AbstractObjective To evaluate the effect of carbon fiber couch on dose distribution of radiotherapy planning and verification pass rate. Methds Establishing the carbon fiber treatment couch model in Pinnacle8.0m Treatment Planning system (TPS), and then this model was used to correct dose calculations of oblique fields in the treatment plans of 10 cases of nasopharyngeal carcinoma, 10 cases of breast cancer and 10 cases of lung cancer and evaluate the effect of carbon fiber couch on the whole dose distribution of the plans. Then these plans were measured by three-dimensional dose verification equipment Delta4 to confirm the improvement extent of Gamma pass rate after considering the carbon fiber treatment couch. Results For the majority of plans, when the carbon fiber couch was taken into consideration, the target doses was significantly reduced (4772 cGy-7266 cGy vs.4859 cGy-7347 cGy, P=0.000-0.002) and the relative deviation of D95 was 1% to 3%.Measurement results of Delta4 showed that Gamma pass rate (3 mm/3% criteria) increased in all plans (96.4%-98.8% vs.93.4%-97.3%,P=0.000), some of that were up to 5 percentage when the couch model was applied. Conclusions Target doses will be overestimated if the treatment couch is ignored in TPS measurement., However it should arouse enough attention when the disease with smaller doses corresponding gradient.
Fu Qingguo,Zhu Xiaodong,Yang Haiming et al. The effect of carbon fiber couch on dose distribution of conformal intensity modulated plan[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 505-508.
Fu Qingguo,Zhu Xiaodong,Yang Haiming et al. The effect of carbon fiber couch on dose distribution of conformal intensity modulated plan[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 505-508.
[1] Gerig LH, Niedbala M, Nyiri BJ. Dose perturbations by two carbon fiber treatment couches and the ability of a commercial treatment planning system to predict these effects[J].Med Phys,2010,37:322-328. [2] 沙翔燕,王运来,廖雄飞,等.全碳素纤维治疗床对吸收剂量的影响[J].中华放射肿瘤学杂志,2008,17:223-225. [3] 鞠永健,陈关华,汤娅红,等.加速器治疗床对不同角度射野吸收剂量的影响[J].中华放射医学与防护杂志,2008,28:375-376. [4] 甘家应,胡银祥,洪卫,等.Elekta 直线加速器全碳纤维六维治疗床床板对后斜野放疗剂量的影响[J].中国肿瘤,2010,19:511-513. [5] Poppe B, Chofor N, Ruhmann A, et al. The effect of a carbon-fiber couch on the depth-dose curves and transmission properties for megavoltage photon beams[J]. Strahlenther Onkol,2007,183:43-48. [6] Mihaylov IB, Corry P, Yan Y, et al. Modeling of carbon fiber couch attenuation properties with a commercial treatment planning system[J].Med Phys,2008,35:4982-4988. [7] Vanetti E, Nicolini G, Clivio A, et al. The impact of treatment couch modelling on RapidArc[J]. Phys Med Biol,54:157-166. [8] Spezi E, Angelinia AL, Romani F, et al. Evaluating the influence of the Siemens IGRT carbon fiber tabletop in head and neck IMRT[J].Radiother Oncol,2008,89:114-122. [9] 胡逸民.靶区剂量的确定和对剂量准确性的要求[A]//胡逸民.肿瘤放射物理学[M].原子能出版社,1999:614.