Volume and location of lumpectomy cavity delineated by metal clips and/or seroma on 4DCT for external-beam partial breast irradiation:a comparative study
DING Yun, LI Jian-bin, WANG Wei, MA Zhi-fang, XU Min, FAN Ting-yong, SHAO Qian, LIANG Chao-qian.
Department of Radiation Oncology, Shandong Tumor Hospital, Medicine and Life Sciences College of Shandong Academy of Medical Sciences,Ji′nan University, Ji′nan 250117, China
Objective To conduct a comparative study of the volume and location of the lumpectomy cavity delineated by metal clips and/or seroma on four-dimensional computed tomography (4DCT) for external-beam partial breast irradiation. Methods On 10 respiratory phases of 4DCT images with 15 breast cancer patients, gross tumor volumes (GTVS) were delineated based on the metal clips at the boundaries of surgical cavity, seroma, and metal clips plus seroma to obtain GTVC, GTVS, and GTVC+S, respectively. The volumes of GTVC, GTVS, and GTVC+S were measured, and the conformity index (CI), degree of inclusion (DI), and centroid distance between each two GTVS were calculated. One-way analysis of variance was used to compare volume and CI between GTVC, GTVS, and GTVC+S;the paired t-test was used for comparison of DI;the Pearson correlation test was used to investigate the relationship of CI and DI with centroid distance. Results The volumes of GTVC, GTVS, and GTVC+S were 23.15±13.34 cm3, 19.27±17.53 cm3, and 24.60±16.72 cm3, respectively (P=0.000). The CIs of GTVC vs GTVS, GTVC vs GTVC+S, and GTVS vs GTVC+S were 0.36±0.14, 0.60±0.14, and 0.53±0.20, respectively (P=0.000). The DI of GTVS in GTVC was significantly higher than that of GTVC in GTVS (0.67±0.21 vs 0.48±0.20, P=0.000);the DI of GTVC in GTVC+S was significantly higher than that of GTVC+S in GTVC (0.82±0.11 vs 0.71±0.19, P=0.000);the DI of GTVS in GTVC+S was significantly higher than that of GTVC+S in GTVS (0.91±0.14 vs 0.52±0.22;P=0.000). The DIs and CIs of GTVC vs GTVS, GTVC vs GTVC+S, and GTVS vs GTVC+Swere negatively correlated with their centroid distances (P=0.000 for all comparisons). Conclusions There are volume differences and spatial mismatches between the GTVS delineated based on metal clips, seroma, and metal clips plus seroma.
Corresponding Authors:
LI Jian-bin, Email:lijianbin@msn.com
Cite this article:
DING Yun,LI Jian-bin,WANG Wei et al. Volume and location of lumpectomy cavity delineated by metal clips and/or seroma on 4DCT for external-beam partial breast irradiation:a comparative study[J]. Chinese Journal of Radiation Oncology, 2013, 22(5): 361-364.
DING Yun,LI Jian-bin,WANG Wei et al. Volume and location of lumpectomy cavity delineated by metal clips and/or seroma on 4DCT for external-beam partial breast irradiation:a comparative study[J]. Chinese Journal of Radiation Oncology, 2013, 22(5): 361-364.
[1]Kirby AM, Coles CE, Yamold JR, et al. Target volume definition for external beam partial breast radiotherapy:clinical, pathological and technical studies informing current approaches, Radiother Oncol,2010,94:255-263. [2]Kader HA, Truong PT, Pai R, et al. When is CT-based postoperative seroma most useful to plan partial breast radiotherapy? Evaluation of clinical factors affecting seroma volume and clarity. Int J Radiat Oncol Biol Phys, 2008,72:1064-1069. [3]徐敏,李建彬,范廷勇,等.早期乳腺癌保乳术后部分乳腺三维适形外照射的远期观察.中华放射肿瘤学杂志,2012,21:439-442. [4]Petersen RP, Truong PT, Kader HA, et al. Target volume delineation for partial breast radiotherapy planning:clinical characteristics associated with low interobserver concordance. Int J Radiat Oncol Biol Phys,2007,69:41-48. [5]Li FX, Li JB, Zhang YJ, et al. Comparison of the planning target volume based on three-dimensional CT an four-dimensional CT images of non-small-cell lung cancer. Radiother Oncol,2011,99:176-180. [6]Tersteeg RJ, Roesink JM, Albregts M,et al. Changes in excision cavity volume:prediction of the reduction in absolute volume during breast irradiation. Int J Radiat Oncol Biol Phys,2009,74:1181-1185. [7]Hurkmans C, Admiraal M, Van der Sangen M, et al. Significance of breast boost volume changes during radiotherapy in relation to current clinical interobserver variations. Radiother Oncol,2009,90:60-65. [8]徐敏,李建彬,于志强,等.勾画标准培训对乳腺癌保乳术后放疗靶区勾画的作用.中华放射肿瘤学杂志,2012,21:534-538. [9]戚焕鹏,李建彬,张英杰,等.基于自主呼吸控制三维CT扫描分析周围型肺癌四维CT各时相大体肿瘤体积伪影.中华放射肿瘤学杂志, 2012, 21:508-512. [10]Thureau S, Oden S, Mokaouim R,et al. Assessing the contribution of a standardized method in defining the tumor bed using surgical clips in breast cancer. Cancer Radiother,2012,16:100-106. [11]Dzhugashvili M, Tournay E, Pichenot C, et al. 3D-conformal accelerated partial breast irradiation treatment planning:the value of surgical clips in the delineation of the lumpectomy cavity. Radiat Oncol,2009,4:70. [12]Cox BW, Horst KC, Thornton S,et al. Impact of increasing margin around the lumpectomy cavity to define the planning target volume for 3D conformal external beam accelerated partial breast irradiation. Med Dosim,2007,32:254-262. [13]Hepel JT, Tokita M, MacAusland SG, et al. Toxicity of three-dimensional conformal radiotherapy for accelerated partial breast irradiation. Int J Radiat Oncol Biol Phys,2009,75:1290-1296.