AbstractObjective To compare the difference between breast bracket combined with polyurethane foam and single polyurethane foam in the accuracy of immobilization, providing a better immobilization for breast cancer radiotherapy. Methods Fifty breast cancer patients who received radiotherapy in Sun Yat‐sen University Cancer Center from March 2021 to July 2021 were selected. Among them, 25 patients were immobilized with polyurethane foam (foam group), and the other 25 patients were immobilized with polyurethane foam combined with breast bracket (combination group). All patients were scanned by CBCT once a week to obtain setup errors in the SI, LR and AP directions for t‐test. The formula MPTV=2.5Σ+0.7σ was used to calculate the margin of the planning target volume(MPTV). Results The setup errors in the foam group were SI (2.0±3.26) mm, LR (0.88±2.76) mm, AP (1.22±3.55) mm, Rtn ‐0.24°±0.85°, Pitch 0.16°±1.11°, Roll ‐0.32°±1.05°, and the MPTV were 6.75 mm, 8.46 mm and 8.73 mm, respectively. The setup errors in the combination group were SI (1.0±3.01) mm, LR (0.62±2.74) mm, AP (1.82±3.21) mm, Rtn 0.64°±0.59°, Pitch 0.71°±1.22°, Roll 0.29°±0.73°, and the MPTV were 6.35 mm, 7.47 mm, and 7.61 mm, respectively. After comparing the setup errors in the three‐dimensional directions between two groups, the t value of LR, SI, AP and Rtn, Pitch, Roll was -4.304, -2.681, 1.384, and -9.457, -3.683, -5.323, respectively. And the differences in the LR, SI, Rtn, Pitch and Roll directions were statistically significant (all P<0.05). Conclusions The immobilization effect of polyurethane foam combined with breast bracket is better and the MPTV is also smaller than those of polyurethane foam alone. Therefore, it is recommended to use polyurethane foam combined with breast bracket for immobilization in breast cancer radiotherapy.
Fund:Youth Outstanding Innovation Program of Cancer Prevention and Treatment Center of Sun Yat‐sen University (PT21020101); Guangdong Medical Science and Technology Research Foundation (A2017613)
Yao Wenyan,Liu Biaoshui,Fang Jianlan et al. Breast bracket combined with polyurethane foam improves the accuracy of immobilization in breast cancer radiotherapy[J]. Chinese Journal of Radiation Oncology, 2022, 31(10): 916-921.
Yao Wenyan,Liu Biaoshui,Fang Jianlan et al. Breast bracket combined with polyurethane foam improves the accuracy of immobilization in breast cancer radiotherapy[J]. Chinese Journal of Radiation Oncology, 2022, 31(10): 916-921.
[1] 肿瘤医学论坛. 2020年全球癌症最新数据解读[J].中国肿瘤临床与康复,2021,28(3):301. Oncology Forum.Interpretation of the latest data on global cancer in 2020[J]. Chin J Clinic Oncol Rehab, 2021,28(3):301. [2] 曹毛毛, 陈万青. 中国恶性肿瘤流行情况及防控现状[J].中国肿瘤临床,2019,46(3):145-149. DOI: 10.3969/j.issn.1000-8179.2019.03.246. Cao MM, Chen WQ.Epidemiology of cancer in China and the current status of prevention and control[J].Chin J Clinic Oncol, 2019,46(3):145-149. DOI: 10.3969/j.issn.1000-8179.2019. 03.246. [3] 中国抗癌协会, 国家肿瘤临床医学研究中心(天津医科大学肿瘤医院), 郝希山等.中国女性乳腺癌筛查指南[J].中国肿瘤临床, 2019,(9)46:432‐440. China Anti‐Cancer Association, National Cancer Clinical Medicine Research Center/ Tianjin Medical University Cancer Hospital, HaoXS, et al. Breast cancer screening guideline for Chinese women[J]. Chin J Clini Oncol, 2019,(9)46:432‐440. [4] Morrow M, Strom EA, Bassett LW, et al.Standard for breast conservation therapy in the management of invasive breast carcinoma[J]. CA Cancer J Clin, 2002,52(5):277-300. DOI: 10.3322/canjclin.52.5.277. [5] 中国抗癌协会乳腺癌专业委员会. 