Abstract Objective To study the dosimetry characteristics of VMAT plan in the esophageal carcinoma radiotherapy. Methods Application of 0.6 cm3 ionization chamber and COMPASS three-dimensional dose verification system, 20 cases of upper and middle chest esophageal carcinoma on the VMAT plans for absolute dose and relative dose verification. Dose volume histogram (DVH) comparison treatment target, lungs, heart, and differences in the spinal cord irradiation dose and volume, and analyses γ pass rate of GTV, CTV, PTV and organs at risks. Results The center dose of upper and middle chest esophageal carcinoma accurate rates were above 99%. Thoracic segment esophageal:GTV, PTV and organs at risks of γ pass rate above 97%. D95% and Dmean of GTV, CTV and PTV were relatively undervalued within 3%. D1% of spinal cord is 2.21% overvalued. Left and right pulmonary V5 were slightly overvalued by about 0.5%, V10—D30, Dmean undervalued within 2%. In period of middle chest esophageal carcinoma:the gamma passed rate of GTV, CTV, PTV and organs at risks of above 97%, GTV, CTV, PTV D95%, Dmean were relatively undervalued within 2%. Spinal cord D1% is 2.04% overvalued. Left and right pulmonary V5—D30 to V10 as a trend of gradually to be underestimated, at 1.5%. Heart Dmean was undervalued by 2.68%. Conclusion VMAT technology is applicable in the chest esophageal carcinoma radiotherapy.
Li Jun*,Zhang Xizhi,Hua Wei et al. Study on dosimetric verification of VMAT treatment planning for chest esophageal carcinoma[J]. Chinese Journal of Radiation Oncology, 2014, 23(3): 259-261.
Li Jun*,Zhang Xizhi,Hua Wei et al. Study on dosimetric verification of VMAT treatment planning for chest esophageal carcinoma[J]. Chinese Journal of Radiation Oncology, 2014, 23(3): 259-261.
[1] 陈进琥,尹勇,刘同海,等.颈段食管癌固定野调强与旋转调强放疗计划比较研究[J].中华放射肿瘤学杂志,2010,19:429-435. [2] Van Benthuysen L, Hales L, Podgorsak M. Volumetric modulated arc therapy vs IMRT for the treatment of distal esophageal cancer[J]. Med Dosim,2011,36:404-409. [3] Vivekanandan N, Sriram P, Kumar SA, et al. Volumetric modulated arc radiotherapy for esophageal cancer[J].Med Dosim,2012,37:108-113. [4] Nicolini G, Ghosh-Laskar S, Shrivastava SK, et al. Volumetric modulation arc radiotherapy with flattening filter-free beams compared with static gantry IMRT and 3D conformal radiotherapy for advanced esophageal cancer:a feasibility study[J]. Int J Radiat Oncol Biol Phys,2012,84:553-560. [5] Bragg CM, Wingate K, Conway J. Clinical implications of the anisotropic analytical algorithm for IMRT treatment planning and verification[J].Radiother Oncol,2008,86:276-284. [6] Arup LR, Nahum AE, Zacharatou C, et al. The effect of different lung densities on the accuracy of various dose calculation methods:implications for tumour coverage[J]. Radiother Oncol,2009,91:405-414. [7] Rnde HS, Hoffmann L. Validation of Varian′s AAA algorithm with focus on lung treatments[J]. Acta Oncol,2009,48:209-215.