AbstractObjective To investigate reasonable method of deciding internal target volume (ITV) by comparing physical phantom volumes (including moving volume) with reconstruction volumes of spiral CT scanning. Methds The various-volume wax blocks which were labeled No.1-9 were made and put on the respiratory motion simulator. The range of motion was set 2.5 cm and frequency 18 beats/min. All blocks were scanned 10 times continuously and imported into the Eclipse TPS. All blocks volumes were calculated and then compared with the true physical volumes and paired t-test. Results The reconstruction volumes of 1-9 blocks were bigger than their stationary volumes (121.77 cm3vs. 103.14 cm3,P=0.038), but significantly smaller than their moving volumes (121.77 cm3vs.161.75 cm3,P=0.045). The results can be gotten in different volume block scanning. The relative deviation of reconstruction volumes and the moving volumes tends to increase as the stationary physical volume decreases. Conclusions As to moving targets, conventional spiral CT scanning speed is too fast to collect all volume information of targets. So the one-time-scanning volume does not represent the ITV.
. A phantom study for the reconstruction defects of moving target volume decision by spiral CT[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 530-534.
. A phantom study for the reconstruction defects of moving target volume decision by spiral CT[J]. Chinese Journal of Radiation Oncology, 2014, 23(6): 530-534.
[1] 祁振宇,黄劭敏,邓小武.放疗计划CT值的校准检测及其影响因素分析[J].癌症,2006,251:110-114. [2] Mori S, Kanematsu N, Mizuno H, et al. Physical evaluation of CT scan methods for radiation therapy planning:comparison of fast, slow and gating scan using the 256-detector row CT scanner[J]. Phys Med Biol,2006,51:587-600. [3] Henley SJ, Richards TB, Underwood JM,et al. Lung cancer incidence trends among men and women-United States,2005—2010[J]. MMWR Morb Mortal Wkly Rep,2014,63:1-5. [4] Youlden DR, Cramb SM, Baade PD. The international epidemiology of lung cancer:geographical distribution and secular trends[J]. J Thorac Oncol,2008,3:819-831. [5] Cooper S, Spiro SG. Small cell lung cancer:treatment review[J]. Respirology,2006,11:241-248. [6] Chi A, Tomé WA, Fowler J, et al. Stereotactic body radiation therapy in non-small-cell lung cancer:linking radiobiological modeling and clinical outcome[J]. Am J Clin Oncol,2011,34:432-441. [7] Underberg RW, Lagerwaard FJ, Cuijpers JP, et al. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage Ⅰ lung cancer[J]. Int J Radiat Oncol Biol Phys,2004,60:1283-1290. [8] Balter JM, Lam KL, McGinn CJ,et al. Improvement of CT-based treatment-planning models of abdominal targets using static exhale imaging[J].Int J Radiat Oncol Biol Phys,1998,41:939-943. [9] Kubo HD, Len PM, Minohara S,et al. Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center[J]. Med Phys,2000,27:346-353. [10] International commission on radiation units and measurements. ICRU-62 report. Prescribing, recording and reporting photon beam therapy (Supplement to ICRU report 50)[R].Bethesda:ICRU,1999. [11] Baker GR. Localization:conventional and CT simulation[J]. Br J Radiol,2006,79:36-49. [12] 李承军,徐利明.肺癌放疗中活动靶区常规CT定位和PET/CT定位的模体研究比较[J].中国医学物理学杂志,2011,28:2743-2749. [13] 王建华,戴建荣.利用两相CT融合技术改善胸腹部肿瘤靶区勾画的初步评价[J].中华放射医学与防护杂志,2011,31:472-473. [14] 戚焕鹏,李建彬,张英杰,等.基于主动呼吸控制辅助3DCT与4DCT扫描确定周围型肺癌内大体肿瘤体积比对研究[J].中华放射医学与防护杂志,2013,33:142-145. [15] Caldwell CB, Mab K, Skinner M, et a1.Can PET provide the 3Dextent of tumor motion for individualized internal target volumes? Aphantom study of the limitations of CT and the promise of PET[J].IntJ Radiat Oncol Biol Phys,2003,55:1381,1393. [16] Vedam SS, Keall PJ, Kini VR, et a1.Acquiring a four dimensional computed tomography dataset using an externalrespiratory signal[J].Phys Med Biol,2003,48:45-62. [17] Keall P.4-dimensional computed tomography imaging and treatment planning[J].Semin Radiat Oncol,2004,14:81-90. [18] Keall PJ, Starksehall G, Shukla H, et a1.Acquiring 4D thoracic CT scans using a muhislice helical method[J].Phys Med Biol,2004,49:2053-2067. [19] James S, Mishra P, Hacker F, et al. Quantifying ITV instabilities arising from 4DCT:a simulation study using patient data[J].Phys Med Biol,2012,57:1-7. [20] Underberg RW, Lagerwaard FJ, Cuijpers JP, et al. Four-dimensional CT scans for treatment planning in stereotactic radiotherapy for stage Ⅰ lung cancer[J]. Int J Radiat Oncol Biol Phys,2004,60:1283-1290. [21] Lagerwaard FJ, Van Sornsen de Koste JR, Nijssen-Visser MR, et al.Multiple"slow" CT scans for incorporating lung tumormobility in radiotherapy planning[J].Int J Radiat Oncol Biol Phys,2001,5l:932-937.