中国抗癌协会乳腺癌诊治指南与规范(2019年版)[J].中国癌症杂志,2019,29(8):609-679. DOI: 10.19401/j.cnki.1007-3639.2019.08.009. Breast Cancer Professional Committee of China Anti‐Cancer Association. Chinese anti‐cancer association guidelines and standards for breast cancer diagnosis and treatment (2019)[J]. Chin Oncol,2019,29(8):609-679. DOI: 10.19401/j.cnki.1007-3639.2019.08.009 [6] 曹井丽, 高文超, 秦琪, 等. 不同体位固定方式对乳腺癌放疗摆位精度的影响[J].现代肿瘤医学,2021,29(3):507-511. DOI: 10.3969/j.issn.1672-4992.2021.03.032. Cao JL, Gao WC, Qin Q, et al.Effects of different fixation methods on positioning error of breast cancer radiotherapy[J]. J Modern Oncol ,2021,29(3):507-511. DOI: 10.3969/j.issn.1672-4992.2021.03.032. [7] Nestle U, Schimek-Jasch T, Kremp S, et al.Imaging-based target volume reduction in chemoradiotherapy for locally advanced non-small-cell lung cancer (PET-Plan): a multicentre, open-label, randomised, controlled trial[J]. Lancet Oncol, 2020,21(4):581-592. DOI: 10.1016/S1470-2045(20)30013-9. [8] van Herk M, Remeijer P, Lebesque JV. Inclusion of geometric uncertainties in treatment plan evaluation[J]. Int J Radiat Oncol Biol Phys, 2002,52(5):1407-1422. DOI: 10.1016/s0360-3016(01)02805-x. [9] 吴志勤, 余建义, 阎华伟, 等. 锥形束CT引导下乳腺癌保乳术后调强放疗摆位误差及配准方式分析[J].中国全科医学,2017,20(15):1903-1905,1910. DOI: 10.3969/j.issn.1007-9572.2017.15.023. Wu ZQ, Yu JY, Yan HW, et al.Setup Errors and registration algorithm of intensity modulated radiation therapy after breast conserving surgery of breast cancer based on cone-beam CT[J]. Chinese General Practice,2017,20(15):1903-1905,1910. DOI: 10.3969/j.issn.1007-9572.2017.15.023. [10] 黄小琪, 曾碧丽, 陈丽民. 臂托联合真空负压垫与乳腺托架在乳腺癌术后放射治疗中的应用价值[J].医疗装备,2021,34(9):14-16. DOI: 10.3969/j.issn.1002-2376.2021.09.005. Huang XQ, Zeng BL, Chen LM.Application value of arm support combined with vacuum negative pressure pad and breast bracket in postoperative radiotherapy of breast cancer[J]. Medical Equipment,2021,34(9):14-16. DOI: 10.3969/j.issn.1002-2376.2021.09.005. [11] 徐子海, 童蕾, 陈磊, 等. 基于CTVision图像引导的乳腺癌术后患者调强放疗摆位误差测量与分析[J].中国医学物理学杂志,2015,(6)DOI: 10.3969/j.issn.1005-202X.2015.06.023. Xu ZH, Tong L, Chen L, et al.Measurement and analysis of patients' set-up errors in CTVision images-guided radiotherapy after breast cancer operation[J].Chin J Med Phys,2015,(6)DOI: 10.3969/j.issn.1005-202X.2015.06.023. [12] Zhou J, Li S, Ye C, et al.Analysis of local setup errors of sub-regions in cone-beam CT-guided post-mastectomy radiation therapy[J]. J Radiat Res, 2020,61(3):457-463. DOI: 10.1093/jrr/rraa007. [13] 李俊禹, 杜乙, 周舜, 等. OSMS在乳腺癌术后放疗临床应用中体位固定方式优选研究[J].中国医疗设备,2021,36(4):45-49. DOI: 10.3969/j.issn.1674-1633.2021.04.011. Li JY, Du Y, Zhou S, et al.Study on optimal postural immobilization method of OSMS in clinical application of postoperative radiotherapy for breast cancer[J]. China Medical Devices,2021,36(4):45-49. DOI: 10.3969/j.issn.1674-1633. 2021.04.011. [14] 屈超, 尼加提·阿卜杜热伊木, 哈尼克孜·奴尔买买提, 等. 改良头颈肩热塑体膜固定下乳腺癌改良根治术后调强放疗中的摆位误差分析[J].