Application of adjuvant skin-marker positioning in overweight patients with thoracic and abdominal tumors
Wu Jiandong, Chen Xiuying, Hong Jinsheng, Wu Yinghui, Chen Longjian, Huang Weikang, Xue Wangui, Wu Bin
Department of Radiation Oncology, the First Affiliated Hospital of Fujian Medical University, Key Laboratory of Radiation Biology (Fujian Medical University), Fujian Province University, Fuzhou 350005, China
AbstractObjective To investigate whether adjuvant skin-marker positioning can decrease the set-up errors in overweight patients with thoracic and abdominal tumors. Methods A total of 60 overweight patients with thoracic and abdominal tumors treated with radiotherapy in the First Affiliated of Fujian Medical University between January 2018 and December 2018 were randomly divided into two groups. In group A, conventional skin-marker positioning was adopted. In group B, conventional skin-marker positioning combined with adjuvant skin-marker position was employed. All patients were immobilized with thermoplastic positioning body membrane with head-body plate fixation. The set-up errors in the right-left, head-foot and dorsoventral directions were obtained from cone-beam CT (CBCT) scan system before radiation delivery. The set-up errors were statistically compared between two groups by using t-test. Results In group A, the set-up errors in the right-left, head-foot and dorsoventral directions were (4.47±2.91) mm,(5.43±2.61) mm and (3.87±2.40) mm, significantly higher compared with (2.97±1.68) mm,(3.21±1.62) mm and (2.59±1.57) mm, respectively (all P<0.001). Conclusion Adjuvant skin-marker positioning method can reduce the set-up errors and enhance the positioning repeatability in overweight patients with thoracic and abdominal tumors receiving radiotherapy.
Wu Jiandong,Chen Xiuying,Hong Jinsheng et al. Application of adjuvant skin-marker positioning in overweight patients with thoracic and abdominal tumors[J]. Chinese Journal of Radiation Oncology, 2020, 29(12): 1091-1095.
Wu Jiandong,Chen Xiuying,Hong Jinsheng et al. Application of adjuvant skin-marker positioning in overweight patients with thoracic and abdominal tumors[J]. Chinese Journal of Radiation Oncology, 2020, 29(12): 1091-1095.
[1] Chen WQ, Zhang RS, Baade PD, et al. Cancer statistics in China, 2015[J]. Ca Cancer J Clin,2016,66(2):115-132. DOI:10.3978/j.issn,1000-9604. 2015. 02.07. [2] 胡逸民. 治疗体位及体位同定技术[M]//殷蔚伯,余子豪,徐国镇,等. 肿瘤放射治疗学.4版. 北京:中国协和医科大学出版社,2008:95-99. Hu YM. Treatment position and posture fixation technology[M]// Yin WB, Yu ZH, Xu GZ, et al. Radiation Oncology. 4th ed. Beijing:Peking Union Medical College Press, 2008:95-99. [3] Steele CB, Thomas CC, Henley SJ, et al. Vital signs:trends in incidence of cancers associated with overweight and obesity-United States, 2005-2014[J]. MMWR Morb Mortal Wkly Rep, 2017, 66(39):1052-1058. DOI:10.15585/mmwr.mm6639e1. [4] 张大权,王建文,胡作怀,等. 真空垫和体膜固定胸腹部肿瘤放疗应用研究[J]. 中华放射肿瘤学杂志, 2017,26(11):1285-1287. DOI:10.3760/cma.j.issn.1004-4221. 2017.11.009. Zhang DQ, Wang JW, Hu ZH, et al. Application of vacuum pad and body film fixation in radiotherapy for thoracic and abdominal tumors[J]. Chin J Radiat Oncol, 2017,26(11):1285-1287. DOI:10.3760/cma.j.issn.1004-4221. 2017.11.009. [5] 中国超重/肥胖医学营养治疗专家共识编写委员会. 中国超重和肥胖医学营养治疗专家共识[J]. 