.6)% on setup error of 5 mm and 7 mm for nasopharyngeal carcinoma patients and cervical carcinoma patients, respectively. Conclusions Setup error has great effect on the dose verification of the VMAT plans, the greater of the setup error, the lower of the pass rate. The setup error of head direction is more sensitive than other directions especially.
Service
E-mail this article
Add to my bookshelf
Add to citation manager
E-mail Alert
RSS
Articles by authors
Sun Xiaohuan
Tan Lina
Ma Kui
Xiao Feng.
Key words Volumetric modulated arc therapy      Setup error      Dosimetric verification     
Received: 09 September 2013     
Corresponding Authors: Xiao Feng, Email:xiaofeng@fmmu.edu.cn   
Cite this article:   
Sun Xiaohuan,Tan Lina,Ma Kui et al. Effect of the setup error on the dosimetric verification for the volumetric modulated arc therapy[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 513-514.
Sun Xiaohuan,Tan Lina,Ma Kui et al. Effect of the setup error on the dosimetric verification for the volumetric modulated arc therapy[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 513-514.
URL:  
http://journal12.magtechjournal.com/Jweb_fszlx/EN/10.3760/cma.j.issn.1004-4221.2014.06.014     OR     http://journal12.magtechjournal.com/Jweb_fszlx/EN/Y2014/V23/I6/513
  Copyright © 2010 Editorial By Chinese Journal of Radiation Oncology
Support by Beijing Magtech Co.ltd  support@magtech.com.cn