Abstract Dose-guided radiotherapy (DGRT) is a potentially useful adaptive radiotherapy method which dosimetrically compensates for interfractional non-rigid deformation. With the improvement of in-room imaging quality,development of the deformation registration algorithm and innovation of computer science,the wide application of DGRT might be realized. The purpose of this article is to briefly summarize the work flow, clinical application and prospect of DGRT.
Corresponding Authors:
Bai Sen,Email:baisen@scu.edu.cn
Cite this article:
Zhang Xiangbin,Li Guangjun,Zhang Yingjie et al. Clinical application and research progress on dose-guided radiotherapy[J]. Chinese Journal of Radiation Oncology, 2020, 29(1): 65-68.
Zhang Xiangbin,Li Guangjun,Zhang Yingjie et al. Clinical application and research progress on dose-guided radiotherapy[J]. Chinese Journal of Radiation Oncology, 2020, 29(1): 65-68.
[1]Nassef M,Simon A,Cazoulat G,et al. Quantification of dose uncertainties in cumulated dose estimation compared to planned dose in prostate IMRT[J]. Radiother Oncol,2016,119(1):129-136. DOI:10.1016/j.radonc.2016.03.007.
[2]Eminowicz G,Rompokos V,Stacey C,et al. Understanding the impact of pelvic organ motion on dose delivered to target volumes during IMRT for cervical cancer[J]. Radiother Oncol,2017,122(1):116-121. DOI:10.1016/j.radonc.2016.10.018.
[3]Tinger A,Michalski JM,Cheng A,et al. A critical evaluation of the planning target volume for 3-D conformal radiotherapy of prostate cancer[J]. Int J Radiat OncolBiolPhys,1998,42(1):213-221. DOI:10.1016/S0360-3016(98)00189-8.
[4]Dearnaley DP,Hall E,Lawrence D,et al. Phase Ⅲ pilot study of dose escalation using conformal radiotherapy in prostate cancer:PSA control and side effects[J]. Br J Cancer,2005,92(3):488-498. DOI:10.1038/sj.bjc.6602301.
[5]Keall PJ,Mageras GS,Balter JM,et al. The management of respiratory motion in radiation oncology report of AAPM Task Group 76a)[J]. Med Phys,2006,33(10):3874-3900. DOI:10.1118/1.2349696.
[6]Oldham M,Létourneau D,Watt L,et al. Cone-beam-CT guided radiation therapy:a model for on-line application[J]. Radiother Oncol,2005,75(3):271. E271-271. E278. DOI:10.1016/j.radonc.2005.03.026.
[7]Jan U,David C,Theodore H,et al. Exploiting tumor shrinkage through temporal optimization of radiotherapy[J]. Phys MedBiol,2014,59(12):3059-3079. DOI:10.1088/0031-9155/59/12/3059.
[8]Müller BS,Duma MN,Kampfer S,et al. Impact of interfractional changes in head and neck cancer patients on the delivered dose in intensity modulated radiotherapy with protons and photons[J]. Phys Med,2015,31(3):266-272. DOI:10.1016/j.ejmp.2015.02.007.
[9]Lutkenhaus LJ,Visser J,de Jong R,et al. Evaluation of delivered dose for a clinical daily adaptive plan selection strategy for bladder cancer radiotherapy[J]. Radiother Oncol,2015,116(1):51-56. DOI:10.1016/j.radonc.2015.06.003.
[10]Murphy MJ,Balter J,Balter S,et al. The management of imaging dose during image-guided radiotherapy:report of the AAPM Task Group 75[J]. Med Phys,2007,34(10):4041-4063. DOI:10.1118/1.2775667.
[11]Elstrøm UV,Wysocka BA,Muren LP,et al. Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer[J]. Acta Oncol,2010,49(7):1101-1108. DOI:10.3109/0284186X.2010.500304.
[12]Thor M,Petersen JBB,Bentzen L,et al. Deformable image registration for contour propagation from CT to cone-beam CT scans in radiotherapy of prostate cancer[J]. Acta Oncol,2011,50(6):918-925. DOI:10.3109/0284186X.2011.577806.
[13]Chen S,Le Q,Mutaf Y,et al. Feasibility of CBCT-based dose with a patient-specific stepwise HU-to-density curve to determine time of replanning[J]. J ApplClin Med Phys,2017,18(5):64-69. DOI:10.1002/acm2.12127.
[14]Fotina I,Hopfgartner J,Stock M,et al. Feasibility of CBCT-based dose calculation:Comparative analysis of HU adjustment techniques[J]. Radiother Oncol,2012,104(2):249-256. DOI:10.1016/j.radonc.2012.06.007.
[15]Rune Slot T,Uffe B,Ernesto MH,et al. Hounsfield unit recovery in clinical cone beam CT images of the thorax acquired for image guided radiation therapy[J]. Phys Med Biol,2016,61(15):5781-5802. DOI:10.1088/0031-9155/61/15/5781.
[16]Dunlop A,McQuaid D,Nill S,et al. Comparison of CT number calibration techniques for CBCT-based dose calculation[J]. Strahlenther Onkol,2015,191(12):970-978. DOI:10.1007/s00066-015-0890-7.
[17]Fan Q,Lu B,Park JC,et al. Image-domain shading correction for cone-beam CT without prior patient information[J]. J Appl Clin Med Phys,2015,16(6):65-75. DOI:10.1120/jacmp.v16i6.5424.
