AbstractObjective To propose a method of image similarity measurement based on structure information and intuitionistic fuzzy set and measure the similarity between CT image and CBCT image of radiotherapy plan positioning, aiming to objectively measure the setup errors. Methods A total of four pre-registration images of a nasopharyngeal carcinoma patient on the cross-sectional and sagittal planes and a pelvic tumor patient on the cross-sectional and coronal planes were randomly selected. Five methods were used to quantify the setup errors, including correlation coefficient, mean square error, image joint entropy, mutual information and similarity measure method. Results All five methods could describe the deviation to a certain extent. Compared with other methods, the similarity measure method showed a stronger upward trend with the increase of errors. After normalization, the results of five types of error increase on the cross-sectional plane of the nasopharyngeal carcinoma patient were 0.553, 0.683, 1.055, 1.995, 5.151, and 1.171, 1.618, 1.962, 1.790, 3.572 on the sagittal plane, respectively. The results of other methods were between 0 and 2 after normalization, and the results of different errors of the same method slightly changed. In addition, the method was more sensitive to the soft tissue errors. Conclusions The image similarity measurement method based on structure information and intuitionistic fuzzy set is more consistent with human eye perception than the existing evaluation methods. The errors between bone markers and soft tissues can be objectively quantified to certain extent. The soft tissue deviation reflected by the setup errors is of significance for individualized precision radiotherapy.
Corresponding Authors:
Deng Yongjin, Email:dengyj27@mail.sysu.edu.cn
Cite this article:
Zhong Jiajian,Qiu Minmin,Huang Taiming et al. Application of image similarity measure based on structure information and intuitionistic fuzzy set in radiotherapy setup verification[J]. Chinese Journal of Radiation Oncology, 2021, 30(9): 936-941.
Zhong Jiajian,Qiu Minmin,Huang Taiming et al. Application of image similarity measure based on structure information and intuitionistic fuzzy set in radiotherapy setup verification[J]. Chinese Journal of Radiation Oncology, 2021, 30(9): 936-941.
[1] 钟嘉健,王成涛,邓永锦,等.OBI图像引导在鼻咽癌IMRT中的应用[J]. 中华放射肿瘤学杂志,2017, 26(9):992-996.DOI:10.3760/cma.j.issn.1004-4221.2017.09.003. Zhong JJ, Wang CT, Deng YJ, et al.Application of OBI system in intensity-modulated radiotherapy for nasopharyngeal carcinoma[J]. Chin J Radiat Oncol, 2017, 26(9):992-996.DOI:10.3760/cma.j.issn.1004-4221.2017.09.003. [2] Ahn PH, Chen CC, Ahn AI, et al.Adaptive planning in intensity-modulated radiation therapy for head and neck cancers:single-institution experience and clinical implications[J]. Int J Radiat Oncol Biol Phys, 2011, 80(3):677-685.DOI:10.1016/j.ijrobp.2010.03.014. [3] Park SS, Yan D, McGrath S, et al.Adaptive image-guided radiotherapy (IGRT) eliminates the risk of biochemical failure caused by the bias of rectal distension in prostate cancer treatment planning:clinical evidence[J]. Int J Radiat Oncol Biol Phys, 2012, 83(3):947-952.DOI:10.1016/j.ijrobp.2011.08.025. [4] 张蔚,许青,柯桂好,等.术前术后宫颈癌膀胱充盈度一致性在调强放疗中对靶区及危及器官重要性研究[J]. 