中华放射医学与防护杂志,2020,40(7):529-535. DOI: 10.3760/cma.j.issn.0254-5098.2020.07.007. Qu C, Nijiati·Abudureyimu, Hanikezi·Nuermaimaiti, et al. Positioning error analysis of intensity modulated radiation therapy after modified radical mastectomy for breast cancer patients with modified head neck and shoulder thermoplastics mask[J].Chin J Radiol Med Protec,2020,40(7):529-535. DOI: 10.3760/cma.j.issn.0254-5098.2020.07.007. [15] 梁锋攀, 李业居, 宁金标, 等. 体位固定对乳腺癌全切术与保乳术后放射治疗中摆位精度的影响[J].医疗装备,2017,30(15):29-30. DOI: 10.3969/j.issn.1002-2376.2017.15.019. Liang FP, Li YJ, Ning JB.Influence of postural fixation on positioning accuracy in total breast cancer resection and radiotherapy after breast conserving surgery[J]. Medical Equipment, 2017,30(15):29-30. DOI: 10.3969/j.issn.1002- 2376.2017.15.019. [16] 罗焕丽, 彭海燕, 靳富, 等. Catalyst系统在乳腺癌患者放疗摆位应用及影响因素分析[J].中华放射肿瘤学杂志,2018,27(2):190-194. DOI: 10.3760/cma.j.issn.1004-4221.2018. 02.014. Luo HL, Peng HY, Jin F, et al.Catalyst system in patient positioning during breast cancer radiotherapy: clinical application and influencing factors[J]. Chin J Radiat Oncol,2018,27(2):190-194. DOI: 10.3760/cma.j.issn.1004-4221. 2018.02.014. [17] 许森奎, 姚文燕, 胡江, 等. 鼻咽癌发泡胶个体化塑形与标准化头枕放疗体位固定精确度比较[J].中华放射肿瘤学杂志,2015,24(2):196-199. DOI: 10.3760/cma.j.issn.1004-4221. 2015.02.022. Xu SK, Yao WY, Hu J, et al.The research of accuracy immobilized using individualized polyurethane scaling agent compared to positioning foam with standard plastics pillow in the radiotherapy of nasopharyngeal carcinoma[J].Chin J Radiat Oncol,2015,24(2):196-199. DOI: 10.3760/cma.j.issn.1004- 4221.2015.02.022. [18] 张英婷, 刘炳忠, 陈文芬, 等. 聚氨酯发泡胶结合翼板个体化塑形与负压真空袋固定肺癌放疗摆位精度比较[J].中华放射肿瘤学杂志,2018,(3)DOI: 10.3760/cma.j.issn.1004-4221. 2018.03.014. Zhang YT, Liu BZ, Chen WF, et al.Comparison of positioning accuracy between personalized polyurethane foam with wing boards and negative pressure vacuum bag in radiotherapy for lung cancer[J].Chin J Radiat Oncol,2018,(3)DOI: 10.3760/cma.j.issn.1004-4221.2018.03.014. [19] 吴佳蔚, 齐新宇, 宋心愿, 等. 乳腺癌放疗中两种体位固定技术的应用比较[J].现代医用影像学,2020,29(10):1966-1969. Wu JW, Qi XY, Song XY, et al.Comparison of two postural fixation techniques in breast cancer radiotherapy[J].Modern Med Imagel,2020,29(10):1966-1969. [20] Shen K, Xiong J, Wang Z, et al.Design of a new breast vacuum bag to reduce the global and local setup errors and to reduce PTV margin in post-mastectomy radiation therapy[J]. J Radiat Res, 2020,61(6):985-992. DOI: 10.1093/jrr/rraa066. [21] 商在春, 储开岳, 葛彬彬, 等. 3种不同体位固定方式对乳腺癌调强放射治疗摆位误差影响[J].生物医学工程与临床,2021,25(4):415-420. DOI: 10.13339/j.cnki.sglc.20210615.002. Shang ZC, Chu KY, Ge BB, et al.Effects of 3 different fixation methods on setup errors in intensity-modulated radiotherapy for breast cancer[J].Biomed Eng Clini Med,2021,25(4):415-420. DOI: 10.13339/j.cnki.sglc.20210615.002. [22] 汤艳萍, 李令建. 乳腺癌保乳术后调强放射治疗在CT图像引导下的摆位误差分析[J].中国医疗设备,2017,32(1):87-89.DOI: 10.3969/j.issn.1674-1633.2017.01.023. Tang YP, Li LJ.Analysis of setup error of intensity-modulated radiation therapy guided by CT images after breast-conserving surgery for breast cancer[J]. China Medical Devices,2017,32(1):87-89.DOI: 10.3969/j.issn.1674-1633.2017.01.023. [23] 中国抗癌协会乳腺癌专业委员会. 中国抗癌协会乳腺癌诊治指南与规范(2019年版)[J].中国癌症杂志,2019,29(8):609-679. DOI: 10.19401/j.cnki.1007-3639.2019.08.009. Breast Cancer Professional Committee of China Anti‐Cancer Association. Guidelines and norms for diagnosis and treatment of breast cancer of China anti‐cancer association (2019)[J]. Chin J Cancer,2019,29(8):609-679. DOI: 10.19401/j.cnki. 1007-3639.2019.08.009.