[18]Marchant TE,Moore CJ,Rowbottom CG,et al. Shading correction algorithm for improvement of cone-beam CT images in radiotherapy[J]. Phys Med Biol,2008,53(20):5719-5733. DOI:10.1088/0031-9155/53/20/010.
[19]Chen L,Price RA,Wang L,et al. MRI-based treatment planning for radiotherapy:dosimetric verification for prostate IMRT[J]. Int J Radiat Oncol Biol Phys,2004,60(2):636-647. DOI:10.1016/j.ijrobp.2004.05.068.
[20]Catana C,van der Kouwe A,Benner T,et al. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype[J]. J Nucl Med,2010,51(9):1431-1438. DOI:10.2967/jnumed.109.069112.
[21]Dowling JA,Lambert J,Parker J,et al. An atlas-based electron density mapping method for magnetic resonance imaging (MRI)-alone treatment planning and adaptive MRI-based prostate radiation therapy[J]. Int J Radiat Oncol Biol Phys,2012,83(1):e5-e11. DOI:10.1016/j.ijrobp.2011.11.056.
[22]Acharya S,Fischer-Valuck BW,Kashani R,et al. Online magnetic resonance image guided adaptive radiation therapy:first clinical applications[J]. Int J Radiat Oncol Biol Phys,2016,94(2):394-403. DOI:10.1016/j.ijrobp.2015.10.015.
[23]Jonas H,Philipp S,Guillaume L,et al. A novel method for interactive multi-objective dose-guided patient positioning[J]. Phys Med Biol,2017,62(1):165-185. DOI:10.1088/1361-6560/62/1/165.
[24]Andersen ES,Muren LP,Sørensen TS,et al. Bladder dose accumulation based on a biomechanical deformable image registration algorithm in volumetric modulated arc therapy for prostate cancer[J]. Phys Med Biol,2012,57(21):7089-7100. DOI:10.1088/0031-9155/57/21/7089.
[25]Chen J,Morin O,Aubin M,et al. Dose-guided radiation therapy with megavoltage cone-beam CT[J]. Br J Radiol,2006,79(Special1):S87-S98. DOI:10.1259/bjr/60612178.
[26]van Rooijen DC,van Wieringen N,Stippel G,et al. Dose-guided radiotherapy:potential benefit of online dose recalculation for stereotactic lung irradiation in patients with non-small-cell lung cancer[J]. Int J Radiat Oncol Biol Phys,2012,83(4):e557-e562. DOI:10.1016/j.ijrobp.2011.12.055.
[27]Smyth G,McCallum HM,Pearson MJM,et al. Comparison of a simple dose-guided intervention technique for prostate radiotherapy with existing anatomical image guidance methods[J]. Br J Radiol,2012,85(1010):127-134. DOI:10.1259/bjr/13032912.
[28]Hofmaier J,Haehnle J,Kurz C,et al. Multi-criterial patient positioning based on dose recalculation on scatter-corrected CBCT images[J]. Radiother Oncol,2017,125(3):464-469. DOI:10.1016/j.radonc.2017.09.020.
[29]Ahunbay EE,Peng C,Chen GP,et al. An on-line replanning scheme for interfractional variationsa)[J]. Med Phys,2008,35(8):3607-3615. DOI:10.1118/1.2952443.
[30]Mohan R,Zhang X,Wang H,et al. Use of deformed intensity distributions for on-line modification of image-guided IMRT to account for interfractional anatomic changes[J]. Int J Radiat Oncol Biol Phys,2005,61(4):1258-1266. DOI:10.1016/j.ijrobp.2004.11.033.
[31]Feng Y,Castro-Pareja C,Shekhar R,et al. Direct aperture deformation:An interfraction image guidance strategy[J]. Med Phys,2006,33(12):4490-4498. DOI:10.1118/1.2374675.
[32]Ahunbay EE,Li XA. Gradient maintenance:a new algorithm for fast online replanning[J]. Med Phys,2015,42(6Part1):2863-2876. DOI:10.1118/1.4919847.
[33]Bohoudi O,Bruynzeel AME,Senan S,et al. Fast and robust online adaptive planning in stereotactic MR-guided adaptive radiation therapy (SMART) for pancreatic cancer[J]. Radiother Oncol,2017,125(3):439-444. DOI:10.1016/j.radonc.2017.07.028.
[34]Stützer K,Jakobi A,Bandurska-Luque A,et al. Potential proton and photon dose degradation in advanced head and neck cancer patients by intratherapy changes[J]. J Appl Clin Med Phys,2017,18(6):104-113. DOI:10.1002/acm2.12189.
[35]Cheung JP,Park PC,Court LE,et al. A novel dose-based positioning method for CT image-guided proton therapy[J]. Med Phys,2013,40(5):051714-051714. DOI:10.1118/1.4801910.
[36]Zhang M,Westerly DC,Mackie TR. Introducing an on-line adaptive procedure for prostate image guided intensity modulate proton therapy[J]. Phys Med Biol,2011,56(15):4947-4965. DOI:10.1088/0031-9155/56/15/019.
[37]Thyrza J,Sebastiaan B,Steven van de W,et al. Near real-time automated dose restoration in IMPT to compensate for daily tissue density variations in prostate cancer[J]. Phys Med Biol,2017,62(11):4254-4272. DOI:10.1088/1361-6560/aa5c12.