中华放射肿瘤学杂志,2019, 28(6):438-441.DOI:10.3760/cma.j.issn.1004-4221.2019.06.009. Zhang W, Xu Q, Ke GH, et al.Study on the significance of consistency of preoperative and postoperative bladder filling in patients with cervical cancer for target area and organ at risk in IMRT[J]. Chin J Radiat Oncol, 2019, 28(6):438-441.DOI:10.3760/cma.j.issn.1004-4221.2019.06.009. [5] Boda-Heggemann J, Lohr F, Wenz F, et al.kV cone-beam CT-based IGRT:a clinical review[J]. Strahlenther Onkol, 2011, 187(5):284-291.DOI:10.1007/s00066-011-2236-4. [6] Hamdan I, Bert J, Rest CCL, et al.Fully automatic deformable registration of pretreatment MRI/CT for image-guided prostate radiotherapy planning[J]. Med Phys, 2017, 44(12):6447-6455.DOI:10.1002/mp.12629. [7] Xu L, Yan Q, Xia Y, et al.Structure extraction from texture via relative total variation[J]. ACM Trans Graph, 2012, 31(6):1-10.DOI:10.1145/2366145.2366158. [8] Ding L, Goshtasby A.On the Canny edge detector[J]. Patt Recog, 2001, 34(3):721-725.DOI:10.1016/s0031-3203(00)00023-6. [9] Atanassov KT.Intuitionistic fuzzy sets theory and applications[M]. Heidelberg:Physica-verlag, 1999.DOI:10.1007/978-94-009-4682-8. [10] Hung WL, Yang MS.Similarity measures of intuitionistic fuzzy sets based on Hausdorff distance[J]. Patt Recog Lett, 2004, 25(14):1603-1611.DOI:10.1016/j.patrec.2004.06.006. [11] 张国前,张书旭,曾庆星,等.不同配准方式下鼻咽癌千伏级CBCT图像引导放疗的摆位误差[J]. 中国医学物理学杂志,2020, 37(3):282-288.DOI:10.3969/j.issn.1005-202X.2020.03.005. Zhang GQ, Zhang SX, Zeng QX, et al.Setup error of kilovolt CBCT image guided radiotherapy for nasopharyngeal carcinoma with different registration methods[J]. Chin J Med Phys, 2020, 37(3):282-288.DOI:10.3969/j.issn.1005-202X.2020.03.005. [12] 李云,王凡.3种配准方式下肺癌图像引导放射治疗摆位误差的比较[J]. 安徽医学,2019, 40(6):603-605.DOI:10.3969/j.issn.1000-0399.2019.06.001. Li Y, Wang F.Comparison of setup errors of three registration methods in image-guided radiotherapy for lung cancer[J]. Anhui Med J, 2019, 40(6):603-605.DOI:10.3969/j.issn.1000-0399.2019.06.001. [13] 徐少平,张华,江顺亮,等.基于直觉模糊集的图像相似性度量[J]. 模式识别与人工智能,2009, 22(1):156-161.DOI:10.3969/j.issn.1003-6059.2009.01.024. Xu SP, Zhang H, Jiang SL, et al.Image similarity measurement based on intuitionistic fuzzy sets[J]. Patt Recog Artif Intell, 2009, 22(1):156-161.DOI:10.3969/j.issn.1003-6059.2009.01.024. [14] 史小雨.基于SIFT特征和结构相似性的图像质量评价[D]. 大连:大连理工大学,2013. Shi XY.Image quality assessment based on SIFT feature and structural similarity[D]. Dalian:Dalian University of Technology, 2013. [15] 高振宇,杨晓梅,龚剑明,等.图像复杂度描述方法研究[J]. 中国图象图形学报,2010, 15(1):129-135.DOI:10.11834/jig.20100121. Gao ZN, Yang XM, Gong JM, et al.Research on image complexity description methods[J]. J Imag Graph, 2010, 15(1):129-135.DOI:10.11834/jig.20100121. [16] 唐祚.基于互信息和Demons医学图像配准的算法研究[D]. 沈阳:辽宁师范大学,2016. Tang Z.Medical image registration research based on mutual information and Demons algorithm[D]. Shenyang:Liaoning Normal University, 2016. [17] 龚洪涛.基于HVS特性的图像质量客观评价[D]. 南京:南京理工大学,2011.DOI:10.7666/d.y1918983. Gong HT.Objective evaluation of image quality based on HVS characteristics[D]. Nanjing:Nanjing University of Science and Technology, 2011.DOI:10.7666/d.y1918983. [18] 汪洋,卢焕章,孙广富.基于空间模糊化表示的图形相似性测度[J]. 系统工程与电子技术,2005, 27(2):340-342.DOI:10.3321/j.issn:1001-506X.2005.02.041. Wang Y, Lu HZ, Sun GF.Similarity measure between shapes based on spatial fuzzy representation[J]. Sys Eng Elect, 2005, 27(2):340-342.DOI:10.3321/j.issn:1001-506X.2005.02.041. [19] 方临明,颜桂明,张飞燕,等.宫颈癌放疗患者体重指数变化对摆位误差的影响[J]. 中国现代医生,2018, 56(8):28-31. Fang LM, Yan GM, Zhang FY, et al.Effect of body mass index changes on setup error in the patients with cer-vical cancer after radiotherapy[J]. Chin Mod Doct, 2018, 56(8):28-31. [20] 王锐濠,张书旭,林生趣.基于CT图像引导鼻咽癌自适应放疗研究进展[J]. 中华肿瘤防治杂志,2014, 21(7):560-564.DOI:10.3969/j.issn.1673-5269.2014.07.017. Wang RH, Zhang SX, Lin SQ.Recent advance in CT image-guided adaptive radiotherapy for nasopharyngeal carcinoma[J]. Chin J Cancer Prevent Treat, 2014, 21(7):560-564.DOI:10.3969/j.issn.1673-5269.2014.07.017.