中华糖尿病杂志,2016, 8(9):525-540. DOI:10.3760/cma.j.issn.1674-5809.2016.09.004. Writing committee of Chinese experts consensus on nutritional medical treatment for overweight/obesity. The consensus of Chinese experts on nutritional medical treatment for overweight and obesity[J]. Chin J Diabet Mellitus, 2016, 8(9):525-540.DOI:10.3760/cma.j.issn.1674-5809.2016.09.004. [6] 李兴德,赵瑾,张明云,等. 胸部肿瘤放疗两种体膜固定方法的摆位精度分析[J]. 中华放射肿瘤学杂志,2013,22(5):397-399. DOI:10.3760/cma.j.issn.1004-4221. 2013.05.017. Li XD, Zhao J, Zhang MY, et al. Analysis of set-up accuracy of two body membrane fixation methods in radiotherapy for thoracic neoplasms[J]. Chin J Radiat Oncol, 2013,22(5):397-399. DOI:10.3760/cma.j.issn.1004-4221. 2013.05.017. [7] 林承光. 肿瘤放射治疗技术操作规范[M]. 北京:人民卫生出版社,2019:84-91,207-210. Lin CG. Radiotherapy technology for tumor operating specification[M]. Beijing:People's Medical Publishing House. 2019:84-91,207-210. [8] 孙振球,徐勇勇. 医学统计学[M]. 第4版. 北京:人民卫生出版社,2014:574. Sun ZQ, Xu YY. Medical Statistics[M]. 4th Ed. Beijing:People's Medical Publishing House, 2014:574. [9] 李兴德,翟福山,张明云,等. 胸部肿瘤患者体重指数对摆位误差的影响[J]. 中华放射肿瘤学杂志,2015,24(1):40-41. DOI:10.3760/cma.j.issn.1004-4221.2015.01.011. Li XD, Zhai FS, Zhang MY, et al. Effects of body mass index on positioning errors in patients with thoracic neoplasms[J]. Chin J Radiat Oncol, 2015,24(1):40-41. DOI:10.3760/cma.j.issn.1004-4221.2015.01.011. [10] Zhao J, Zhang M, Zhai F, et al. Setup errors in radiation therapy for thoracic tumor patients of different body mass index[J]. J Appl Clin Med Phys, 2018,19(3):27-31. DOI:10.1002/acm2.12270. [11] Coffman A, Boothe D, Frandsen J, et al. Correlates and trends of IMRT use in locally advanced rectal cancer[J]. J Radiat Oncol, 2016:1-9. DOI:10.1007/s13566-016-0285-0. [12] 梁恒坡,韩倩,李良,等. 体质指数对肺癌患者图像引导放疗中摆位误差的影响[J]. 中国临床研究, 2017,30(3):320-322. DOI:10.13429/j.cnki.cjcr.2017.03.009. Liang HP, Han Q, Li L, et al. Effect of body mass index on setup errors in image guided radiotherapy for lung cancer patients[J]. Chin J Clin Res, 2017,30(3):220-322. DOI:10.13429/j. cnki.cjcr.2017.03.009. [13] 李明,储开岳,蔡晶,等. 改进型腹板与热塑模联合固定在直肠癌术后放疗中的应用研究[J]. 中华放射肿瘤学杂志,2013,22(1):34-35. DOI:10.3760/cma.j.issn.1004-4221.2013. 01. 010. Li M, Chu KY, Cai J, et al. Application of improved belly board in postoperative patients of rectal cancer radiotherapy[J]. Chin J Radiat Oncol, 2013,22(1):34-35. DOI:10.3760/cma.j.issn.1004-4221.2013.01.010. [14] 孔旭东,杨波,杨伟强,等. 直肠癌术后调强放疗三种不同体位固定的摆位误差及重复性比较[J]. 中国医学物理学杂志,2012, 29(6):3734-3736. DOI:10.3969/j.issn.1005-202X.2012.06.006. Kong XD, Yang B, Yang WQ, et al. Comparison of positioning error and reproducibility with three fixation techniques for IMRT in postoperative of recal cancer[J]. Chin J Med Phy, 2012, 29(6):3734-3736. DOI:10.3969/j.issn.1005-202X. 2012.06.006. [15] 景生华,杨孝伟,许诺,等.≥3个金标追踪在射波刀中的优势比较[J]. 中华放射肿瘤学杂志, 2016,25(9):968-970. DOI:10.3760/cma.j.issn.1004-4221. 2016.09.014. Jing SH, Yang XW, Xu N, et al. Advantages of tracking no less than three gold markers in radiotherapy with cyber knife[J]. Chin J Radiat Oncol,2016,25(9):968-970. DOI:10.3760/cma.j.issn.1004-4221. 2016.09.014. [16] Chen G, Dong B, Shan G, et al. Choice of immobilization of stereotactic body radiotherapy in lung tumor patient by BMI[J]. BMC Cancer, 2019,19(1):583. DOI:10.1186/s12885-019-5767-1.
[1]
Li Minghui, Niu Chuanmeng, Zhang Ke, Tian Yuan, Men Kuo, Dai Jianrong. A study on fast cone beam CT[J]. Chinese Journal of Radiation Oncology, 2020, 29(6): 461-465.